Nipro SafeTouch™ Safety Scalp Vein Set

Catalogue number SPR+23G19, listed by Nipro Medical Corporation, United States, under Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days. 12 manufacturers in China are registered for this product code.

Registry build 21.09.26
12manufacturers in China registered for this device type
1catalogue number
8510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Shandong (3), Guangdong (3), Jiangsu (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FOZ
Manufacturer City Province Registered as Device types
Amsino Medical (Shanghai) Co., Ltd. Shanghai Shanghai Contract manufacturer 22
Bioxin Medical Co., Ltd. Weihai Shandong Contract manufacturer 8
Weihai Jierui Medical Products Co., Ltd. Weihai Shandong Contract manufacturer 3
Becton Dickinson Medical Devices Co., Ltd. Suzhou Suzhou Jiangsu Contract manufacturer 2
Jiangsu NEW Pentastar Medical Products Co., Ltd. Changzhou Jiangsu Exporter 146
Zhejiang Kindly Medical Devices Co., Ltd. Wenzhou Zhejiang Contract manufacturer 16
Terumo Medical Products (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 7
Shandong Ande Healthcare Apparatus Co., Ltd. Zibo Shandong Manufacturer 7
Jiangxi Sanxin Medtec Co., Ltd. Nanchang Jiangxi Manufacturer 6
Haolang Technology (Foshan) Limited Corporation Foshan Guangdong Contract manufacturer 6
Guangdong Baihe Medical Technology Co., Ltd. Foshan Guangdong Contract manufacturer 4
Foshan Special Medical Co., Ltd. Foshan Guangdong Manufacturer 3

Record

Regulatory record for Nipro SafeTouch™ Safety Scalp Vein Set
Listed by Nipro Medical Corporation, United States
FDA product code FOZ
Device type Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days
Device class Class 2
Regulation 21 CFR 880.5200
Establishment Complaint-file establishment, Exporter
Record published 2016-09-16
Record revised 2018-03-29 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging Pack of 50, pack of 10

Catalogue Numbers

Catalogue numbers for Nipro SafeTouch™ Safety Scalp Vein Set
Catalogue number Size Status
SPR+23G19 NeedleLength : 3/4 Inch In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arrow Teleflex Medical LLC 2,368
Cook Cook Incorporated 250
Cook Spectrum Cook Incorporated 225
Jelco ICU Medical, Inc 104
Medline Medline Industries, Inc. 95
Deltaven Fast Flash Delta Med SpA 77
Deltaven Delta Med SpA 73
PowerGlide Pro Bard Access Systems, Inc. 63
Peripheral Catheter Insertion Kit Bard Access Systems, Inc. 62
Able Central Venous Catheter Guangdong Baihe Medical Technology Co., Ltd. 62
Curaplex Bound Tree Medical, LLC 61
BD Cathena™ Safety IV Catheter Becton, Dickinson AND Company 59

Showing 12 of 285. All products under Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K161681 2017-03-08
K140136 2014-02-14
K132153 2013-12-05
K113429 2012-03-12
K032777 2003-11-14
K022756 2002-10-18
K013287 2001-12-03
K011297 2001-06-20

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2014-04-01 Class III Process control Device has the potential to have torn wings. 160,000 pieces. 2016-12-14
2013-05-04 Class II Component design/selection There is a possibility of a crack in the CP luer connector. The position of the crack is at the connection site of the CP luer connector and the tubing. The crack could cause or contribute to leakage of fluids. 176,000 pieces 2015-03-02

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer