2 catalogue numbers from 2920, listed by Stryker GmbH, Switzerland, under Mattress, Air Flotation, Alternating Pressure. 52 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (18), Jiangsu (13), Fujian (10). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jiangsu Saikang Medical Equipment Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 34 |
| Foshan Hongfeng Co., Ltd. | Foshan | Guangdong | Contract manufacturer | 24 |
| Cofoe Medical Technology Co., Ltd. | Changsha | Hunan | Contract manufacturer | 22 |
| Jiangyin Newrise Medical Equipment Co., Ltd. | Jiangyin | Jiangsu | Contract manufacturer | 10 |
| Xiamen Senyang Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 7 |
| SHL Healthcare Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Xiamen HOY Plastic Industrial Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 5 |
| Apex Medical (Kunshan) Corp. | Kunshan | Jiangsu | Contract manufacturer | 4 |
| Shenzhen Fitconn Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 4 |
| Boen Healthcare Co., Ltd. | Suzhou | Jiangsu | Specification developer | 263 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Dragon Medical Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 48 |
Showing 12 of 52. All 52 manufacturers in China registered for Mattress, Air Flotation, Alternating Pressure
Record
| Listed by | Stryker GmbH, Switzerland |
|---|---|
| FDA product code | FNM |
| Device type | Mattress, Air Flotation, Alternating Pressure |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5550 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2016-09-24 |
| Record revised | 2018-03-29 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | serial number |
| Storage | Handling environment humidity 10 to 100 % RH; Storage environment humidity 10 to 100 % RH; Handling environment temperature -40 to 158 °F; Storage environment temperature -40 to 158 °F |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 2920 | In distribution | |
| 2920 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| PressureGuard | Span-America Medical Systems, Inc. | 328 |
| Span-America | Span-America Medical Systems, Inc. | 286 |
| Medline | Medline Industries, Inc. | 228 |
| K-2oem ALT-Aire + | KAP Medical | 130 |
| SenTech | Tridien Medical | 129 |
| Mattress, Air Flotation, Alternating Pressure | Carilex Medical, Inc. | 118 |
| K-2 Kare-Zone | KAP Medical | 107 |
| K-4oem Aire-Float | KAP Medical | 90 |
| K-1oem ALT-Aire | KAP Medical | 72 |
| K-4 D³X | KAP Medical | 70 |
| Sizewise | Sizewise Rentals, L.L.C. | 68 |
| K-1 Derma-Kare | KAP Medical | 58 |
Showing 12 of 429. All products under Mattress, Air Flotation, Alternating Pressure
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K935949 | 1994-06-17 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-10-31 | Class II | Release of Material/Component prior to receiving test results | Stryker has issued a voluntary recall of certain MV3 beds and Arise 1000EX mattresses because some of these products have been sold in close proximity, suggesting a potential intent for them to be used together. These products have not been | 297 units | |
| 2015-12-03 | Class II | Component design/selection | Potential for power cord to melt; hazards include electric shock and fire. | 2694 | 2017-05-24 |