F&P Neopuff
Neopuff™ Infant T-Piece Resuscitator FR
Who Else Makes It
Concentrated in Jiangsu (2), Guangdong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Vincent Medical (Dong Guan) Manufacturing Co., Ltd. | Dong Guan | Guangdong | Contract manufacturer | 29 |
| Amphenol (Changzhou) Connector Systems Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 4 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
Record
| Listed by | Fisher & Paykel Healthcare, Ltd., New Zealand |
|---|---|
| FDA product code | FMT |
| Device type | Warmer, Infant Radiant |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5130 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K971695 |
| Record published | 2016-09-08 |
| Record revised | 2026-03-10 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| RD900AFU | In distribution | |
| RD900AEU | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| DeRoyal | Deroyal Industries, Inc. | 37 |
| Fisher & Paykel Healthcare | Fisher & Paykel Healthcare, Ltd. | 9 |
| AirLife™ | AirLife Finland Oy | 8 |
| Tarry Probes | Tarry Medical Products, Inc. | 5 |
| Argyle | Cardinal Health | 5 |
| Panda | Datex-Ohmeda, Inc. | 4 |
| AccuTemp Probe | Kentec Medical, LLC | 3 |
| Ameritus | Kentec Medical, LLC | 3 |
| AirLife | Carefusion Finland 320 Oy | 3 |
| Sunflower Warmer, Stand AC120V | Atom Medical Corporation | 2 |
| Heating Element 540W-104V | RPI | 2 |
| Sunflower Warmer, Wall Mount AC120V | Atom Medical Corporation | 2 |
Showing 12 of 39. All products under Warmer, Infant Radiant
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2014-11-06 | Class II | Manufacturing material removal | Breakage of the nut that secures the heater head in place, which can cause the heater head to become partially detached and swing towards the bassinet. There is the potential that a heater head could contact a patient situated on the bassin | Nationwide (U.S.): 661 Infant Warmers and 180 Spare Parts, I | 2015-04-27 |
| 2006-10-09 | Not classified | Other | This firm has received Product Complaint Reports concerning bending of the pivot plate. The elevator base of the CosyCot Infant Warmer incorporates a pivot plate which forms part of the mechanism allowing the CosyCot to raise and lower in h | 273 units in US & 9 in Canada | 2012-04-26 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.