Midmark
21 catalogue numbers from 9A599001, listed by Midmark Corporation, United States, under Sterilizer, Steam. 3 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (1), Guangdong (1), Zhejiang (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Guangzhou Ajax Medical Equipment Co Ltd | Guangzhou | Guangdong | Manufacturer | 13 |
| Ningbo Ican Machines Co., Ltd. | Ningbo | Zhejiang | Manufacturer | 1 |
Record
| Listed by | Midmark Corporation, United States |
|---|---|
| FDA product code | FLE |
| Device type | Sterilizer, Steam |
| Device class | Class 2 |
| Regulation | 21 CFR 880.6880 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K163337 |
| Record published | 2019-08-01 |
| Record revised | 2021-11-24 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Over the counter | Yes |
| Supplied as a kit | Yes |
| Label carries | manufacturing date, serial number |
| Storage | Storage environment humidity 10 to 90 % RH; Storage environment temperature -30 to 60 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 9A599001 | In distribution | |
| M11-041 / 9A682001 | In distribution | |
| M9-040 / 9A599001 | In distribution | |
| M9-041 / 9A682001 | In distribution | |
| M3-042 | In distribution | |
| M3-041 | In distribution | |
| M9-040 | In distribution | |
| M9-050 | In distribution | |
| M9-040R | In distribution | |
| M9-041 | In distribution | |
| M11-040 / 9A599001 | In distribution | |
| M3-040 | In distribution | |
| M11-041 / 9A599001 | In distribution | |
| M11-040 | In distribution | |
| M9-040 / 9A682001 | In distribution | |
| M11-050 | In distribution | |
| M9-041 / 9A599001 | In distribution | |
| M11-040R | In distribution | |
| 9A401002 | In distribution | |
| M11-051 | In distribution | |
| M11-041 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Amsco | Steris Mexico, S. de R.L. de C.V. | 434 |
| Getinge 500 Series | Getinge IC Production Poland sp. z o.o. | 133 |
| Getinge 700 Series | Getinge IC Production Poland sp. z o.o. | 82 |
| Aesculap | Aesculap AG | 67 |
| Getinge 600 Series | Getinge IC Production Poland sp. z o.o. | 61 |
| Sterilizer, Steam | Steris Mexico, S. de R.L. de C.V. | 53 |
| Getinge 800 Series | Getinge IC Production Poland sp. z o.o. | 41 |
| Getinge 400 Series | Getinge IC Production Poland sp. z o.o. | 37 |
| Primus Sterilizer | Primus Sterilizer Company, LLC. | 24 |
| Bravo 17V Autoclave | Scican Ltd. | 19 |
| Atlas | Steris Mexico, S. de R.L. de C.V. | 18 |
| Bravo 21V Autoclave | Scican Ltd. | 17 |
Showing 12 of 119. All products under Sterilizer, Steam
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K233026 | 2024-04-04 |
| K163337 | 2017-08-31 |
| K090670 | 2009-07-07 |
| K023348 | 2003-03-03 |
| K992744 | 2000-01-10 |
| K990189 | 1999-04-19 |
| K936181 | 1994-11-30 |
| K911322 | 1991-08-26 |
| K900432 | 1990-07-27 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2011-10-24 | Not classified | Employee error | During and FDA inspection on 8/23/2011, it was discovered that the firm received numerous reports of the steam sterilizer malfunctioning. | 30,255 units | 2014-06-20 |
| 2003-03-05 | Not classified | Other | The pressure relief valve may fail to open properly. | 35 | 2004-01-20 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.