High Pressure Tubing, Keep™

25 catalogue numbers from 00884450568637, listed by Merit Medical Systems, Inc., United States, under Tubing, Fluid Delivery. 2 manufacturers in China are registered for this product code.

Registry build 21.09.26
2manufacturers in China registered for this device type
25catalogue numbers in this listing
1510(k) clearance
1recall

Who Else Makes It

Concentrated in Shanghai (1), Guangdong (1).

Chinese manufacturers registered for FDA product code FPK
Manufacturer City Province Registered as Device types
Sterigenics Shanghai ETO Ltd. Shanghai Shanghai Contract manufacturer 65
Vincent Medical (Dong Guan) Manufacturing Co., Ltd. Dong Guan Guangdong Contract manufacturer 29

Record

Regulatory record for High Pressure Tubing, Keep™
Listed by Merit Medical Systems, Inc., United States
FDA product code FPK
Device type Tubing, Fluid Delivery
Device class Class 2
Regulation 21 CFR 880.5440
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2022-02-18
Record revised 2025-03-20 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging Pack of 25, pack of 4

Catalogue Numbers

Catalogue numbers for High Pressure Tubing, Keep™
Catalogue number Size Status
00884450568637 Tubing Length (in/cm)-20″ (51 cm) In distribution
00884450569160 Tubing Length (in/cm)-48″ (122 cm) In distribution
00884450046135 Tubing Length (in/cm)-60″ (152 cm) In distribution
C Tubing Length (in/cm)-30″ (76 cm) In distribution
00884450006948 Tubing Length (in/cm)-20″ (51 cm) In distribution
00884450387672 Pressure Rating psi (bar)-1200 psi (83 bar) In distribution
00884450006931 Pressure Rating psi (bar)-1200 psi (83 bar) In distribution
B Pressure Rating psi (bar)-1200 psi (83 bar) In distribution
00884450387719 Pressure Rating psi (bar)-1200 psi (83 bar) In distribution
00884450387634 Tubing Length (in/cm)-48″ (122 cm) In distribution
00884450387696 Pressure Rating psi (bar)-1200 psi (83 bar) In distribution
00884450387559 Pressure Rating psi (bar)-1200 psi (83 bar) In distribution
00884450027967 Pressure Rating psi (bar)-1200 psi (83 bar) In distribution
B Pressure Rating psi (bar)-1200 psi (83 bar) In distribution
00884450027950 Pressure Rating psi (bar)-1200 psi (83 bar) In distribution
B Pressure Rating psi (bar)-1200 psi (83 bar) In distribution
B Tubing Length (in/cm)-30″ (76 cm) In distribution
00884450008034 Tubing Length (in/cm)-72″ (183 cm) In distribution
00884450021439 Pressure Rating psi (bar)-1200 psi (83 bar) In distribution
00884450006924 Pressure Rating psi (bar)-1200 psi (83 bar) In distribution
00884450387665 Tubing Length (in/cm)-60″ (152 cm) In distribution
00884450046142 Tubing Length (in/cm)-60″ (152 cm) In distribution
00884450027974 Tubing Length (in/cm)-72″ (183 cm) In distribution
00884450568705 Pressure Rating psi (bar)-1200 psi (83 bar) In distribution
00884450568651 Tubing Length (in/cm)-20″ (51 cm) In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
High Pressure Tubing Merit Medical Systems, Inc. 68
Vygon Vygon Corp. 67
Medex ICU Medical, Inc 41
Pressure Monitor Tubing Merit Medical Systems, Inc. 21
Medrad® Twist & Go Sterile High Pressure Connector Tubing, 150cm (60in) Bayer Medical Care Inc. 16
Merit Medical® Merit Medical Systems, Inc. 10
Kew Medical Douglas Medical Products, Inc 8
Merit Medical® Argon Critical Care Systems Singapore PTE. Ltd. 5
CIV Emed Technologies Corporation 5
Medrad® Twist & Go Disposable Syringe 150 mL with Quick Fill Tube Bayer Medical Care Inc. 5
Lifeshield ICU Medical, Inc 5
EZ-IV Emed Technologies Corporation 5

Showing 12 of 51. All products under Tubing, Fluid Delivery

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K883718 1989-01-30

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2025-06-05 Class II Process control High pressure tubing may relax over time causing it to partially separate from the connector resulting in a void that can trap air in the line. Use of the affected product may result in the trapped air being introduced into the patient. 8040

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer