BD Intraosseous Vascular Access System

BD Intraosseous Powered Driver (Refurb)

Registry build 21.09.26
71manufacturers in China registered for this device type
13catalogue numbers in this listing
3recalls on this code

Who Else Makes It

Concentrated in Jiangsu (20), Zhejiang (19), Shanghai (12). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FMI
Manufacturer City Province Registered as Device types
Ningbo Risenmed Technology Co., Ltd. Ningbo Zhejiang Contract manufacturer 42
Jiangsu Caina Medical Co., Ltd. Jiangyin Jiangsu Contract manufacturer 20
Chengdu Xinjin Shifeng Medical Apparatus & Instrument Co., Ltd. Chengdu Sichuan Contract manufacturer 10
Wuxi Yushou Medical Appliances Co., Ltd. Wuxi Jiangsu Contract manufacturer 8
Anhui Kangda Medical Products Co., Ltd. Tianchang Anhui Contract manufacturer 7
Shenzhen HYS Medical Co., Ltd. Shenzhen Guangdong Contract manufacturer 6
Aena Medical (Jiangsu) Co., Ltd. Jiangyin Jiangsu Contract manufacturer 4
Zhejiang INI Medical Devices Co., Ltd. Wenzhou Zhejiang Contract manufacturer 4
Hantech (Ningbo) Medical Technology Co., Ltd. Ningbo Zhejiang Contract manufacturer 3
Jiangsu NEW Pentastar Medical Products Co., Ltd. Changzhou Jiangsu Exporter 146
Huzhou Junda Industry Co., Ltd. Anji Zhejiang Contract manufacturer 129
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70

Showing 12 of 71. All 71 manufacturers in China registered for Needle, Hypodermic, Single Lumen

Record

Regulatory record for BD Intraosseous Vascular Access System
Listed by Bard Access Systems, Inc., United States
FDA product code FMI
Device type Needle, Hypodermic, Single Lumen
Device class Class 2
Regulation 21 CFR 880.5570
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
Record published 2021-03-17
Record revised 2025-07-17 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date, serial number
Storage Storage environment atmospheric pressure 50 to 106 KiloPascal; Storage environment temperature -40 to 70 °C; Storage environment humidity 0 to 90 % RH
Packaging Box of 2, case of 6, case
Sizes Needle gauge 15 G; length 15 to 55 mm
Distribution end date 2022-06-22

Catalogue Numbers

Catalogue numbers for BD Intraosseous Vascular Access System
Catalogue number Size Status
D015451NK Length 45 mm In distribution
D001001R In distribution
D015551NK Needle Gauge 15 G In distribution
D001001 In distribution
D001002 In distribution
D015251NK Needle Gauge 15 G In distribution
D015351NK Length 35 mm In distribution
D015151NK Length 15 mm In distribution
D015351MK Needle Gauge 15 G Withdrawn
D015451MK Length 45 mm Withdrawn
D015151MK Needle Gauge 15 G Withdrawn
D015551MK Needle Gauge 15 G Withdrawn
D015251MK Length 25 mm Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Sterile Single-use Syringe with Needle Jiangxi Hongda Medical Equipment Group Ltd. 162
Tkmd Anhui Tiankang Medical Technology Co., Ltd. 150
Reli Myco Medical Supplies, Inc. 149
STERiJECT TM TSK Laboratory, Japan 140
Yeso med Wuxi Yushou Medical Appliances Co., Ltd. 130
Monoject Cardinal Health 124
Monoject Cardinal Health 200, LLC 112
Jelco ICU Medical, Inc 108
micsafe Jiangsu Micsafe Medical Tehcnology Co., Ltd. 105
McKesson Mckesson Medical-Surgical Inc. 93
EasyTouch MHC Medical Products 82
Medegen Medical products Medegen Medical Products 78

Showing 12 of 797. All products under Needle, Hypodermic, Single Lumen

Recalls

2 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-07-30 Class I Component change control After placement of intraosseous (IO) needle sets, used when intravenous access is difficult or impossible to obtain in emergent, urgent, or medically necessary cases, users may experience difficulty/inability to remove obturator, due to it 80,200
2022-06-20 Class I Process change control BD Intraosseous Needle Kits may exhibit: 1) Increased force required to remove the stylet from intraosseous needle during placement may cause removal of the entire needle assembly and loss of intraosseous access; 2) Stylet safety mechanism 40,734
2003-09-23 Not classified Other Sterility of product is compromised by open seals in packaging. 106,500 units 2004-03-18

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer