Trilogy 200
Trilogy 200 Ventilator with Bluetooth, Italy
11manufacturers in China registered for this device type
2catalogue numbers in this listing
Who Else Makes It
Concentrated in Guangdong (4), Shanghai (3), Jiangsu (2). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Primecare Medical (Suzhou) Co., Ltd. | Changshu | Jiangsu | Contract manufacturer | 20 |
| Shenzhen Insighters Medical Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| Changshu Rozer Sterilization Technology Co., Ltd. | Changshu | Jiangsu | Contract manufacturer | 43 |
| Hangzhou Primecare Medical Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Shanghai Mediworks Precision Instruments Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 13 |
| Zhejiang Yigao Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 7 |
| Resvent Medical Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 6 |
| Shanghai Draeger Medical Instrument Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 4 |
Record
| Listed by | Respironics Inc., United States |
|---|---|
| FDA product code | OUG |
| Device type | Medical Device Data System |
| Device class | Class 1 |
| Regulation | 21 CFR 880.6310 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K093416 |
| Record published | 2016-09-23 |
| Record revised | 2021-03-01 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
| Storage | Storage environment humidity 15 to 95 % RH; Storage environment temperature -4 to 140 °F |
| Distribution end date | 2021-02-28 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Trilogy 200 Ventilator, Italy, Bluetooth | In distribution | |
| Trilogy 200 Ventilator, Japan-Recert | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Responder | Rauland-Borg Corporation | 170 |
| Medical Device Data System | Pentax of America, Inc. | 72 |
| DreamStation | Respironics Inc. | 55 |
| Endopro IQ | Pentax of America, Inc. | 49 |
| MonitAir | Monitair, LLC | 22 |
| Medical Device Data System | Medtronic, Inc. | 20 |
| DreamMapper | Respironics Inc. | 16 |
| Arthrex® | Arthrex, Inc. | 14 |
| Visionflex | Visionflex PTY Limited | 11 |
| Intesys Clinical Suite | Spacelabs Healthcare (Washington), Inc | 11 |
| myoncare | Oncare GmbH | 9 |
| MicroScan | Beckman Coulter, Inc. | 9 |
Showing 12 of 281. All products under Medical Device Data System
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Respironics Inc. | 510(k) number | 2022-12-07 | Class I | Process design | The replacement silicone sound abatement foam installed into some Trilogy 100 and Trilogy 200 devices may separate from the plastic backing to which it is attached. If this were to happen, the foam could potentially block air inlet, which c | 537 devices | |
| Respironics Inc. | 510(k) number | 2021-06-14 | Class I | Device Design | The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the devices air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals. | 255810 | |
| Philips Respironics, Inc. | 510(k) number | 2016-01-18 | Class II | Software design | Software Issue | 104,508 units | 2017-05-26 |
| Respironics Inc. | 510(k) number | 2014-02-11 | Class I | Component design/selection | Internal testing revealed a potentially defective component on the power management board that could affect the function of certain Trilogy Ventilators resulting in loss of therapy to patients. | 572 | 2015-04-17 |
| Respironics Inc. | 510(k) number | 2012-04-27 | Class I | Component design/selection | The specified Trilogy units are being recalled because of the potential for a faulty component in the power supply. | 173 | 2012-11-01 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.