Stat 2

Stat 2 Primary Administrative SET Gravity Flow Controller

Registry build 21.09.26
49manufacturers in China registered for this device type
14catalogue numbers in this listing
13recalls on this code

Who Else Makes It

Concentrated in Zhejiang (12), Jiangsu (11), Shanghai (10). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FPA
Manufacturer City Province Registered as Device types
Promisemed Hangzhou Meditech Co., Ltd. Hangzhou Zhejiang Contract manufacturer 21
Hantech Medical Device Co., Ltd. Cixi Zhejiang Contract manufacturer 18
Forefront Medical Technology (Jiangsu) Co., Ltd. Changzhou Jiangsu Contract manufacturer 14
BQ Plus Medical Co., Ltd. Songjiang Shanghai Contract manufacturer 13
Ningbo Tianyi Medical Appliance Co., Ltd. Ningbo Zhejiang Contract manufacturer 11
Anhui Tiankang Medical Technology Co., Ltd. Tianchang Anhui Contract manufacturer 9
Anhui Kangda Medical Products Co., Ltd. Tianchang Anhui Contract manufacturer 7
JDI Electronics Factory Dongguan Guangdong Contract manufacturer 7
Yangzhou Xingwei Medical Technology Co., Ltd. Yangzhou Jiangsu Contract manufacturer 5
Wenzhou K.L.F. Medical Plastics Co., Ltd. Wenzhou Zhejiang Contract manufacturer 4
Advance Technology Ltd Shenzhen Guangdong Contract manufacturer 3
Weihai Jierui Medical Products Co., Ltd. Weihai Shandong Contract manufacturer 3

Showing 12 of 49. All 49 manufacturers in China registered for Set, Administration, Intravascular

Record

Regulatory record for Stat 2
Listed by ConMed Corporation, United States
FDA product code FPA
Device type Set, Administration, Intravascular
Device class Class 2
Regulation 21 CFR 880.5440
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2016-09-24
Record revised 2023-08-07 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Contains natural rubber latex
Label carries lot or batch number, expiry date
Storage Storage environment temperature 10 to 32 °C; Storage environment temperature 50 to 90 °F
Packaging Box of 48, box of 60, box of 1000
Distribution end date 2023-08-04

Catalogue Numbers

Catalogue numbers for Stat 2
Catalogue number Size Per pack Status
S2V-60 48 Withdrawn
S2-12 60 Withdrawn
P-S2-12 N 60 Withdrawn
S2V-60 N 48 Withdrawn
S2V-20 48 Withdrawn
S2-12 N 48 Withdrawn
P-S2-12 60 Withdrawn
P-S2V-20 N 48 Withdrawn
S2 1,000 Withdrawn
P-S2V-60 N 48 Withdrawn
S2-20 MD 48 Withdrawn
P-S2V-20 48 Withdrawn
S2V-20 N 48 Withdrawn
P-S2V-60 48 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
ICU Medical ICU Medical, Inc 529
Codan Codan US Corp. 510
Vygon Vygon Corp. 355
Port Access Needle Bard Access Systems, Inc. 341
Set, Administration, Intravascular Mps Medical, Inc. 291
Alaris, SmartSite BD Switzerland Sàrl 266
IV Administration Set B. Braun Medical Inc. 242
Medex ICU Medical, Inc 237
Extension Set B. Braun Medical Inc. 171
MaxGuard BD Switzerland Sàrl 150
Medline Medline Industries, Inc. 148
Centurion Centurion Medical Products Corporation 145

Showing 12 of 768. All products under Set, Administration, Intravascular

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-06-19 Class II Nonconforming Material/Component Intravascular (I.V.) fluid administration sets are exhibiting inaccurate or inconsistent flow rates. 1,612,440in total 2022-07-25
2011-04-15 Not classified Mixed-up of materials/components ConMed received complaints of some units exhibiting inaccurate or inconsistent flow rates. It was determined that certain units were assembled with an incorrect component which could result in the devices exhibiting a different flow rate a 2013-01-15
2011-04-15 Not classified Device Design ConMed received 16 complaints for STAT 2 Pumpette devices for inaccurate flow rates and for leakage from the body of the compensating controller. The investigation of the complaints determined that the STAT 2 Pumpette Compensating Controll 1,146,741 sets in total 2012-11-20
2011-04-15 Not classified Device Design ConMed received 16 complaints for STAT 2 Pumpette devices for inaccurate flow rates and for leakage from the body of the compensating controller. The investigation of the complaints determined that the STAT 2 Pumpette Compensating Controll 1,146,741 sets in total 2012-11-20
2011-04-15 Not classified Mixed-up of materials/components ConMed received complaints of some units exhibiting inaccurate or inconsistent flow rates. It was determined that certain units were assembled with an incorrect component which could result in the devices exhibiting a different flow rate a 2013-01-15
2011-04-15 Not classified Mixed-up of materials/components ConMed received complaints of some units exhibiting inaccurate or inconsistent flow rates. It was determined that certain units were assembled with an incorrect component which could result in the devices exhibiting a different flow rate a 2013-01-15
2011-04-15 Not classified Device Design ConMed received 16 complaints for STAT 2 Pumpette devices for inaccurate flow rates and for leakage from the body of the compensating controller. The investigation of the complaints determined that the STAT 2 Pumpette Compensating Controll 1,146,741 sets in total 2012-11-20
2011-04-15 Not classified Device Design ConMed received 16 complaints for STAT 2 Pumpette devices for inaccurate flow rates and for leakage from the body of the compensating controller. The investigation of the complaints determined that the STAT 2 Pumpette Compensating Controll 1,146,741 sets in total 2012-11-20
2011-04-15 Not classified Mixed-up of materials/components ConMed received complaints of some units exhibiting inaccurate or inconsistent flow rates. It was determined that certain units were assembled with an incorrect component which could result in the devices exhibiting a different flow rate a 2013-01-15
2011-04-15 Not classified Mixed-up of materials/components ConMed received complaints of some units exhibiting inaccurate or inconsistent flow rates. It was determined that certain units were assembled with an incorrect component which could result in the devices exhibiting a different flow rate a 2013-01-15
2011-04-15 Not classified Device Design ConMed received 16 complaints for STAT 2 Pumpette devices for inaccurate flow rates and for leakage from the body of the compensating controller. The investigation of the complaints determined that the STAT 2 Pumpette Compensating Controll 1,146,741 sets in total 2012-11-20
2011-04-15 Not classified Mixed-up of materials/components ConMed received complaints of some units exhibiting inaccurate or inconsistent flow rates. It was determined that certain units were assembled with an incorrect component which could result in the devices exhibiting a different flow rate a 2013-01-15
2011-04-15 Not classified Mixed-up of materials/components ConMed received complaints of some units exhibiting inaccurate or inconsistent flow rates. It was determined that certain units were assembled with an incorrect component which could result in the devices exhibiting a different flow rate a 2013-01-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer