BD Safety-Lok
SYR Safetylok 10ML LL W/NDL 21X1-1/2 TW
Who Else Makes It
Concentrated in Jiangsu (20), Zhejiang (19), Shanghai (12). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Ningbo Risenmed Technology Co., Ltd. | Ningbo | Zhejiang | Contract manufacturer | 42 |
| Jiangsu Caina Medical Co., Ltd. | Jiangyin | Jiangsu | Contract manufacturer | 20 |
| Chengdu Xinjin Shifeng Medical Apparatus & Instrument Co., Ltd. | Chengdu | Sichuan | Contract manufacturer | 10 |
| Wuxi Yushou Medical Appliances Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 8 |
| Anhui Kangda Medical Products Co., Ltd. | Tianchang | Anhui | Contract manufacturer | 7 |
| Shenzhen HYS Medical Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 6 |
| Aena Medical (Jiangsu) Co., Ltd. | Jiangyin | Jiangsu | Contract manufacturer | 4 |
| Zhejiang INI Medical Devices Co., Ltd. | Wenzhou | Zhejiang | Contract manufacturer | 4 |
| Hantech (Ningbo) Medical Technology Co., Ltd. | Ningbo | Zhejiang | Contract manufacturer | 3 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Huzhou Junda Industry Co., Ltd. | Anji | Zhejiang | Contract manufacturer | 129 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
Showing 12 of 71. All 71 manufacturers in China registered for Needle, Hypodermic, Single Lumen
Record
| Listed by | Becton, Dickinson AND Company, United States |
|---|---|
| FDA product code | FMI |
| Device type | Needle, Hypodermic, Single Lumen |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5570 |
| Establishment | Contract manufacturer, Contract steriliser, Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K944757 |
| Record published | 2016-09-19 |
| Record revised | 2025-08-06 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: Keep away from sunlight; Special storage condition: Keep dry; Special storage condition: Fragile, handle with care |
| Packaging | Case of 8, case of 10, pack or inner pack of 50, case of 5, pack or inner pack of 100 |
| Sizes | Length 0.625 to 1.5 in; needle gauge 22 to 25 G |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 305564 | 50 | In distribution | |
| 305902 | Length 1 in | In distribution | |
| 309593 | 100 | In distribution | |
| 305561 | 50 | In distribution | |
| 309606 | 100 | In distribution | |
| 309594 | 100 | In distribution | |
| 309596 | 100 | In distribution | |
| 305554 | In distribution | ||
| 305901 | Length 0.625 in | In distribution | |
| 305558 | 50 | In distribution | |
| 309595 | 100 | In distribution | |
| 305559 | 50 | In distribution | |
| 305900 | Needle Gauge 22 G | In distribution | |
| 305553 | In distribution | ||
| 309592 | 100 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Sterile Single-use Syringe with Needle | Jiangxi Hongda Medical Equipment Group Ltd. | 162 |
| Tkmd | Anhui Tiankang Medical Technology Co., Ltd. | 150 |
| Reli | Myco Medical Supplies, Inc. | 149 |
| STERiJECT TM | TSK Laboratory, Japan | 140 |
| Yeso med | Wuxi Yushou Medical Appliances Co., Ltd. | 130 |
| Monoject | Cardinal Health | 124 |
| Monoject | Cardinal Health 200, LLC | 112 |
| Jelco | ICU Medical, Inc | 108 |
| micsafe | Jiangsu Micsafe Medical Tehcnology Co., Ltd. | 105 |
| McKesson | Mckesson Medical-Surgical Inc. | 93 |
| EasyTouch | MHC Medical Products | 82 |
| Medegen Medical products | Medegen Medical Products | 78 |
Showing 12 of 797. All products under Needle, Hypodermic, Single Lumen
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K223286 | 2022-12-28 |
| K213478 | 2022-06-28 |
| K213156 | 2021-12-08 |
| K212015 | 2021-11-19 |
| K181730 | 2019-03-01 |
| K182320 | 2018-12-20 |
| K170824 | 2018-08-20 |
| K162516 | 2016-12-09 |
| K161553 | 2016-07-06 |
| K161170 | 2016-05-27 |
| K110703 | 2011-07-27 |
| K100005 | 2010-04-15 |
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Becton, Dickinson & Co. | 510(k) number | 2020-07-28 | Class II | Equipment maintenance | Printed scale markings on the 3mL SafetyGlide syringes, with catalog # 305924, Lot# 8289599, are printed incorrectly. The scale is skewed to different degrees, resulting in missing and/or partially printed scale numbers and scale lines. | 125,200 units | 2021-04-23 |
| Becton, Dickinson & Co. | 510(k) number | 2019-02-01 | Class II | Under Investigation by firm | The syringes have scale markings that were printed incorrectly. The scale is skewed to varying degrees, resulting in missing and/or partially printed scale numbers and scale lines. | 428,800 | 2020-06-11 |
| Centurion Medical Products, LP | 510(k) number | 2017-07-05 | Class II | Material/Component Contamination | Centurion is recalling specific lots of convenience kits, SafetyGlide Needle, 22GA 1-1/2in, manufactured by BD, sold in Centurion Convenience Kits. distributed between May 2016 and June 2017 due to notice received from BD’s recall due to pa | 2018-03-09 | |
| Becton, Dickinson & Co. | 510(k) number | 2017-06-13 | Class II | Process control | Presence of loose polypropylene foreign matter above release specification. | 1,249,200 units | 2020-06-22 |
| Becton, Dickinson & Co. | 510(k) number | 2016-09-16 | Class II | Process control | BD identified that several lots did not receive the specified dose of irradiation necessary to meet the Sterility Assurance Level (SAL) required. | 29,500 units | 2018-03-20 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.