Argyle
Argyle Suction Tubing Integral Funnel/Funnel, Non-Conductive 9/32" x 20' (7 mm x 6.1 m)
Who Else Makes It
Concentrated in Jiangsu (13), Zhejiang (7), Guangdong (6). 12 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Gcmedica Enterprise Ltd.(Wuxi) | Wuxi | Jiangsu | Contract manufacturer | 55 |
| Flexicare Medical (Dongguan) Ltd. | Dongguan | Guangdong | Contract manufacturer | 48 |
| Well Lead Medical Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 46 |
| Suzhou Jinsheng Plastic Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Jiangsu Weikang Jiejing Medical Apparatus Co., Ltd. | Shuyang | Jiangsu | Contract manufacturer | 18 |
| Exact Medical Manufacturing, Inc. | Changzhou | Jiangsu | Contract manufacturer | 17 |
| Ningbo Shengyurui Medical Appliance Co. | Ningbo | Zhejiang | Contract manufacturer | 11 |
| Changzhou Rongxin Medicine Minimal Invasion Technology Co., Ltd. | Jintan | Jiangsu | Contract manufacturer | 10 |
| Chengdu Xinjin Shifeng Medical Apparatus & Instrument Co., Ltd. | Chengdu | Sichuan | Contract manufacturer | 10 |
| Anhui Careplus Medical Technology Co., Ltd. | Xuancheng | Anhui | Contract manufacturer | 6 |
| Dong Guan Queenmed Equipment MFG Co Ltd | Dongguan | Guangdong | Contract manufacturer | 2 |
| Suzhou Jinsheng Plastic Co., Ltd. (Zhibei Branch) | Suzhou | Jiangsu | Contract manufacturer | 2 |
Showing 12 of 33. All 33 manufacturers in China registered for Tubing, Noninvasive
Record
| Listed by | Cardinal Health 200, LLC, United States |
|---|---|
| FDA product code | GAZ |
| Device type | Tubing, Noninvasive |
| Device class | Class 2 |
| Regulation | 21 CFR 880.6740 |
| Establishment | Contract manufacturer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2024-08-19 |
| Record revised | 2024-07-19 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Over the counter | Yes |
| Label carries | lot or batch number, expiry date |
| Packaging | Case of 50, case of 5, case of 10, case of 2 |
| Sizes | Length 1.5 to 20 ft; lumen/inner diameter 5 mm; outer diameter 11 mm; lumen/inner diameter 0.19 in; outer diameter 0.28 in |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 155652 | 50 | In distribution | |
| 5558284526 | 75 | In distribution | |
| 5558284591 | 50 | In distribution | |
| 155654 | 50 | In distribution | |
| 8888301549 | In distribution | ||
| 5558284559 | 15 | In distribution | |
| 155657 | 50 | In distribution | |
| 8888284505 | Length 1.5 ft | In distribution | |
| 8888301645 | In distribution | ||
| 8888270306 | Lumen/Inner Diameter 5 mm | 100 | In distribution |
| 155653 | 100 | In distribution | |
| 8888230425 | In distribution | ||
| 439320 | 20 | In distribution | |
| 5558284732 | 30 | In distribution | |
| 8888271106 | Outer Diameter 11 mm | 100 | In distribution |
| 5558301627 | 30 | In distribution | |
| 5558301585 | 50 | In distribution | |
| 5558301726 | 30 | In distribution | |
| 155658 | In distribution | ||
| 8888301630 | In distribution | ||
| 5558284542 | 30 | In distribution | |
| 8888280214 | In distribution | ||
| 155659 | In distribution | ||
| 155655 | 50 | In distribution | |
| 8888280412 | In distribution | ||
| 5558301734 | 15 | In distribution | |
| 5558301635 | 15 | In distribution | |
| 8888301507 | Lumen/Inner Diameter 0.19 in | In distribution | |
| 5558301569 | 30 | In distribution | |
| 8888270702 | Outer Diameter 11 mm | 100 | In distribution |
| 155650 | 100 | In distribution | |
| 8888301739 | Outer Diameter 0.28 in | In distribution | |
| 8888230201 | 100 | In distribution | |
| 891879 | 1,000 | In distribution | |
| 5558301536 | 30 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Cardinal Health | Cardinal Health 200, LLC | 78 |
| Argyle | Cardinal Health | 71 |
| Buffalo Filter | Buffalo Filter Co., Inc. | 46 |
| Medline | Medline Industries, Inc. | 27 |
| Conmed Buffalo Filter | ConMed Corporation | 20 |
| Alleset | GRI Medical & Electronic Technology Co., Ltd. | 20 |
| Tubing, Noninvasive | ConMed Corporation | 19 |
| Custom Medical Specialties, Inc. | Custom Assemblies, Inc. | 19 |
| Silicone Tubing | Invotec International, Inc. | 19 |
| Welmed | Welmed, Inc. | 18 |
| Axiom® | Axiom Medical, Inc. | 16 |
| Bemis | Bemis Manufacturing Co. | 14 |
Showing 12 of 124. All products under Tubing, Noninvasive
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Closed |
|---|---|---|---|---|
| 2010-08-16 | Not classified | Other | The packaging seals may not be intact, resulting in compromised sterility for the listed Medi-Vac Non-Conductive Tubing. | 2011-11-28 |
| 2010-08-16 | Not classified | Other | The packaging seals may not be intact, resulting in compromised sterility for the listed Medi-Vac Non-Conductive Tubing. | 2011-11-28 |
| 2010-08-16 | Not classified | Other | The packaging seals may not be intact, resulting in compromised sterility for the listed Medi-Vac Non-Conductive Tubing. | 2011-11-28 |
| 2010-08-16 | Not classified | Other | The packaging seals may not be intact, resulting in compromised sterility for the listed Medi-Vac Non-Conductive Tubing. | 2011-11-28 |
| 2010-08-16 | Not classified | Other | The packaging seals may not be intact, resulting in compromised sterility for the listed Medi-Vac Non-Conductive Tubing. | 2011-11-28 |
| 2010-08-16 | Not classified | Other | The packaging seals may not be intact, resulting in compromised sterility for the listed Medi-Vac Non-Conductive Tubing. | 2011-11-28 |
| 2010-08-16 | Not classified | Other | The packaging seals may not be intact, resulting in compromised sterility for the listed Medi-Vac Non-Conductive Tubing. | 2011-11-28 |
| 2010-08-16 | Not classified | Other | The packaging seals may not be intact, resulting in compromised sterility for the listed Medi-Vac Non-Conductive Tubing. | 2011-11-28 |
| 2010-08-16 | Not classified | Other | The packaging seals may not be intact, resulting in compromised sterility for the listed Medi-Vac Non-Conductive Tubing. | 2011-11-28 |
| 2010-08-16 | Not classified | Other | The packaging seals may not be intact, resulting in compromised sterility for the listed Medi-Vac Non-Conductive Tubing. | 2011-11-28 |