Sterilant, Medical Devices

The Quick Connects for Pentax X/00/01/P Series Gastroscopes without Water Jets are and VSB-2900 used with C1160E Universal Flexible Processing Trays in the System 1E Liquid Chemical…

Registry build 21.09.26

The Quick Connects for Pentax X/00/01/P Series Gastroscopes without Water Jets are and VSB-2900 used with C1160E Universal Flexible Processing Trays in the System 1E Liquid Chemical Processing System.

1manufacturer
29catalogue numbers in this listing

Who Else Makes It

Registered in Zhejiang. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code MED
Manufacturer City Province Registered as Device types
Saint-Gobain Life Sciences (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 5

Record

Regulatory record for Sterilant, Medical Devices
Listed by Corporation Steris Canada
FDA product code MED
Device type Sterilant, Medical Devices
Device class Class 2
Regulation 21 CFR 880.6885
510(k) K090036
Record published 2016-09-13
Record revised 2021-06-22 (version 11)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Over the counter Yes
Label carries lot or batch number, serial number
Distribution end date 2022-10-19

Catalogue Numbers

Catalogue numbers for Sterilant, Medical Devices
Catalogue number Size Status
C1200E In distribution
C1222E In distribution
C1201E In distribution
C1202E In distribution
C1142E In distribution
C3000XL In distribution
C1221E In distribution
C1220E In distribution
C1141E In distribution
C1140E In distribution
C1160E In distribution
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn
Quick Connect Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Sterilant, Medical Devices Steris Corporation 149
Formed Irrigating Cystotomes Sterimedix Ltd. 37
Hydrodissection Cannulae Sterimedix Ltd. 29
Anterior Chamber Maintenance Cannulae Sterimedix Ltd. 17
Anaesthetic Needles Sterimedix Ltd. 14
Formed Capsularhexis Cystotomes Sterimedix Ltd. 8
Refractive Cannulae Sterimedix Ltd. 8
enspire Corporation Steris Canada 8
Cidex™ Advanced Sterilization Products Services Inc. 8
Bimanual Cannulae and Hand Pieces Sterimedix Ltd. 7
Bimanual I/A Systems Sterimedix Ltd. 7
McKesson Mckesson Medical-Surgical Inc. 7

Showing 12 of 96. All products under Sterilant, Medical Devices

Recalls Naming This Product

6 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Sterilant, Medical Devices
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Steris Corporation 510(k) number 2015-12-04 Class II Nonconforming Material/Component The firm discovered that one of the hysteroscope models listed for processing in four existing Quick Connects has one inlet port rather than two inlet ports as indicated in the Quick Connect processing instructions. 809 units 2016-08-26
Steris Corporation 510(k) number 2013-03-04 Class II Labeling Change Control During a routine label review, the firm identified four SYSTEM 1E Quick Connects that will be updated to reflect the removal of obsolete device models. This labeling review process also highlighted the opportunity to combine two existing q QLC1677E: 38; QRC1699E: 128 & QPC1721E/QFC1683E: 0 2013-07-02
Steris Corporation 510(k) number 2012-08-10 Class II Device Design STERIS has been actively seeking devices for quick connect revalidation projects. STERIS was unable to obtain two (2) of the needed devices; these two devices represent the design of seven (7) models in one quick connect. Due to the unava 64 units 2013-07-05
Steris Corporation 510(k) number 2012-08-01 Class II Nonconforming Material/Component The firm initiated a recall after complaint investigations revealed that when the units are left on and not in use at night and/or on weekends the hose disconnects/separates resulting in water leakage that can cause damage to property. 6,051 units 2014-06-06
Steris Corporation 510(k) number 2011-12-07 Not classified Software design Software deficiency. STERIS identified that water specifications were not being met at some of their customer sites. Critical parameters for initiating cycles are: water quality, water pressure and water temperature. Failure to meet thes 3,882 units were distributed 2014-05-13
Steris Corporation 510(k) number 2011-03-14 Not classified Other The printout, display and Operator Manual for the STERIS System 1E Liquid Chemical Sterilant Processing System are subject to recall/correction by the firm because in the event of an incomplete or aborted cycle, the language of the warnin 106 units 2013-03-13

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer