Namic

MTO Protection Sta.w/Bif.saline Line PG

Registry build 21.09.26
49manufacturers in China registered for this device type
43catalogue numbers in this listing
1510(k) clearance

Who Else Makes It

Concentrated in Zhejiang (12), Jiangsu (11), Shanghai (10). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FPA
Manufacturer City Province Registered as Device types
Promisemed Hangzhou Meditech Co., Ltd. Hangzhou Zhejiang Contract manufacturer 21
Hantech Medical Device Co., Ltd. Cixi Zhejiang Contract manufacturer 18
Forefront Medical Technology (Jiangsu) Co., Ltd. Changzhou Jiangsu Contract manufacturer 14
BQ Plus Medical Co., Ltd. Songjiang Shanghai Contract manufacturer 13
Ningbo Tianyi Medical Appliance Co., Ltd. Ningbo Zhejiang Contract manufacturer 11
Anhui Tiankang Medical Technology Co., Ltd. Tianchang Anhui Contract manufacturer 9
Anhui Kangda Medical Products Co., Ltd. Tianchang Anhui Contract manufacturer 7
JDI Electronics Factory Dongguan Guangdong Contract manufacturer 7
Yangzhou Xingwei Medical Technology Co., Ltd. Yangzhou Jiangsu Contract manufacturer 5
Wenzhou K.L.F. Medical Plastics Co., Ltd. Wenzhou Zhejiang Contract manufacturer 4
Advance Technology Ltd Shenzhen Guangdong Contract manufacturer 3
Weihai Jierui Medical Products Co., Ltd. Weihai Shandong Contract manufacturer 3

Showing 12 of 49. All 49 manufacturers in China registered for Set, Administration, Intravascular

Record

Regulatory record for Namic
Listed by Medline Industries, Inc., United States
FDA product code FPA
Device type Set, Administration, Intravascular
Device class Class 2
Regulation 21 CFR 880.5440
Record published 2021-07-26
Record revised 2024-10-14 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Ethylene Oxide
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date
Packaging Box of 25, box of 10, box of 5, box of 20
Sizes Length 48 to 135 in

Catalogue Numbers

Catalogue numbers for Namic
Catalogue number Size Per pack Status
91300009 Length 108 in In distribution
90500070 In distribution
80427035 FALSE 150 In distribution
90500060 Length 72 in In distribution
99000070 Length 135 in In distribution
80427009 FALSE 150 In distribution
91300007 Length 108 in In distribution
94000904 In distribution
99000069 Length 135 in In distribution
64000936 In distribution
80015221 FALSE 100 In distribution
91300005 Length 72 in In distribution
80400039 FALSE 100 In distribution
64000944 In distribution
94000954 In distribution
64000130 In distribution
64000935 In distribution
80029130 FALSE 150 In distribution
91300026 Length 72 in In distribution
80518491 FALSE 250 In distribution
80427013 FALSE 150 In distribution
80427007 FALSE 150 In distribution
91300035 Length 72 in In distribution
91300021 Length 72 in In distribution
91300013 Length 48 in In distribution
91300004 Length 72 in In distribution
80427040 FALSE 150 In distribution
91300040 Length 72 in In distribution
64000934 In distribution
80427026 FALSE 50 In distribution
90500065 In distribution
94000952 In distribution
80427006 FALSE 150 In distribution
81300021 FALSE 100 In distribution
91300012 Length 48 in In distribution
80427440 FALSE 150 In distribution
91300001 Length 48 in In distribution
64000945 In distribution
80427004 FALSE 150 In distribution
91300052 Length 72 in In distribution
91300011 Length 48 in In distribution
91300020 In distribution
80427052 FALSE 150 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
ICU Medical ICU Medical, Inc 529
Codan Codan US Corp. 510
Vygon Vygon Corp. 355
Port Access Needle Bard Access Systems, Inc. 341
Set, Administration, Intravascular Mps Medical, Inc. 291
Alaris, SmartSite BD Switzerland Sàrl 266
IV Administration Set B. Braun Medical Inc. 242
Medex ICU Medical, Inc 237
Extension Set B. Braun Medical Inc. 171
MaxGuard BD Switzerland Sàrl 150
Medline Medline Industries, Inc. 148
Centurion Centurion Medical Products Corporation 145

Showing 12 of 768. All products under Set, Administration, Intravascular

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K170002 2017-09-19

Recalls Naming This Product

2 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of Namic
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Medline Industries, LP – Northfield UDI-DI 2024-12-16 Class I Under Investigation by firm Fluid Delivery Sets were incorrectly assembled with a white macro drip chamber instead of the required grey micro drip chamber. The macro drip chamber delivers three times more fluid per drop than the micro drip chamber. 13,600 units
Medline Industries, LP – Northfield UDI-DI 2024-03-12 Class II Process control Products have a lack of sterility assurance. 50 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer