Wavicide®

3150 Wavicide MEC Indicators

Registry build 21.09.26
19manufacturers in China registered for this device type
1catalogue number
24510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Concentrated in Guangdong (7), Anhui (4), Hubei (3). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JOJ
Manufacturer City Province Registered as Device types
Hubei Qianjiang Kingphar Medical Material Co., Ltd. Qianjiang Hubei Contract manufacturer 52
Shanghai Jianzhong Medical Packaging Co., Ltd. Shanghai Shanghai Contract manufacturer 3
Dongguan Safesecure Medical Packaging Co., Ltd. Dongguan Guangdong Contract manufacturer 2
Jiangsu Jsongmed Medical Material Co., Ltd. Jiangsu Jiangsu Contract manufacturer 2
Hubei Guarddent Medical Technology Co., Ltd. Wuhan Hubei Manufacturer 60
Shanghai Hua En Industrial Co Ltd Shanghai Shanghai Contract manufacturer 52
Anqing Clean Dental Instrument Technology Co., Ltd. Anqing Anhui Manufacturer 50
Lakong Medical Devices Co., Ltd. Dongguan Guangdong Remanufacturer 39
Wellmed Dental Medical Supply Co., Ltd. Shenzhen Guangdong Manufacturer 37
Premium Plus (Dongguan) Limited Dongguan Guangdong Repacker / relabeller 34
Anhui Ares Medical Technology Co., Ltd. Tianchang Anhui Contract manufacturer 28
Bgss Company Asia Limited Zhabei Shanghai Contract manufacturer 25

Showing 12 of 19. All 19 manufacturers in China registered for Indicator, Physical/Chemical Sterilization Process

Record

Regulatory record for Wavicide®
Listed by 3M Company, United States
FDA product code JOJ
Device type Indicator, Physical/Chemical Sterilization Process
Device class Class 2
Regulation 21 CFR 880.2800
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
Record published 2016-09-24
Record revised 2025-02-21 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Label carries lot or batch number, expiry date
Packaging Box of 6

Catalogue Numbers

Catalogue numbers for Wavicide®
Catalogue number Size Per pack Status
3150 50 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Hu-Friedy HU-Friedy MFG Co., LLC 32
JMU JMU Dental, Inc 32
MARK3 Cargus International, Inc 28
Comply™ 3M Company 25
Verify Albert Browne Ltd. 24
Cardinal Health Cardinal Health 200, LLC 19
Verify Steris Corporation 18
McKesson Mckesson Medical-Surgical Inc. 16
Sklar® Sklar Corporation 14
Case Medical Case Medical, Inc. 13
Dental City ICP, Inc. 13
PlastCare Proguard Health Inc. 12

Showing 12 of 278. All products under Indicator, Physical/Chemical Sterilization Process

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K222508 2022-11-01
K222152 2022-09-23
K220942 2022-06-24
K220564 2022-05-23
K212081 2021-09-05
K203458 2020-12-11
K203285 2020-12-10
K193254 2019-12-23
K191236 2019-11-22
K192937 2019-11-16
K192673 2019-10-28
K183211 2019-02-26
K183209 2019-02-15
K170321 2017-08-14
K170563 2017-07-27
K150694 2015-10-01
K150622 2015-09-29
K150477 2015-07-02
K101528 2010-10-01
K101249 2010-09-08
K093199 2009-12-04
K020589 2002-04-22
K932129 1994-03-04
K801057 1980-06-17

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2023-04-06 Class II Process control 3M Attest Steam Chemical Integrators with dates of manufacture between November 6, 2022 and January 17, 2023 have an increased potential to leak ink during a sterilization cycle. 16,229,000 units
2023-04-06 Class II Process control 3M Attest Steam Chemical Integrators with dates of manufacture between November 6, 2022 and January 17, 2023 have an increased potential to leak ink during a sterilization cycle. 2,235,000 units
2008-03-19 Not classified Nonconforming Material/Component A production specification discrepancy may cause the indicators to show an inaccurate result, which could incorrectly lead customers to conclude the sterilization cycle was adequate. 12,998 cases ( 4 boxes per case & 480 strips per box)) 2012-03-01
2006-08-09 Not classified Other 3M Comply 1248 Gas Plasma Chemical Indicator Strips were manufactured with a material that may cause some of the indicators to show an inaccurate result if not read immediately after processing. 6248 cases (4 boxes/case) 2007-05-25

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer