| Datex-Ohmeda, Inc. | 510(k) number | 2026-05-08 | Class I | Process control | Blender knob shaft can loosen, which can affect the delivered oxygen concentration. The system can deliver an oxygen concentration that does not match the intended concentration set by the user, potentially resulting in hypoxia or hyperoxia | 550 (367 US; 183 OUS) | |
| Datex-Ohmeda, Inc. | 510(k) number | 2026-05-08 | Class I | Process control | Blender knob shaft can loosen, which can affect the delivered oxygen concentration. The system can deliver an oxygen concentration that does not match the intended concentration set by the user, potentially resulting in hypoxia or hyperoxia | 550 (367 US; 183 OUS) | |
| GE Medical Systems, LLC | 510(k) number | 2026-05-01 | Class II | Component design/selection | GE HealthCare has become aware of a potential issue involving the canopy soffit beneath the control panel end of the device. Under certain conditions, for example, impact during transport, one or more of the fasteners that secure the soffit | 23430 units | |
| GE Medical Systems, LLC | 510(k) number | 2026-05-01 | Class II | Component design/selection | GE HealthCare has become aware of a potential issue involving the canopy soffit beneath the control panel end of the device. Under certain conditions, for example, impact during transport, one or more of the fasteners that secure the soffit | 265 units | |
| Datex-Ohmeda, Inc. | 510(k) number | 2024-09-03 | Class I | Use error | GE HealthCare has become aware that for certain Giraffe OmniBed and Giraffe OmniBed Carestation devices, the screw that secures the doors that cover the warmer heaters may not have been torqued to specification. This may lead to the doors b | | |
| Wipro GE Healthcare Private Ltd. | 510(k) number | 2024-08-09 | Class II | Process control | GE HealthCare has become aware that complete electrical safety testing was not conducted during manufacturing of certain Giraffe and Panda iRes Warmers. There are multiple electrical safety protections included in the product design. Howeve | 1 | |
| Wipro GE Healthcare Private Ltd. | 510(k) number | 2024-08-09 | Class II | Process control | GE HealthCare has become aware that complete electrical safety testing was not conducted during manufacturing of certain Giraffe and Panda iRes Warmers. There are multiple electrical safety protections included in the product design. Howeve | 137 units | |
| Datex-Ohmeda, Inc. | 510(k) number | 2023-06-06 | Class I | Component design/selection | Prior to current established manufacturing practices, higher levels of airborne formaldehyde exposure from newly manufactured incubators could be seen during clinical use that would rapidly decrease over a week. Affected customers were noti | 769 units | |
| Datex-Ohmeda, Inc. | 510(k) number | 2023-06-06 | Class I | Component design/selection | Prior to current established manufacturing practices, higher levels of airborne formaldehyde exposure from newly manufactured incubators could be seen during clinical use that would rapidly decrease over a week. Affected customers were noti | 224 units | |
| Datex-Ohmeda, Inc. | 510(k) number | 2023-05-19 | Class II | Nonconforming Material/Component | GE HealthCare has become aware of the potential that an incorrect type of secondary latch could have been installed on the northeast (NE) and/or northwest (NW) bedside panels for certain Giraffe OmniBed and Giraffe OmniBed Carestation devic | 4,540 units | |
| GE Medical Systems, LLC | 510(k) number | 2019-10-11 | Class I | Device Design | Giraffe Incubator, Giraffe OmniBed, Giraffe Incubator Carestation, and Giraffe OmniBed Carestation Bedside panels and portholes can appear closed without being latched. Potential patient fall. | 7814 units | 2024-08-15 |
| GE Medical Systems, LLC | 510(k) number | 2019-10-11 | Class I | Device Design | Giraffe Incubator, Giraffe OmniBed, Giraffe Incubator Carestation, and Giraffe OmniBed Carestation Bedside panels and portholes can appear closed without being latched. Potential patient fall. | 3467 units | 2024-08-15 |
| GE Medical Systems, LLC | 510(k) number | 2019-07-26 | Class II | Nonconforming Material/Component | Fasteners potentially torqued to a value less than the specified value and can potentially cause the canopy to become detached and fall. | 59 devices (50 US, 9 OUS) | |
| GE Medical Systems, LLC | 510(k) number | 2019-03-15 | Class I | Device Design | The bedside panels and latch areas on the Giraffe Bedded Warmer and Panda iRes Warmer can crack or break if the unit is moved using the bedside panels instead of the front handle or the maneuvering handle. | 9,094 devices | 2024-05-21 |
| GE Medical Systems, LLC | 510(k) number | 2019-03-15 | Class I | Device Design | The bedside panels and latch areas on the Giraffe Bedded Warmer and Panda iRes Warmer can crack or break if the unit is moved using the bedside panels instead of the front handle or the maneuvering handle. | 28,094 units | 2024-05-21 |
| GE Medical Systems, LLC | 510(k) number | 2018-09-25 | Class II | Process design | Potential electric leakage affecting the user. | 1,724 devices total | 2020-07-13 |
| GE Medical Systems, LLC | 510(k) number | 2018-09-25 | Class II | Process design | Potential electric leakage affecting the user. | 1,724 devices total | 2020-07-13 |
| GE Medical Systems, LLC | 510(k) number | 2018-09-25 | Class II | Process design | Potential electric leakage affecting the user. | 1,724 devices total | 2020-07-13 |
| GE Medical Systems, LLC | 510(k) number | 2018-09-25 | Class II | Process design | Potential electric leakage affecting the user. | 1,724 devices total | 2020-07-13 |
| GE Medical Systems, LLC | 510(k) number | 2018-09-25 | Class II | Process design | Potential electric leakage affecting the user. | 1,724 devices total | 2020-07-13 |
| GE Medical Systems, LLC | 510(k) number | 2018-09-25 | Class II | Process design | Potential electric leakage affecting the user. | 1,724 devices total | 2020-07-13 |
| GE Healthcare GmbH | 510(k) number | 2014-04-02 | Class II | Software design | Medical device software may be defective and may cause user-set alarm limits to result in false positive or false negative Oxygen saturation and pulse rate alarm notifications to the caregiver. | 50 units | 2016-05-11 |
| GE Healthcare GmbH | 510(k) number | 2014-04-02 | Class II | Software design | Medical device software may be defective and may cause user-set alarm limits to result in false positive or false negative Oxygen saturation and pulse rate alarm notifications to the caregiver. | 723 units | 2016-05-11 |
| GE Healthcare GmbH | 510(k) number | 2014-04-02 | Class II | Software design | Medical device software may be defective and may cause user-set alarm limits to result in false positive or false negative Oxygen saturation and pulse rate alarm notifications to the caregiver. | 21 units | 2016-05-11 |
| GE Healthcare GmbH | 510(k) number | 2014-04-02 | Class II | Software design | Medical device software may be defective and may cause user-set alarm limits to result in false positive or false negative Oxygen saturation and pulse rate alarm notifications to the caregiver. | 15 units | 2016-05-11 |
| GE Healthcare GmbH | 510(k) number | 2013-12-12 | Class II | Process control | Medical device adjustment knob may be loose and affect the accuracy of blended Air/Oxygen gas mixture to patients. | 1970 units | 2015-06-01 |
| GE Healthcare GmbH | 510(k) number | 2013-12-12 | Class II | Process control | Medical device adjustment knob may be loose and affect the accuracy of blended Air/Oxygen gas mixture to patients. | 9232 units | 2015-06-01 |