Vari-Pass

VARI-PASS 10/12 FR (3.3/4 mm) x 54 cm ADJUSTABLE LENGTH ACCESS SHEATH (5/PK)

Registry build 21.09.26
1manufacturer
1catalogue number
1recall

Who Else Makes It

Registered in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code KNY
Manufacturer City Province Registered as Device types
Conod Medical Shuyang Co., Ltd. Shuyang Jiangsu Contract manufacturer 22

Record

Regulatory record for Vari-Pass
Listed by Gyrus Acmi, Inc., United States
FDA product code KNY
Device type Accessories, Catheter, G-U
Device class Class 2
Regulation 21 CFR 876.5130
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K123170
Record published 2017-05-11
Record revised 2025-06-11 (version 8)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging Pack of 5

Catalogue Numbers

Catalogue numbers for Vari-Pass
Catalogue number Size Status
ASV1012BX In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
UroPass Gyrus Acmi, Inc. 15
Ureteral Access Sheath with 2, 3 Fr working channels dilator, 10Frx45cm Promepla 4
Dover Cardinal Health 200, LLC 3
Silhouette® Pediatric Ureteral Stent with Urowire® Guidewire Applied Medical Resources Corp. 3
UroWire® Guidewire with SL-6® Hydrophilic Coating Applied Medical Resources Corp. 2
BI-Flex Access Sheath – 12 inner / 14 outer – Length 45cm Promepla 1
Gyrus Acmi, Inc Gyrus Acmi, Inc. 1
Acucise® Custom KIT Applied Medical Resources Corp. 1
Acucise® Procedural Pack Starter Pack Applied Medical Resources Corp. 1
Bard® “C” Clamp C.R. Bard, Inc. 1
Acucise® Procedural Pack Universal Pack C Applied Medical Resources Corp. 1
Bi-Flex Promepla 1

Showing 12 of 28. All products under Accessories, Catheter, G-U

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2011-04-15 Not classified Process control Gyrus ACMI, Inc. wants to bring a recall issue to their customers attention concerning one lot of their 25BX-PTFE Coated 3 cm Flexible Tip Guidewire. As a result of a manufacturing error in the production this lot of guidewires, some units 145 2012-08-23

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer