BioFlo

BioFlo Midline with ENDEXO Technology 4F SL-10cm AST - Rapid Deployment Procedure Basic Kit

Registry build 21.09.26
12manufacturers in China registered for this device type
4catalogue numbers in this listing
5recalls on this code

Who Else Makes It

Concentrated in Shandong (3), Guangdong (3), Jiangsu (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FOZ
Manufacturer City Province Registered as Device types
Amsino Medical (Shanghai) Co., Ltd. Shanghai Shanghai Contract manufacturer 22
Bioxin Medical Co., Ltd. Weihai Shandong Contract manufacturer 8
Weihai Jierui Medical Products Co., Ltd. Weihai Shandong Contract manufacturer 3
Becton Dickinson Medical Devices Co., Ltd. Suzhou Suzhou Jiangsu Contract manufacturer 2
Jiangsu NEW Pentastar Medical Products Co., Ltd. Changzhou Jiangsu Exporter 146
Zhejiang Kindly Medical Devices Co., Ltd. Wenzhou Zhejiang Contract manufacturer 16
Terumo Medical Products (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 7
Shandong Ande Healthcare Apparatus Co., Ltd. Zibo Shandong Manufacturer 7
Jiangxi Sanxin Medtec Co., Ltd. Nanchang Jiangxi Manufacturer 6
Haolang Technology (Foshan) Limited Corporation Foshan Guangdong Contract manufacturer 6
Guangdong Baihe Medical Technology Co., Ltd. Foshan Guangdong Contract manufacturer 4
Foshan Special Medical Co., Ltd. Foshan Guangdong Manufacturer 3

Record

Regulatory record for BioFlo
Listed by AngioDynamics, Inc., United States
FDA product code FOZ
Device type Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days
Device class Class 2
Regulation 21 CFR 880.5200
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
Record published 2025-03-18

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Storage Storage environment temperature 20 to 25 °C
Packaging Box of 5
Sizes Catheter gauge 3 to 4 Fr; length 10 cm; outer diameter 1.02 to 1.4 mm; lumen/inner diameter 0.018 in

Catalogue Numbers

Catalogue numbers for BioFlo
Catalogue number Size Status
H965460330 Catheter Gauge 3 Fr In distribution
H965460420 Lumen/Inner Diameter 0.018 in In distribution
H965460320 Outer Diameter 1.02 mm In distribution
H965460430 Lumen/Inner Diameter 0.018 in In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arrow Teleflex Medical LLC 2,368
Cook Cook Incorporated 250
Cook Spectrum Cook Incorporated 225
Jelco ICU Medical, Inc 104
Medline Medline Industries, Inc. 95
Deltaven Fast Flash Delta Med SpA 77
Deltaven Delta Med SpA 73
PowerGlide Pro Bard Access Systems, Inc. 63
Peripheral Catheter Insertion Kit Bard Access Systems, Inc. 62
Able Central Venous Catheter Guangdong Baihe Medical Technology Co., Ltd. 62
Curaplex Bound Tree Medical, LLC 61
BD Cathena™ Safety IV Catheter Becton, Dickinson AND Company 59

Showing 12 of 285. All products under Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-05-04 Class II Process control Certain AngioDynamics PICC Kits contain BD PosiFlush SF Saline Flush Syringes which were recalled by BD Medical on April 16, 2020. 119723 eaches total 2023-08-23
2020-05-04 Class II Process control Certain AngioDynamics PICC Kits contain BD PosiFlush SF Saline Flush Syringes which were recalled by BD Medical on April 16, 2020. 119723 eaches total 2023-08-23
2018-05-10 Class II Material/Component Contamination A component of the kits might contain unsafe levels of bacterial endotoxins (pyrogens). 23 boxes 2020-05-13
2018-05-10 Class II Material/Component Contamination A component of the kits might contain unsafe levels of bacterial endotoxins (pyrogens). 190 boxes 2020-05-13
2018-05-10 Class II Material/Component Contamination A component of the kits might contain unsafe levels of bacterial endotoxins (pyrogens). 3 boxes 2020-05-13

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer