Continuous Measurement Thermometer

2 catalogue numbers from N-CAiO-00, listed by GE Healthcare Finland OY, Finland, under Continuous Measurement Thermometer. 115 manufacturers in China are registered for this product code.

Registry build 21.09.26
115manufacturers in China registered for this device type
2catalogue numbers in this listing

Who Else Makes It

Concentrated in Guangdong (68), Zhejiang (15), Jiangsu (13). 17 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FLL
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Well Lead Medical Co., Ltd. Guangzhou Guangdong Contract manufacturer 46
Zhejiang Hongyu Medical Commodity Co., Ltd. Yiwu Zhejiang Contract manufacturer 36
Hochuen Medical Technology Co., Ltd. Shenzhen Guangdong Contract manufacturer 20
Jiangyin Sinbon Electronics Co Ltd Jiangyin Jiangsu Contract manufacturer 13
Tianjin Choice Medical Device Co., Ltd. Tianjin Tianjin Contract manufacturer 12
Medwell Technology Limited Dongguan Guangdong Contract manufacturer 10
Famidoc Technology Co., Ltd. Dong Guan Guangdong Contract manufacturer 9
EMI (Dongguan) Asia Limited Dongguan Guangdong Contract manufacturer 9
Tasco Medical Industries Co., Ltd. Bao An District, Shenzhen Guangdong Contract manufacturer 6
Wuhan Strong Electronics Wuhan Hubei Contract manufacturer 6
Betacera Inc. Suzhou Jiangsu Contract manufacturer 3

Showing 12 of 115. All 115 manufacturers in China registered for Continuous Measurement Thermometer

Record

Regulatory record for Continuous Measurement Thermometer
Listed by GE Healthcare Finland OY, Finland
FDA product code FLL
Device type Continuous Measurement Thermometer
Device class Class 2
Regulation 21 CFR 880.2910
Establishment Specification developer, Repacker / relabeller, Manufacturer
510(k) K133576
Record published 2016-06-03
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Handling environment humidity 10 to 98 % RH; Handling environment atmospheric pressure 66 to 106 KiloPascal; Storage environment atmospheric pressure 50 to 106 KiloPascal; Handling environment temperature 10 to 40 °C; Storage environment temperature -25 to 60 °C; Storage environment humidity 10 to 90 % RH

Catalogue Numbers

Catalogue numbers for Continuous Measurement Thermometer
Catalogue number Size Status
N-CAiO-00 In distribution
USB Remote Control In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Unimed Unimed Medical Supplies Inc 434
Safety 1st Dorel Juvenile Group, Inc. 180
Welch Allyn, Inc. Welch Allyn, Inc. 66
Diagnostix™ American Diagnostic Corp. 61
DeRoyal Deroyal Industries, Inc. 58
Braun KAZ USA, Inc. 53
Exergen Temporal Scanner Exergen Corporation 50
Level 1 ICU Medical, Inc 48
Famidoc Famidoc Technology Co., Ltd. 47
Adtemp™ American Diagnostic Corp. 35
TempTraq Blue Spark Technologies, Inc. 35
Medline Medline Industries, Inc. 34

Showing 12 of 843. All products under Continuous Measurement Thermometer

Recalls Naming This Product

6 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Continuous Measurement Thermometer
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
GE Medical Systems, LLC 510(k) number 2019-09-27 Class I Process control Displayed End Tidal Oxygen (EtO2) and Fraction of Inspired Oxygen (FiO2) values may be incorrect which could cause up to 50% measurement error in the EtO2/FiO2 values. 12 units 2023-09-26
GE Medical Systems, LLC 510(k) number 2018-09-11 Class II Software design Patient monitors may restart due to network overload caused by network configuration. 33,065 patient monitors
GE Medical Systems, LLC 510(k) number 2015-05-04 Class II Software design The heart rate could be calculated from pacer pulses without indication that pacemaker detection is OFF in some combinations of Bx50 monitors, a PDM, and CIC/CSCS. Then the monitor does not show the Pacer Off message and there may not be an 110 (83 units US, 27 units OUS) 2015-09-15
GE Medical Systems, LLC 510(k) number 2014-08-08 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue due to a failure of an O2 sensor component associated with the CARESCAPE respiratory modules, the Airway Gas Option and their respective service exchange units. 748 (307 units US, 441 units OUS) 2015-09-08
GE Medical Systems, LLC 510(k) number 2014-06-13 Class II Software design Partial loss of monitoring with the CARESCAPE Monitor B850, B650 or B450. When connecting the PDM (Patient Data Module) to the CARESCAPE B850, B650 or B450 monitor with software version 2 the PDM may not start communicating to the monitor 41,992 (20,509 US; 21,483 OUS) 2016-09-07
GE Medical Systems, LLC 510(k) number 2014-02-28 Class II Software design GE Healthcare has recently become aware of potential safety issues associated with the CARESCAPE Monitor B850 and CARESCAPE Monitor B650. These issues include both NIBP (Non-Invasive Blood Pressure) and Bed to Bed Issues. 676 units OUS 2015-04-29

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer