Smart Port CT
Smart Port CT Single Titanium Port System with Attachable 8.0F x 66cm Polyurethane Catheter and 8 F Introducer Kit (with Valved Introducer and Non-Filled Suture Holes)
Who Else Makes It
Concentrated in Zhejiang (12), Jiangsu (11), Shanghai (10). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Promisemed Hangzhou Meditech Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 21 |
| Hantech Medical Device Co., Ltd. | Cixi | Zhejiang | Contract manufacturer | 18 |
| Forefront Medical Technology (Jiangsu) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 14 |
| BQ Plus Medical Co., Ltd. | Songjiang | Shanghai | Contract manufacturer | 13 |
| Ningbo Tianyi Medical Appliance Co., Ltd. | Ningbo | Zhejiang | Contract manufacturer | 11 |
| Anhui Tiankang Medical Technology Co., Ltd. | Tianchang | Anhui | Contract manufacturer | 9 |
| Anhui Kangda Medical Products Co., Ltd. | Tianchang | Anhui | Contract manufacturer | 7 |
| JDI Electronics Factory | Dongguan | Guangdong | Contract manufacturer | 7 |
| Yangzhou Xingwei Medical Technology Co., Ltd. | Yangzhou | Jiangsu | Contract manufacturer | 5 |
| Wenzhou K.L.F. Medical Plastics Co., Ltd. | Wenzhou | Zhejiang | Contract manufacturer | 4 |
| Advance Technology Ltd | Shenzhen | Guangdong | Contract manufacturer | 3 |
| Weihai Jierui Medical Products Co., Ltd. | Weihai | Shandong | Contract manufacturer | 3 |
Showing 12 of 49. All 49 manufacturers in China registered for Set, Administration, Intravascular
Record
| Listed by | AngioDynamics, Inc., United States |
|---|---|
| FDA product code | FPA |
| Device type | Set, Administration, Intravascular |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5440 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K062414 |
| Record published | 2024-07-23 |
| Record revised | 2024-07-23 (version 8) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 10 to 27 °C |
| Sizes | Catheter gauge 7.5 to 9.6 Fr; outer diameter 2.5 to 3.2 mm; length 66 cm; lumen/inner diameter 1.4 to 1.6 mm |
| Distribution end date | 2024-07-19 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| H787CT96STSA0 | Catheter Gauge 9.6 Fr | In distribution |
| H787CT80STPD0 | Outer Diameter 2.7 mm | In distribution |
| H787CT96STSDNF0 | Lumen/Inner Diameter 1.6 mm | In distribution |
| H787CT96STSDNFVI1 | Length 66 cm | In distribution |
| CT80STPD-NFVI | Lumen/Inner Diameter 1.5 mm | In distribution |
| H787CT80STPAVI1 | Catheter Gauge 8 Fr | In distribution |
| H787CT80STPA0 | Length 66 cm | In distribution |
| H787CT75STSA0 | Outer Diameter 2.5 mm | In distribution |
| H787CT80STPDVI1 | Outer Diameter 2.7 mm | In distribution |
| CT96STSD-NFVI | Outer Diameter 3.2 mm | Withdrawn |
| CT96STSD | Outer Diameter 3.2 mm | Withdrawn |
| CT75STSD-VI | Lumen/Inner Diameter 1.4 mm | Withdrawn |
| CT80STPD | Length 66 cm | Withdrawn |
| CT75STSD-NFVI | Outer Diameter 2.5 mm | Withdrawn |
| CT96STSA | Catheter Gauge 9.6 Fr | Withdrawn |
| CT80STPA-VI | Lumen/Inner Diameter 1.5 mm | Withdrawn |
| CT75STSA | Lumen/Inner Diameter 1.4 mm | Withdrawn |
| CT96STSD-VI | Catheter Gauge 9.6 Fr | Withdrawn |
| CT96STSA-VI | Outer Diameter 3.2 mm | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| ICU Medical | ICU Medical, Inc | 529 |
| Codan | Codan US Corp. | 510 |
| Vygon | Vygon Corp. | 355 |
| Port Access Needle | Bard Access Systems, Inc. | 341 |
| Set, Administration, Intravascular | Mps Medical, Inc. | 291 |
| Alaris, SmartSite | BD Switzerland Sàrl | 266 |
| IV Administration Set | B. Braun Medical Inc. | 242 |
| Medex | ICU Medical, Inc | 237 |
| Extension Set | B. Braun Medical Inc. | 171 |
| MaxGuard | BD Switzerland Sàrl | 150 |
| Medline | Medline Industries, Inc. | 148 |
| Centurion | Centurion Medical Products Corporation | 145 |
Showing 12 of 768. All products under Set, Administration, Intravascular
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K072375 | 2007-12-13 |
| K051142 | 2005-07-13 |
| K953825 | 1996-02-26 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| AngioDynamics, Inc. | 510(k) number | 2021-02-22 | Class II | Under Investigation by firm | AngioDynamics, Inc. is recalling a specific batch of AngioDynamics Implantable Infusion Port kits and Valved introducers that may have potential for compromised sterility of the device. Only the specific product/lot of the kit identified be | 267 kits | 2022-07-19 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2017-01-13 | Class II | Under Investigation by firm | The product has the potential to be non-sterile as it was not packaged in accordance to specification. | 8 boxes/25 units | 2018-06-25 |
| 2013-11-25 | Class II | Device Design | Navilyst Medical has recalled a Port Kit with Access Infusion Set due to a possible breach of sterilization barrier. | 920 Total kits | 2017-03-10 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.