Hospira

LIFESHIELD LATEX-FREE HEMA Y-TYPE BLOOD SET, Nonvented, 79 Inch with 170 Micron Filter, Prepierced Injection Site and Secure Lock Non-DEHP

Registry build 21.09.26
49manufacturers in China registered for this device type
24catalogue numbers in this listing
27510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Zhejiang (12), Jiangsu (11), Shanghai (10). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FPA
Manufacturer City Province Registered as Device types
Promisemed Hangzhou Meditech Co., Ltd. Hangzhou Zhejiang Contract manufacturer 21
Hantech Medical Device Co., Ltd. Cixi Zhejiang Contract manufacturer 18
Forefront Medical Technology (Jiangsu) Co., Ltd. Changzhou Jiangsu Contract manufacturer 14
BQ Plus Medical Co., Ltd. Songjiang Shanghai Contract manufacturer 13
Ningbo Tianyi Medical Appliance Co., Ltd. Ningbo Zhejiang Contract manufacturer 11
Anhui Tiankang Medical Technology Co., Ltd. Tianchang Anhui Contract manufacturer 9
Anhui Kangda Medical Products Co., Ltd. Tianchang Anhui Contract manufacturer 7
JDI Electronics Factory Dongguan Guangdong Contract manufacturer 7
Yangzhou Xingwei Medical Technology Co., Ltd. Yangzhou Jiangsu Contract manufacturer 5
Wenzhou K.L.F. Medical Plastics Co., Ltd. Wenzhou Zhejiang Contract manufacturer 4
Advance Technology Ltd Shenzhen Guangdong Contract manufacturer 3
Weihai Jierui Medical Products Co., Ltd. Weihai Shandong Contract manufacturer 3

Showing 12 of 49. All 49 manufacturers in China registered for Set, Administration, Intravascular

Record

Regulatory record for Hospira
Listed by ICU Medical, Inc, United States
FDA product code FPA
Device type Set, Administration, Intravascular
Device class Class 2
Regulation 21 CFR 880.5440
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K141789
Record published 2016-09-01
Record revised 2025-11-24 (version 8)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Storage Special storage condition: Room Temperature. Avoid Excessive Heat. Protect from Freezing
Packaging Case of 48, case of 50, case of 20, case of 120, case of 24
Sizes Length 5 to 145 in
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Hospira
Catalogue number Size Status
451058 Approximate priming volume : 3.8 Milliliter In distribution
2065628 Length 8 in In distribution
1990339 Approximate priming volume : 1.0 Milliliter In distribution
1422028 Drop Size : 20 Drops / Milliliter In distribution
1269402 Length 80 in In distribution
1336048 Length 60 in In distribution
1114148 Length 40 in In distribution
1968228 Approximate priming volume : 13 Milliliter In distribution
1159248 Approximate priming volume : 130 Milliliter In distribution
1269328 Length 79 in In distribution
1269965 Drop Size : 10 Drops / Milliliter In distribution
1920948 Length 80 in In distribution
460258 Drop Size : 10 Drops / Milliliter In distribution
1195448 Approximate priming volume : 7 Milliliter In distribution
1990239 Approximate priming volume : 0.8 Milliliter In distribution
1990139 Approximate priming volume : 1.01 Milliliter In distribution
469301 Approximate priming volume : 12 Milliliter In distribution
1171628 Approximate priming volume : 1.1 Milliliter In distribution
1154928 Approximate priming volume : 0.6 Milliliter In distribution
1494928 Drop Size : 10 Drops / Milliliter In distribution
1972128 Drop Size : 15 Drops / Milliliter In distribution
303948 Length 105 in In distribution
646401 Approximate priming volume : 3 Milliliter In distribution
1134920 Length 82 in In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
ICU Medical ICU Medical, Inc 529
Codan Codan US Corp. 510
Vygon Vygon Corp. 355
Port Access Needle Bard Access Systems, Inc. 341
Set, Administration, Intravascular Mps Medical, Inc. 291
Alaris, SmartSite BD Switzerland Sàrl 266
IV Administration Set B. Braun Medical Inc. 242
Medex ICU Medical, Inc 237
Extension Set B. Braun Medical Inc. 171
MaxGuard BD Switzerland Sàrl 150
Medline Medline Industries, Inc. 148
Centurion Centurion Medical Products Corporation 145

Showing 12 of 768. All products under Set, Administration, Intravascular

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K250616 2025-06-05
K151969 2016-01-19
K100576 2010-12-17
K100434 2010-07-09
K090189 2009-04-10
K082806 2009-04-06
K081361 2008-08-28
K070532 2007-03-20
K053106 2006-01-10
K051437 2005-08-03
K042182 2004-09-01
K040710 2004-08-11
K041410 2004-07-28
K033290 2004-04-12
K021692 2003-12-04
K003513 2001-01-11
K000472 2000-05-10
K974589 1998-01-09
K973167 1997-11-17
K972712 1997-10-01
K970855 1997-06-24
K954813 1995-11-29
K941190 1995-01-31
K940296 1994-02-22
K915571 1992-09-21
K910546 1991-04-29
K840273 1984-03-06

