Merit® Kit
10 catalogue numbers from 00884450256411, listed by Merit Medical Systems, Inc., United States, under Catheter, Hemodialysis, Implanted. 2 manufacturers in China are registered for this product code.
Who Else Makes It
All of them in Guangdong. One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Turnxon Precision Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 17 |
| Haolang Technology (Foshan) Limited Corporation | Foshan | Guangdong | Contract manufacturer | 6 |
Record
| Listed by | Merit Medical Systems, Inc., United States |
|---|---|
| FDA product code | MSD |
| Device type | Catheter, Hemodialysis, Implanted |
| Device class | Class 2 |
| Regulation | 21 CFR 876.5540 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2016-09-20 |
| Record revised | 2021-10-11 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Packaging | Pack of 4, pack of 5 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 00884450256411 | Label Line 1-Custom Dialysis Kit | In distribution |
| 00884450256398 | Label Line 1-Custom Dialysis Kit | In distribution |
| 00884450256404 | Label Line 1-Custom Dialysis Kit | In distribution |
| 00884450137420 | Label Line 1-Custom Dialysis Kit | In distribution |
| 00884450137406 | Label Line 1-Custom Dialysis Kit | In distribution |
| 00884450137413 | Label Line 1-Custom Dialysis Kit | In distribution |
| 00884450137451 | Label Line 1-Custom Dialysis Kit | In distribution |
| 00884450137444 | Label Line 1-Custom Dialysis Kit | In distribution |
| 00884450137437 | Label Line 1-Custom Dialysis Kit | In distribution |
| 00884450256343 | Label Line 1-Custom Dialysis Kit | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arrow | Teleflex Medical LLC | 406 |
| Split Cath® III | Medical Components Inc | 277 |
| Palindrome | Mozarc Medical US LLC | 139 |
| Titan HD | Medical Components Inc | 75 |
| ProGuide™ | Merit Medical Systems, Inc. | 72 |
| Hemo-Flow® | Medical Components Inc | 65 |
| DuraMax® | Merit Medical Systems, Inc. | 55 |
| CentrosFLO® | Merit Medical Systems, Inc. | 51 |
| BioFlo DuraMax® | Merit Medical Systems, Inc. | 51 |
| BioFlo | Navilyst Medical, Inc. | 45 |
| DuraFlow | AngioDynamics, Inc. | 37 |
| Mahurkar | Mozarc Medical US LLC | 37 |
Showing 12 of 123. All products under Catheter, Hemodialysis, Implanted
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K151967 | 2016-04-04 |
| K141363 | 2014-06-18 |
| K090148 | 2009-04-13 |
Recalls
4 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2026-02-13 | Class I | Process control | 16F dual-valved splittable sheath introducer due to a design defect, may not split as intended, which may result in hemorrhage, foreign bodies, procedure delay, embolization/thrombosis, impaired catheter function, loss of vessel for future | 47,153 |
| 2026-02-13 | Class I | Process control | 16F dual-valved splittable sheath introducer due to a design defect, may not split as intended, which may result in hemorrhage, foreign bodies, procedure delay, embolization/thrombosis, impaired catheter function, loss of vessel for future | 131 |
| 2026-02-13 | Class I | Process control | 16F dual-valved splittable sheath introducer due to a design defect, may not split as intended, which may result in hemorrhage, foreign bodies, procedure delay, embolization/thrombosis, impaired catheter function, loss of vessel for future | 21,591 |
| 2026-02-13 | Class I | Process control | 16F dual-valved splittable sheath introducer due to a design defect, may not split as intended, which may result in hemorrhage, foreign bodies, procedure delay, embolization/thrombosis, impaired catheter function, loss of vessel for future | 35,591 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.