Introcan Safety® 3

Introcan Safety® 3 Closed IV Catheter 20 Ga. x 1.25 in., PUR, Winged

Registry build 21.09.26
12manufacturers in China registered for this device type
9catalogue numbers in this listing
12510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Shandong (3), Guangdong (3), Jiangsu (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FOZ
Manufacturer City Province Registered as Device types
Amsino Medical (Shanghai) Co., Ltd. Shanghai Shanghai Contract manufacturer 22
Bioxin Medical Co., Ltd. Weihai Shandong Contract manufacturer 8
Weihai Jierui Medical Products Co., Ltd. Weihai Shandong Contract manufacturer 3
Becton Dickinson Medical Devices Co., Ltd. Suzhou Suzhou Jiangsu Contract manufacturer 2
Jiangsu NEW Pentastar Medical Products Co., Ltd. Changzhou Jiangsu Exporter 146
Zhejiang Kindly Medical Devices Co., Ltd. Wenzhou Zhejiang Contract manufacturer 16
Terumo Medical Products (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 7
Shandong Ande Healthcare Apparatus Co., Ltd. Zibo Shandong Manufacturer 7
Jiangxi Sanxin Medtec Co., Ltd. Nanchang Jiangxi Manufacturer 6
Haolang Technology (Foshan) Limited Corporation Foshan Guangdong Contract manufacturer 6
Guangdong Baihe Medical Technology Co., Ltd. Foshan Guangdong Contract manufacturer 4
Foshan Special Medical Co., Ltd. Foshan Guangdong Manufacturer 3

Record

Regulatory record for Introcan Safety® 3
Listed by B. Braun Medical Inc., United States
FDA product code FOZ
Device type Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days
Device class Class 2
Regulation 21 CFR 880.5200
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer
Record published 2016-09-23
Record revised 2022-06-10 (version 12)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Packaging Carton of 4

Catalogue Numbers

Catalogue numbers for Introcan Safety® 3
Catalogue number Size Per pack Status
4251130-02 Catheter-Gauge : 20 50 In distribution
4251131-02 Catheter-Gauge : 18 50 In distribution
4251137-02 Catheter-Gauge : 20 50 In distribution
4251128-02 Catheter-Gauge : 22 50 In distribution
4251127-02 Catheter-Gauge : 24 50 In distribution
4251129-02 Catheter-Gauge : 20 50 In distribution
4251132-02 Catheter-Gauge : 18 50 In distribution
4251136-02 Catheter-Gauge : 16 50 In distribution
4251133-02 Catheter-Gauge : 16 50 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arrow Teleflex Medical LLC 2,368
Cook Cook Incorporated 250
Cook Spectrum Cook Incorporated 225
Jelco ICU Medical, Inc 104
Medline Medline Industries, Inc. 95
Deltaven Fast Flash Delta Med SpA 77
Deltaven Delta Med SpA 73
PowerGlide Pro Bard Access Systems, Inc. 63
Peripheral Catheter Insertion Kit Bard Access Systems, Inc. 62
Able Central Venous Catheter Guangdong Baihe Medical Technology Co., Ltd. 62
Curaplex Bound Tree Medical, LLC 61
BD Cathena™ Safety IV Catheter Becton, Dickinson AND Company 59

Showing 12 of 285. All products under Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K253235 2026-05-15
K241845 2024-07-26
K220756 2022-06-23
K220626 2022-05-14
K213664 2022-02-11
K213085 2021-10-25
K192676 2020-04-01
K182870 2019-03-07
K023253 2003-05-06
K020785 2002-08-28
K982805 1999-01-14
K970736 1998-12-16

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of Introcan Safety® 3
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
B. Braun Medical Inc. UDI-DI 2025-02-17 Class II Process control Increased risk for valve housing detachment causing leakage. 28,200 units

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2022-09-01 Class II Process control Potential for leakage at the catheter hub. 94,000 US

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer