Stradis Medical, LLC.

Closed System Foley Catheter Insertion Tray With Pre-Connected Bag And Catheter.

Registry build 21.09.26
12manufacturers in China registered for this device type
3catalogue numbers in this listing

Who Else Makes It

Concentrated in Jiangsu (7), Zhejiang (4), Shanghai (1). 7 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code OHR
Manufacturer City Province Registered as Device types
Amsino Medical (Kunshan) Co., Ltd. Kunshan Jiangsu Contract manufacturer 53
Conod Medical Co., Limited Changshu Jiangsu Contract manufacturer 48
Conod Medical Shuyang Co., Ltd. Shuyang Jiangsu Contract manufacturer 22
Primecare Medical (Suzhou) Co., Ltd. Changshu Jiangsu Contract manufacturer 20
Suzhou Jingle Polymer Medical Apparatus Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Hangzhou Jimushi Meditech Co., Ltd. Hangzhou Zhejiang Contract manufacturer 6
Shaoxing Fuqing Health Products Co., Ltd. Shaoxing Zhejiang Contract manufacturer 3
Jiangsu NEW Pentastar Medical Products Co., Ltd. Changzhou Jiangsu Exporter 146
Sterigenics Shanghai ETO Ltd. Shanghai Shanghai Contract manufacturer 65
Changshu Rozer Sterilization Technology Co., Ltd. Changshu Jiangsu Contract manufacturer 43
Joykey Industrial (Pinghu) Limited Pinghu Zhejiang Contract manufacturer 43
Hangzhou Primecare Medical Co., Ltd. Hangzhou Zhejiang Contract manufacturer 29

Record

Regulatory record for Stradis Medical, LLC.
Listed by Stradis Healthcare, United States
FDA product code OHR
Device type Catheter Care Tray
Device class Class 2
Regulation 21 CFR 876.5130
Record published 2018-03-13
Record revised 2023-02-07 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Contains natural rubber latex
Label carries lot or batch number, expiry date
Packaging Outer box of 10, outer box of 50
Distribution end date 2023-02-06

Catalogue Numbers

Catalogue numbers for Stradis Medical, LLC.
Catalogue number Size Status
33068 Withdrawn
33066 Withdrawn
1683000-1 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Medline Medline Industries, Inc. 267
Medline Industries, Inc. Medline Industries, Inc. 75
TruAdvance™ HR Pharmaceuticals Inc. 29
Cardinal Health Cardinal Health 200, LLC 16
VaPro Plus Pocket Kit Hollister Incorporated 10
LSL Healthcare Lsl Industries, Inc. 8
Duette™ Poiesis Medical, LLC 8
Centurion Medical Products Corp Medline Industries, Inc. 6
Medical Action Industries Medical Action Industries, Inc. 5
TruCath HR Pharmaceuticals Inc. 5
McKesson Mckesson Medical-Surgical Inc. 5
Closed System Foley Catheter Tray, Pre-Connected Closed Circuit: 12 Fr Dynarex Corp. 4

Showing 12 of 42. All products under Catheter Care Tray

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of Stradis Medical, LLC.
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Stradis Healthcare UDI-DI 2022-12-15 Class II Process control Potential for the outer bag having pinhole leaks near the seal, which may result in a breach in the sterility of the kit. 920 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer