Direct Supply
The AVSM2 is intended to be used to monitor noninvasive blood pressure (NIBP) - systolic, diastolic and mean arterial pressures, functional arterial oxygen saturation (SpO2), pulse rate…
The AVSM2 is intended to be used to monitor noninvasive blood pressure (NIBP) – systolic, diastolic and mean arterial pressures, functional arterial oxygen saturation (SpO2), pulse rate (PR), temperature (Temp) for adult, pediatric and neonatal patients in all areas of a hospital and hospital-type facilities. Monitor users should be skilled at the level of a technician, doctor, nurse or medical specialist. The AVSM2 is suitable for continuous operation.
Who Else Makes It
Concentrated in Guangdong (68), Zhejiang (15), Jiangsu (13). 17 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Well Lead Medical Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 46 |
| Zhejiang Hongyu Medical Commodity Co., Ltd. | Yiwu | Zhejiang | Contract manufacturer | 36 |
| Hochuen Medical Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 20 |
| Jiangyin Sinbon Electronics Co Ltd | Jiangyin | Jiangsu | Contract manufacturer | 13 |
| Tianjin Choice Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 12 |
| Medwell Technology Limited | Dongguan | Guangdong | Contract manufacturer | 10 |
| Famidoc Technology Co., Ltd. | Dong Guan | Guangdong | Contract manufacturer | 9 |
| EMI (Dongguan) Asia Limited | Dongguan | Guangdong | Contract manufacturer | 9 |
| Tasco Medical Industries Co., Ltd. | Bao An District, Shenzhen | Guangdong | Contract manufacturer | 6 |
| Wuhan Strong Electronics | Wuhan | Hubei | Contract manufacturer | 6 |
| Betacera Inc. | Suzhou | Jiangsu | Contract manufacturer | 3 |
Showing 12 of 115. All 115 manufacturers in China registered for Continuous Measurement Thermometer
Record
| Listed by | Mediana Co., Ltd., South Korea |
|---|---|
| FDA product code | FLL |
| Device type | Continuous Measurement Thermometer |
| Device class | Class 2 |
| Regulation | 21 CFR 880.2910 |
| Establishment | Contract manufacturer, Manufacturer |
| 510(k) | K152659 |
| Record published | 2018-10-26 |
| Record revised | 2021-11-10 (version 6) |
Specifications
| MRI safety | MR Safe |
|---|---|
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | manufacturing date, serial number |
| Distribution end date | 2016-10-27 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| AVSM2 | In distribution | |
| AVSM2 | In distribution | |
| AVSM2 | In distribution | |
| AVSM2 | In distribution | |
| AVSM2 | In distribution | |
| AVSM2 | In distribution | |
| AVSM2 | Withdrawn | |
| AVSM2 | Withdrawn | |
| AVSM2 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Unimed | Unimed Medical Supplies Inc | 434 |
| Safety 1st | Dorel Juvenile Group, Inc. | 180 |
| Welch Allyn, Inc. | Welch Allyn, Inc. | 66 |
| Diagnostix™ | American Diagnostic Corp. | 61 |
| DeRoyal | Deroyal Industries, Inc. | 58 |
| Braun | KAZ USA, Inc. | 53 |
| Exergen Temporal Scanner | Exergen Corporation | 50 |
| Level 1 | ICU Medical, Inc | 48 |
| Famidoc | Famidoc Technology Co., Ltd. | 47 |
| Adtemp™ | American Diagnostic Corp. | 35 |
| TempTraq | Blue Spark Technologies, Inc. | 35 |
| Medline | Medline Industries, Inc. | 34 |
Showing 12 of 843. All products under Continuous Measurement Thermometer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K160358 | 2017-02-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.