IsoAir
84 Inch System
Who Else Makes It
Concentrated in Guangdong (18), Jiangsu (13), Fujian (10). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jiangsu Saikang Medical Equipment Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 34 |
| Foshan Hongfeng Co., Ltd. | Foshan | Guangdong | Contract manufacturer | 24 |
| Cofoe Medical Technology Co., Ltd. | Changsha | Hunan | Contract manufacturer | 22 |
| Jiangyin Newrise Medical Equipment Co., Ltd. | Jiangyin | Jiangsu | Contract manufacturer | 10 |
| Xiamen Senyang Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 7 |
| SHL Healthcare Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Xiamen HOY Plastic Industrial Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 5 |
| Apex Medical (Kunshan) Corp. | Kunshan | Jiangsu | Contract manufacturer | 4 |
| Shenzhen Fitconn Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 4 |
| Boen Healthcare Co., Ltd. | Suzhou | Jiangsu | Specification developer | 263 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Dragon Medical Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 48 |
Showing 12 of 52. All 52 manufacturers in China registered for Mattress, Air Flotation, Alternating Pressure
Record
| Listed by | Stryker GmbH, Switzerland |
|---|---|
| FDA product code | FNM |
| Device type | Mattress, Air Flotation, Alternating Pressure |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5550 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2020-03-23 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | serial number |
| Storage | Storage environment temperature 40 to 60 °C; Storage environment atmospheric pressure 50 to 106 KiloPascal; Handling environment atmospheric pressure 70 to 106 KiloPascal; Storage environment humidity 10 to 95 % RH; Handling environment temperature 10 to 40 °C; Handling environment humidity 30 to 75 % RH |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 2941 | In distribution | |
| 2941 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| PressureGuard | Span-America Medical Systems, Inc. | 328 |
| Span-America | Span-America Medical Systems, Inc. | 286 |
| Medline | Medline Industries, Inc. | 228 |
| K-2oem ALT-Aire + | KAP Medical | 130 |
| SenTech | Tridien Medical | 129 |
| Mattress, Air Flotation, Alternating Pressure | Carilex Medical, Inc. | 118 |
| K-2 Kare-Zone | KAP Medical | 107 |
| K-4oem Aire-Float | KAP Medical | 90 |
| K-1oem ALT-Aire | KAP Medical | 72 |
| K-4 D³X | KAP Medical | 70 |
| Sizewise | Sizewise Rentals, L.L.C. | 68 |
| K-1 Derma-Kare | KAP Medical | 58 |
Showing 12 of 429. All products under Mattress, Air Flotation, Alternating Pressure
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K935949 | 1994-06-17 |
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Stryker GmbH | UDI-DI | 2020-08-12 | Class II | Nonconforming Material/Component | Connector between support surface and pump may be out of tolerance resulting in difficulty in removing the CPR connector causing a delay in resuscitation efforts for patients experiencing cardiac arrest and needing CPR | 110 units | 2021-04-02 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-10-31 | Class II | Release of Material/Component prior to receiving test results | Stryker has issued a voluntary recall of certain MV3 beds and Arise 1000EX mattresses because some of these products have been sold in close proximity, suggesting a potential intent for them to be used together. These products have not been | 297 units | |
| 2015-12-03 | Class II | Component design/selection | Potential for power cord to melt; hazards include electric shock and fire. | 2694 | 2017-05-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.