No-Touch Forehead Thermometer
No-touch forehead thermometer with fast 1 second measurement and high temperature notification. 25 memory reading.
Who Else Makes It
Concentrated in Guangdong (68), Zhejiang (15), Jiangsu (13). 17 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Well Lead Medical Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 46 |
| Zhejiang Hongyu Medical Commodity Co., Ltd. | Yiwu | Zhejiang | Contract manufacturer | 36 |
| Hochuen Medical Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 20 |
| Jiangyin Sinbon Electronics Co Ltd | Jiangyin | Jiangsu | Contract manufacturer | 13 |
| Tianjin Choice Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 12 |
| Medwell Technology Limited | Dongguan | Guangdong | Contract manufacturer | 10 |
| Famidoc Technology Co., Ltd. | Dong Guan | Guangdong | Contract manufacturer | 9 |
| EMI (Dongguan) Asia Limited | Dongguan | Guangdong | Contract manufacturer | 9 |
| Tasco Medical Industries Co., Ltd. | Bao An District, Shenzhen | Guangdong | Contract manufacturer | 6 |
| Wuhan Strong Electronics | Wuhan | Hubei | Contract manufacturer | 6 |
| Betacera Inc. | Suzhou | Jiangsu | Contract manufacturer | 3 |
Showing 12 of 115. All 115 manufacturers in China registered for Continuous Measurement Thermometer
Record
| Listed by | Omron Healthcare, Inc., United States |
|---|---|
| FDA product code | FLL |
| Device type | Continuous Measurement Thermometer |
| Device class | Class 2 |
| Regulation | 21 CFR 880.2910 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K121428 |
| Record published | 2021-09-01 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Over the counter | Yes |
| Label carries | lot or batch number |
| Storage | Handling environment temperature 10 to 40 °C; Handling environment temperature 50 to 104 °F; Handling environment atmospheric pressure 70 to 106 KiloPascal; Handling environment humidity 15 to 85 % RH; Storage environment temperature -20 to 60 °C; Storage environment temperature -4 to 140 °F |
| Packaging | Case of 10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| ET720 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Unimed | Unimed Medical Supplies Inc | 434 |
| Safety 1st | Dorel Juvenile Group, Inc. | 180 |
| Welch Allyn, Inc. | Welch Allyn, Inc. | 66 |
| Diagnostix™ | American Diagnostic Corp. | 61 |
| DeRoyal | Deroyal Industries, Inc. | 58 |
| Braun | KAZ USA, Inc. | 53 |
| Exergen Temporal Scanner | Exergen Corporation | 50 |
| Level 1 | ICU Medical, Inc | 48 |
| Famidoc | Famidoc Technology Co., Ltd. | 47 |
| Adtemp™ | American Diagnostic Corp. | 35 |
| TempTraq | Blue Spark Technologies, Inc. | 35 |
| Medline | Medline Industries, Inc. | 34 |
Showing 12 of 843. All products under Continuous Measurement Thermometer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K091676 | 2009-09-01 |
| K051233 | 2005-06-21 |
| K922344 | 1993-06-29 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2005-10-25 | Not classified | Other | Omron is recalling the Omron 3-Way Instant Thermometers due to possible overheating of the probe tip. | Approximately 48,000 units | 2007-11-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.