Lifeguard
LIFEGUARD Safety Needle
Who Else Makes It
Concentrated in Zhejiang (12), Jiangsu (11), Shanghai (10). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Promisemed Hangzhou Meditech Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 21 |
| Hantech Medical Device Co., Ltd. | Cixi | Zhejiang | Contract manufacturer | 18 |
| Forefront Medical Technology (Jiangsu) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 14 |
| BQ Plus Medical Co., Ltd. | Songjiang | Shanghai | Contract manufacturer | 13 |
| Ningbo Tianyi Medical Appliance Co., Ltd. | Ningbo | Zhejiang | Contract manufacturer | 11 |
| Anhui Tiankang Medical Technology Co., Ltd. | Tianchang | Anhui | Contract manufacturer | 9 |
| Anhui Kangda Medical Products Co., Ltd. | Tianchang | Anhui | Contract manufacturer | 7 |
| JDI Electronics Factory | Dongguan | Guangdong | Contract manufacturer | 7 |
| Yangzhou Xingwei Medical Technology Co., Ltd. | Yangzhou | Jiangsu | Contract manufacturer | 5 |
| Wenzhou K.L.F. Medical Plastics Co., Ltd. | Wenzhou | Zhejiang | Contract manufacturer | 4 |
| Advance Technology Ltd | Shenzhen | Guangdong | Contract manufacturer | 3 |
| Weihai Jierui Medical Products Co., Ltd. | Weihai | Shandong | Contract manufacturer | 3 |
Showing 12 of 49. All 49 manufacturers in China registered for Set, Administration, Intravascular
Record
| Listed by | Navilyst Medical, Inc., United States |
|---|---|
| FDA product code | FPA |
| Device type | Set, Administration, Intravascular |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5440 |
| 510(k) | K013871 |
| Record published | 2016-09-20 |
| Record revised | 2026-06-16 (version 6) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Sizes | Needle gauge 19 to 22 G; length 0.5 to 1.5 in |
| Distribution end date | 2026-06-15 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| LG-19-75 | Needle Gauge 19 G | 20 | Withdrawn |
| LG-20-150 | Needle Gauge 20 G | 20 | Withdrawn |
| LG-20-50 | Needle Gauge 20 G | 20 | Withdrawn |
| LG-22-50 | Length 0.5 in | 20 | Withdrawn |
| LG-20-75 | Needle Gauge 20 G | 20 | Withdrawn |
| LG-20-100 | Length 1 in | 20 | Withdrawn |
| LG-22-75 | Needle Gauge 22 G | 20 | Withdrawn |
| LG-19-100 | Needle Gauge 19 G | 20 | Withdrawn |
| LG-22-100 | Length 1 in | 20 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| ICU Medical | ICU Medical, Inc | 529 |
| Codan | Codan US Corp. | 510 |
| Vygon | Vygon Corp. | 355 |
| Port Access Needle | Bard Access Systems, Inc. | 341 |
| Set, Administration, Intravascular | Mps Medical, Inc. | 291 |
| Alaris, SmartSite | BD Switzerland Sàrl | 266 |
| IV Administration Set | B. Braun Medical Inc. | 242 |
| Medex | ICU Medical, Inc | 237 |
| Extension Set | B. Braun Medical Inc. | 171 |
| MaxGuard | BD Switzerland Sàrl | 150 |
| Medline | Medline Industries, Inc. | 148 |
| Centurion | Centurion Medical Products Corporation | 145 |
Showing 12 of 768. All products under Set, Administration, Intravascular
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Vygon MFG | 510(k) number | 2017-07-24 | Class II | Under Investigation by firm | Vygon is conducting a voluntary recall of the products and lots listed in this recall, being initiated because our Tyvek supplier has notified Vygon of issues with their product, specifically the Tyvek may not be coated completely causing g | 396 units | 2019-11-07 |
| Vygon MFG | 510(k) number | 2013-01-21 | Class II | Under Investigation by firm | The label on the device states that the item number is CLGY-2210 when the item number on the device label should read CLGY-2010. This is a 20Ga Huber needle set; however, the product label states the pouch contains a 22Ga set. | 2340 | 2013-09-10 |
| Vygon MFG | 510(k) number | 2010-11-16 | Not classified | Vendor change control | Routine testing conducted to challenge the success of sterilization was not fully completed for sterile products. | 72 units | 2012-05-01 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.