Recalls

37 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-05-12 Not classified Process control Intravascular administration tubing set drip chambers may have black specks potentially due to the plastic molding process leaving discolored polyvinyl chloride (PVC) material within the drip chamber wall. The presence of discoloration and 163,500,199
2026-05-12 Not classified Process control Intravascular administration tubing set drip chambers may have black specks potentially due to the plastic molding process leaving discolored polyvinyl chloride (PVC) material within the drip chamber wall. The presence of discoloration and 100,712,657
2026-05-12 Not classified Process control Intravascular administration tubing set drip chambers may have black specks potentially due to the plastic molding process leaving discolored polyvinyl chloride (PVC) material within the drip chamber wall that does not enter the fluid path, 107,800
2025-12-19 Class II Process control Needle free access device intended as accessory to vascular access used in hemodialysis or accessory to intravascular administration sets has a silicone seal which may bulge at the top, separate from the body, tear; may result in fluid leak 14,684,607 items
2025-08-06 Class II Under Investigation by firm Certain CADD 50 mL and 100 mL Medication Cassette Reservoirs may exhibit weakened medication bag welds along the bag perimeter inside the plastic housing. This could result in medication leakage along the bag perimeter. 289098 units
2025-08-06 Class II Under Investigation by firm Certain CADD 50 mL and 100 mL Medication Cassette Reservoirs may exhibit weakened medication bag welds along the bag perimeter inside the plastic housing. This could result in medication leakage along the bag perimeter. 29811 units
2025-08-06 Class II Under Investigation by firm Certain CADD 50 mL and 100 mL Medication Cassette Reservoirs may exhibit weakened medication bag welds along the bag perimeter inside the plastic housing. This could result in medication leakage along the bag perimeter. 987911 units
2025-08-06 Class II Under Investigation by firm Certain CADD 50 mL and 100 mL Medication Cassette Reservoirs may exhibit weakened medication bag welds along the bag perimeter inside the plastic housing. This could result in medication leakage along the bag perimeter. 265500 units
2025-08-06 Class II Under Investigation by firm Certain CADD 50 mL and 100 mL Medication Cassette Reservoirs may exhibit weakened medication bag welds along the bag perimeter inside the plastic housing. This could result in medication leakage along the bag perimeter. 211750 units
2025-08-06 Class II Under Investigation by firm Certain CADD 50 mL and 100 mL Medication Cassette Reservoirs may exhibit weakened medication bag welds along the bag perimeter inside the plastic housing. This could result in medication leakage along the bag perimeter. 15546 units
2022-08-01 Class II Process control Due to a manufacturing defect which results in a visible gap between the connector’s top and bottom housing. Total of all affected units = 5,795,989 units
2022-08-01 Class II Process control Due to a manufacturing defect which results in a visible gap between the connector’s top and bottom housing. Total of all affected units = 5,795,989 units
2022-08-01 Class II Process control Due to a manufacturing defect which results in a visible gap between the connector’s top and bottom housing. Total of all affected units = 5,795,989 units
2022-08-01 Class II Process control Due to a manufacturing defect which results in a visible gap between the connector’s top and bottom housing. Total of all affected units = 5,795,989 units
2021-03-16 Class II Component design/selection Due to molding defect, there is a potential that certain lots of spinning and non-spinning Sprios male luers may exhibit small amounts of leakage in the inactivated position.
2021-03-16 Class II Component design/selection Due to molding defect, there is a potential that certain lots of spinning and non-spinning Sprios male luers may exhibit small amounts of leakage in the inactivated position.
2021-03-16 Class II Component design/selection Due to molding defect, there is a potential that certain lots of spinning and non-spinning Sprios male luers may exhibit small amounts of leakage in the inactivated position.
2021-03-16 Class II Component design/selection Due to molding defect, there is a potential that certain lots of spinning and non-spinning Sprios male luers may exhibit small amounts of leakage in the inactivated position.
2021-03-16 Class II Component design/selection Due to molding defect, there is a potential that certain lots of spinning and non-spinning Sprios male luers may exhibit small amounts of leakage in the inactivated position.
2020-08-31 Class II Process control Potential for spinning versions of male luers to exhibit leaks due to a molding defect. Fluid leakage may potentially cause delay of infusion, contamination of the fluid path, exposure to hazardous medications, blood loss, exposure to patie 19850
2020-08-31 Class II Process control Potential for spinning versions of male luers to exhibit leaks due to a molding defect. Fluid leakage may potentially cause delay of infusion, contamination of the fluid path, exposure to hazardous medications, blood loss, exposure to patie 1856578
2020-08-31 Class II Process control Potential for spinning versions of male luers to exhibit leaks due to a molding defect. Fluid leakage may potentially cause delay of infusion, contamination of the fluid path, exposure to hazardous medications, blood loss, exposure to patie 217522
2020-08-31 Class II Process control Potential for spinning versions of male luers to exhibit leaks due to a molding defect. Fluid leakage may potentially cause delay of infusion, contamination of the fluid path, exposure to hazardous medications, blood loss, exposure to patie 33900
2020-08-31 Class II Process control Potential for spinning versions of male luers to exhibit leaks due to a molding defect. Fluid leakage may potentially cause delay of infusion, contamination of the fluid path, exposure to hazardous medications, blood loss, exposure to patie 37000
2020-08-31 Class II Process control Potential for spinning versions of male luers to exhibit leaks due to a molding defect. Fluid leakage may potentially cause delay of infusion, contamination of the fluid path, exposure to hazardous medications, blood loss, exposure to patie 55000
2020-08-31 Class II Process control Potential for spinning versions of male luers to exhibit leaks due to a molding defect. Fluid leakage may potentially cause delay of infusion, contamination of the fluid path, exposure to hazardous medications, blood loss, exposure to patie 325
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11
2020-07-06 Class II Process control Identification of a potential manufacturing defect on the internal surface of the NanoClave within specific lots of NanoClave sets, which may inhibit a proper seal with the NanoClave spike. Total of all products (Listed #1 thru 101) = 304735 units 2023-05-11

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer