Getinge 86-SERIES

WASHER DISINFECTOR Catalog number was S-86661001. Catalog number updated to S-86662001 in November 2018.

Registry build 21.09.26
9manufacturers in China registered for this device type
6catalogue numbers in this listing
8recalls on this code

Who Else Makes It

Concentrated in Guangdong (6), Jiangsu (1), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MEC
Manufacturer City Province Registered as Device types
Shenzhen Denco Medical Co., Ltd. Shenzhen Guangdong Contract manufacturer 52
Medease Life Co., Ltd. Danyang Jiangsu Contract manufacturer 15
Shenzhen Rogin Medical Co., Ltd. Shenzhen Guangdong Contract manufacturer 51
Dongguan Yingfeng Metal & Plastic Products Co., Ltd. Dongguan Guangdong Contract manufacturer 14
Aopu Lighting (Jinyun) Co., Ltd. Lishui Zhejiang Contract manufacturer 9
Dongguan I-Believe Electronic Appliance Co., Ltd. Dongguan Guangdong Manufacturer 5
Guangdong Eraclean Technology Co., Ltd. Zhongshan Guangdong Manufacturer 3
Xiamen Forsound Hearing Technology Co., Ltd. Xiamen Fujian Contract manufacturer 3
Zhongshan Sunclean Co., Ltd. Zhongshan Guangdong Manufacturer 3

Record

Regulatory record for Getinge 86-SERIES
Listed by Getinge Disinfection AB, Sweden
FDA product code MEC
Device type Disinfector, Medical Devices
Device class Class 2
Regulation 21 CFR 880.6992
Establishment Manufacturer
Premarket notification Exempt
Record published 2016-09-22
Record revised 2025-10-23 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Getinge 86-SERIES
Catalogue number Size Status
S-8666 In distribution
S-8668T In distribution
S-8666 In distribution
S-8668 In distribution
S-8668 In distribution
S-8668T In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Steelco Steelco SPA 106
Disinfector, Medical Devices Corporation Steris Canada 76
Amsco Corporation Steris Canada 69
Accessory Getinge Disinfection AB 64
Sterling P1800 Skytron, LLC 43
CleanStart Skytron, LLC 31
I-Series Washers Skytron, LLC 26
Sterling C2000 Skytron, LLC 25
Vision Corporation Steris Canada 25
Reliance Vision Corporation Steris Canada 24
Sterling Washers Skytron, LLC 23
Disinfector, Medical Devices Medisafe UK Ltd. 16

Showing 12 of 96. All products under Disinfector, Medical Devices

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of Getinge 86-SERIES
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Getinge Disinfection AB UDI-DI 2018-03-02 Class II Software design There is potential for a cart with disinfected goods to unload without the trolley being docked. Disinfected goods could end up falling to the floor causing risk to nearby users and damage to goods and equipment. 170 total products 2022-05-13

Recalls

6 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-08-29 Class II Under Investigation by firm Potential for device to overheat during operation if the circulation pressure calibration was not performed or had been performed incorrectly, and the low-pressure alarm is not triggered. 902 units
2025-04-02 Class II Under Investigation by firm The frequency inverter is not programmed by supplier according to specification which causes the circulation pump to start earlier than expected, resulting in additional wear and tear, earlier than expected, on the axial seal in the pump ho 424 units (79 US, 345 OUS)
2025-04-02 Class II Under Investigation by firm The frequency inverter is not programmed by supplier according to specification which causes the circulation pump to start earlier than expected, resulting in additional wear and tear, earlier than expected, on the axial seal in the pump ho 102 units (8 US, 94 OUS)
2018-03-02 Class II Software design There is potential for a cart with disinfected goods to unload without the trolley being docked. Disinfected goods could end up falling to the floor causing risk to nearby users and damage to goods and equipment. 170 total products 2022-05-13
2015-06-26 Class III Software Manufacturing/Software Deployment Getinge Disinfection AB has initiated a Field Correction due to the potential for unauthenticated remote access to the product over the network. 20 devices 2018-05-23
2014-11-26 Class II Device Design Getinge Disinfection AB received complaints regarding sediment residuals in the manifold of the washer and disinfector of Getinge 46-Series (CM302) with PACS 300/350 control. After performing detailed root cause analysis, the firm has iden 551 total: USA: 547 units, Canada: 4 units 2017-05-12
2013-07-30 Class II Nonconforming Material/Component Getinge Disinfection AB initiated a voluntary field safety correction for the Getinge 46-Series electrically-heated Washer Disinfectors due to possible overheating. 143 units (142 domestically & 1 unit internationally) 2015-05-11

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer