Dart
The DART Daily Air Removal Test is a pre-assembled Bowie-Dick test pack product used in monitoring healthcare steam sterilizers.
Who Else Makes It
Concentrated in Guangdong (7), Anhui (4), Hubei (3). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Hubei Qianjiang Kingphar Medical Material Co., Ltd. | Qianjiang | Hubei | Contract manufacturer | 52 |
| Shanghai Jianzhong Medical Packaging Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 3 |
| Dongguan Safesecure Medical Packaging Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 2 |
| Jiangsu Jsongmed Medical Material Co., Ltd. | Jiangsu | Jiangsu | Contract manufacturer | 2 |
| Hubei Guarddent Medical Technology Co., Ltd. | Wuhan | Hubei | Manufacturer | 60 |
| Shanghai Hua En Industrial Co Ltd | Shanghai | Shanghai | Contract manufacturer | 52 |
| Anqing Clean Dental Instrument Technology Co., Ltd. | Anqing | Anhui | Manufacturer | 50 |
| Lakong Medical Devices Co., Ltd. | Dongguan | Guangdong | Remanufacturer | 39 |
| Wellmed Dental Medical Supply Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 37 |
| Premium Plus (Dongguan) Limited | Dongguan | Guangdong | Repacker / relabeller | 34 |
| Anhui Ares Medical Technology Co., Ltd. | Tianchang | Anhui | Contract manufacturer | 28 |
| Bgss Company Asia Limited | Zhabei | Shanghai | Contract manufacturer | 25 |
Showing 12 of 19. All 19 manufacturers in China registered for Indicator, Physical/Chemical Sterilization Process
Record
| Listed by | Steris Corporation, United States |
|---|---|
| FDA product code | JOJ |
| Device type | Indicator, Physical/Chemical Sterilization Process |
| Device class | Class 2 |
| Regulation | 21 CFR 880.2800 |
| Establishment | Contract manufacturer, Contract steriliser, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2016-09-09 |
| Record revised | 2026-02-09 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Over the counter | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Keep away from direct light; Storage environment temperature 36 to 75 °F; Storage environment humidity 30 to 80 % RH |
| Packaging | Case of 5 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| NB215 | 10 | In distribution | |
| NB113 | 10 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Hu-Friedy | HU-Friedy MFG Co., LLC | 32 |
| JMU | JMU Dental, Inc | 32 |
| MARK3 | Cargus International, Inc | 28 |
| Comply™ | 3M Company | 25 |
| Verify | Albert Browne Ltd. | 24 |
| Cardinal Health | Cardinal Health 200, LLC | 19 |
| Verify | Steris Corporation | 18 |
| McKesson | Mckesson Medical-Surgical Inc. | 16 |
| Sklar® | Sklar Corporation | 14 |
| Case Medical | Case Medical, Inc. | 13 |
| Dental City | ICP, Inc. | 13 |
| PlastCare | Proguard Health Inc. | 12 |
Showing 12 of 278. All products under Indicator, Physical/Chemical Sterilization Process
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K251048 | 2025-05-02 |
| K243876 | 2025-04-25 |
| K243475 | 2024-12-04 |
| K242189 | 2024-08-20 |
| K241344 | 2024-06-11 |
| K240032 | 2024-04-17 |
| K240760 | 2024-04-10 |
| K233654 | 2023-12-08 |
| K233187 | 2023-10-27 |
| K231488 | 2023-08-07 |
| K230558 | 2023-07-17 |
| K192020 | 2019-09-05 |
| K183293 | 2019-01-04 |
| K182724 | 2018-12-10 |
| K173428 | 2018-03-02 |
| K172746 | 2018-02-09 |
| K172753 | 2018-02-09 |
| K172472 | 2017-11-17 |
| K162758 | 2017-03-21 |
| K162631 | 2017-01-27 |
| K160485 | 2016-06-01 |
| K152630 | 2016-05-12 |
| K143333 | 2015-04-14 |
| K140515 | 2014-07-17 |
| K130160 | 2013-08-16 |
| K120435 | 2012-06-04 |
| K112256 | 2012-01-11 |
| K103331 | 2011-09-01 |
| K103053 | 2011-03-10 |
| K102296 | 2011-02-09 |
| K102217 | 2010-11-22 |
| K091174 | 2009-10-27 |
| K083643 | 2009-08-07 |
| K081600 | 2008-08-22 |
| K081427 | 2008-06-11 |
| K080750 | 2008-05-12 |
| K073683 | 2008-01-25 |
| K072510 | 2007-12-11 |
| K071895 | 2007-11-14 |
| K070895 | 2007-09-05 |
| K070461 | 2007-07-17 |
| K043482 | 2004-12-21 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-08-10 | Class III | Process control | Product contains incorrect chemical indicators in packaging. | 619 boxes | 2024-10-30 |
| 2013-12-19 | Class II | Labeling False and Misleading | STERIS has identified that the outer shipping package for one lot (Lot #024552A) of VERIFY SixCess Challenge Packs incorrectly identifies the lot as Lot #024522A. | 94 boxes/20 units | 2014-03-26 |
| 2011-03-16 | Not classified | Labeling False and Misleading | During an inspection the firm was notified that language contained in labeling and promotional literature directs Customers that the products can be used to replace biological indicators and/or release loads containing implants. | 2,500 | 2013-03-19 |
| 2011-03-16 | Not classified | Labeling False and Misleading | During an inspection the firm was notified that language contained in labeling and promotional literature directs Customers that the products can be used to replace biological indicators and/or release loads containing implants. | 2,500 (one per customer) | 2013-03-19 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.