Wolf-PAK Self Safe IV Catheter
IV safety catheter
Who Else Makes It
Concentrated in Shandong (3), Guangdong (3), Jiangsu (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amsino Medical (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 22 |
| Bioxin Medical Co., Ltd. | Weihai | Shandong | Contract manufacturer | 8 |
| Weihai Jierui Medical Products Co., Ltd. | Weihai | Shandong | Contract manufacturer | 3 |
| Becton Dickinson Medical Devices Co., Ltd. Suzhou | Suzhou | Jiangsu | Contract manufacturer | 2 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Zhejiang Kindly Medical Devices Co., Ltd. | Wenzhou | Zhejiang | Contract manufacturer | 16 |
| Terumo Medical Products (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 7 |
| Shandong Ande Healthcare Apparatus Co., Ltd. | Zibo | Shandong | Manufacturer | 7 |
| Jiangxi Sanxin Medtec Co., Ltd. | Nanchang | Jiangxi | Manufacturer | 6 |
| Haolang Technology (Foshan) Limited Corporation | Foshan | Guangdong | Contract manufacturer | 6 |
| Guangdong Baihe Medical Technology Co., Ltd. | Foshan | Guangdong | Contract manufacturer | 4 |
| Foshan Special Medical Co., Ltd. | Foshan | Guangdong | Manufacturer | 3 |
Record
| Listed by | Delta Med SpA, Italy |
|---|---|
| FDA product code | FOZ |
| Device type | Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5200 |
| Establishment | Contract manufacturer, Manufacturer, Exporter |
| Record published | 2020-04-30 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Packaging | Case of 50, box of 4 |
| Sizes | Length 25 mm; outer diameter 1 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 3738760 | Length 25 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arrow | Teleflex Medical LLC | 2,368 |
| Cook | Cook Incorporated | 250 |
| Cook Spectrum | Cook Incorporated | 225 |
| Jelco | ICU Medical, Inc | 104 |
| Medline | Medline Industries, Inc. | 95 |
| Deltaven Fast Flash | Delta Med SpA | 77 |
| Deltaven | Delta Med SpA | 73 |
| PowerGlide Pro | Bard Access Systems, Inc. | 63 |
| Peripheral Catheter Insertion Kit | Bard Access Systems, Inc. | 62 |
| Able Central Venous Catheter | Guangdong Baihe Medical Technology Co., Ltd. | 62 |
| Curaplex | Bound Tree Medical, LLC | 61 |
| BD Cathena™ Safety IV Catheter | Becton, Dickinson AND Company | 59 |
Showing 12 of 285. All products under Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K200373 | 2020-08-26 |
| K171530 | 2017-12-21 |
| K121007 | 2012-12-28 |
Recalls
11 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2021-06-21 | Class II | Process control | Problems related to the sterilization of the medical devices; possible missing sterility of the medical device | 20,000 units |
| 2021-06-21 | Class II | Process control | Problems related to the sterilization of the medical devices; possible missing sterility of the medical device | |
| 2021-06-21 | Class II | Process control | Problems related to the sterilization of the medical devices; possible missing sterility of the medical device | 30,900 units |
| 2021-06-21 | Class II | Process control | Problems related to the sterilization of the medical devices; possible missing sterility of the medical device | 14,000 units |
| 2021-06-21 | Class II | Process control | Problems related to the sterilization of the medical devices; possible missing sterility of the medical device | 203,680 units |
| 2021-06-21 | Class II | Process control | Problems related to the sterilization of the medical devices; possible missing sterility of the medical device | 40,000 units |
| 2021-06-21 | Class II | Process control | Problems related to the sterilization of the medical devices; possible missing sterility of the medical device | 1400 units |
| 2021-06-21 | Class II | Process control | Problems related to the sterilization of the medical devices; possible missing sterility of the medical device | 229,320 units |
| 2021-06-21 | Class II | Process control | Problems related to the sterilization of the medical devices; possible missing sterility of the medical device | |
| 2021-06-21 | Class II | Process control | Problems related to the sterilization of the medical devices; possible missing sterility of the medical device | 5000 units |
| 2021-06-21 | Class II | Process control | Problems related to the sterilization of the medical devices; possible missing sterility of the medical device | 10,000 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.