Giraffe

Giraffe Shuttle

Registry build 21.09.26
2manufacturers in China registered for this device type
1catalogue number
4510(k) clearances naming this product code
7recalls on this code

Who Else Makes It

All of them in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code FMZ
Manufacturer City Province Registered as Device types
Amphenol (Changzhou) Connector Systems Co., Ltd. Changzhou Jiangsu Contract manufacturer 4
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57

Record

Regulatory record for Giraffe
Listed by Datex-Ohmeda, Inc., United States
FDA product code FMZ
Device type Incubator, Neonatal
Device class Class 2
Regulation 21 CFR 880.5400
Establishment Specification developer, Manufacturer, Exporter
510(k) K101778
Record published 2016-06-24
Record revised 2025-03-25 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Storage environment temperature -25 to 45 °C; Storage environment humidity 5 to 85 % RH

Catalogue Numbers

Catalogue numbers for Giraffe
Catalogue number Size Status
Shuttle In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Tarry Probes Tarry Medical Products, Inc. 7
Midas Rex MR8 Medtronic Powered Surgical Solutions 6
Airlife AirLife Finland Oy 6
AirLife Carefusion Finland 320 Oy 5
Multi-Link™ AirLife Finland Oy 3
Access Medical Probes Tarry Medical Products, Inc. 3
Advanced Neonatal Incubator Advanced Instrumentations, Inc. 2
Babyleo TN500 Drägerwerk AG & Co. KGaA 2
Isolette® 8000 plus Draeger Medical Systems, Inc. 2
Isolette 8000 Infant Incubator Draeger Medical Systems, Inc. 1
Skin Temp Probe, 5mm O.D.(Y) Atom Medical Corporation 1
Oxygen Sensor For Dual Incu i, Incu i, V-2200/2100G(2 pcs/set) Atom Medical Corporation 1

Showing 12 of 41. All products under Incubator, Neonatal

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K260326 2026-07-28
K251663 2025-10-22
K213553 2022-03-02
K072512 2007-10-03

Recalls Naming This Product

13 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Giraffe
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
GE Medical Systems, LLC 510(k) number 2026-05-01 Class II Component design/selection GE HealthCare has become aware of a potential issue involving the canopy soffit beneath the control panel end of the device. Under certain conditions, for example, impact during transport, one or more of the fasteners that secure the soffit 19587 units
GE Medical Systems, LLC 510(k) number 2026-05-01 Class II Component design/selection GE HealthCare has become aware of a potential issue involving the canopy soffit beneath the control panel end of the device. Under certain conditions, for example, impact during transport, one or more of the fasteners that secure the soffit 265 units
Datex-Ohmeda, Inc. 510(k) number 2024-09-03 Class I Use error GE HealthCare has become aware that for certain Giraffe OmniBed and Giraffe OmniBed Carestation devices, the screw that secures the doors that cover the warmer heaters may not have been torqued to specification. This may lead to the doors b
Datex-Ohmeda, Inc. 510(k) number 2023-05-19 Class II Nonconforming Material/Component GE HealthCare has become aware of the potential that an incorrect type of secondary latch could have been installed on the northeast (NE) and/or northwest (NW) bedside panels for certain Giraffe OmniBed and Giraffe OmniBed Carestation devic 3,053 units
GE Medical Systems, LLC 510(k) number 2020-04-28 Class II Device Design Potential for certain Giraffe Incubators and Giraffe OmniBeds to deliver a different environmental oxygen level than what is displayed by the device, if a certain optional component referred to as the Servo Oxygen Module is installed. 5,883 units total 2024-09-23
GE Medical Systems, LLC 510(k) number 2020-04-28 Class II Device Design Potential for certain Giraffe Incubators and Giraffe OmniBeds to deliver a different environmental oxygen level than what is displayed by the device, if a certain optional component referred to as the Servo Oxygen Module is installed. 5,883 units total 2024-09-23
GE Medical Systems, LLC 510(k) number 2020-04-02 Class II Device Design During Giraffe Shuttle charging, the batteries emit low concentrations of gases (outgassing) producing a strong sulfur odor. 204 units. 2024-05-06
GE Medical Systems, LLC 510(k) number 2019-10-11 Class I Device Design Giraffe Incubator, Giraffe OmniBed, Giraffe Incubator Carestation, and Giraffe OmniBed Carestation Bedside panels and portholes can appear closed without being latched. Potential patient fall. 23,693 units 2024-08-15
GE Medical Systems, LLC 510(k) number 2018-09-25 Class II Process design Potential electric leakage affecting the user. 1,724 devices total 2020-07-13
GE Medical Systems, LLC 510(k) number 2018-09-25 Class II Process design Potential electric leakage affecting the user. 1,724 devices total 2020-07-13
GE Medical Systems, LLC 510(k) number 2018-09-25 Class II Process design Potential electric leakage affecting the user. 1,724 devices total 2020-07-13
GE Medical Systems, LLC 510(k) number 2018-09-25 Class II Process design Potential electric leakage affecting the user. 1,724 devices total 2020-07-13
GE Medical Systems, LLC 510(k) number 2013-01-08 Class I Process control Neonatal beds and incubator display boards may randomly overwrite stored information and radiant heater and oxygen set points upon power up or recovery from a power failure. 679 units 2013-07-10

Recalls

3 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2024-09-03 Class I Use error GE HealthCare has become aware that for certain Giraffe OmniBed and Giraffe OmniBed Carestation devices, the screw that secures the doors that cover the warmer heaters may not have been torqued to specification. This may lead to the doors b
2023-06-06 Class I Component design/selection Prior to current established manufacturing practices, higher levels of airborne formaldehyde exposure from newly manufactured incubators could be seen during clinical use that would rapidly decrease over a week. Affected customers were noti 224 units
2023-06-06 Class I Component design/selection Prior to current established manufacturing practices, higher levels of airborne formaldehyde exposure from newly manufactured incubators could be seen during clinical use that would rapidly decrease over a week. Affected customers were noti 769 units
2023-05-19 Class II Nonconforming Material/Component GE HealthCare has become aware of the potential that an incorrect type of secondary latch could have been installed on the northeast (NE) and/or northwest (NW) bedside panels for certain Giraffe OmniBed and Giraffe OmniBed Carestation devic 4,540 units
2023-05-19 Class II Nonconforming Material/Component GE HealthCare has become aware of the potential that an incorrect type of secondary latch could have been installed on the northeast (NE) and/or northwest (NW) bedside panels for certain Giraffe OmniBed and Giraffe OmniBed Carestation devic 18

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer