185a+ Infant Incubator

The 185A+ Infant Incubator maintains a warmed environment around a newborn during ground or air transport. It circulates temperature-controlled air into a transparent chamber containing the…

Registry build 21.09.26

The 185A+ Infant Incubator maintains a warmed environment around a newborn during ground or air transport. It circulates temperature-controlled air into a transparent chamber containing the infant, helping limit heat loss while the infant is moved to neonatal care.

The operator selects the chamber temperature, and the incubator regulates the warming environment. It can run on external power or an internal rechargeable battery, allowing its temperature-control function to continue during transport.

Transport Use

The system is operated by trained medical technical personnel. It is designed to carry additional neonatal support and monitoring equipment, while airway-management and other auxiliary equipment are supplied according to the transport configuration.

1manufacturer
2catalogue numbers in this listing
7510(k) clearances naming this product code

Who Else Makes It

Registered in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code FPL
Manufacturer City Province Registered as Device types
Amphenol (Changzhou) Connector Systems Co., Ltd. Changzhou Jiangsu Contract manufacturer 4

Record

Regulatory record for 185A+ Infant Incubator
Listed by International Biomedical, Ltd., United States
FDA product code FPL
Device type Incubator, Neonatal Transport
Device class Class 2
Regulation 21 CFR 880.5410
Establishment Complaint-file establishment, Manufacturer
510(k) K103523
Record published 2016-09-27
Record revised 2024-09-19 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries serial number

Catalogue Numbers

Catalogue numbers for 185A+ Infant Incubator
Catalogue number Size Status
185A+ In distribution
185A+ In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Voyager Infant Transport Incubator International Biomedical, Ltd. 2
NxtGen Infant Transport Incubator International Biomedical, Ltd. 2
Reusable Skin Temperature Probes Flexicare Medical Ltd. 2
LMT nomag® IC 1.5 LMT Medical Systems Gmbh 2
Aviator Transport Incubator International Biomedical, Ltd. 2
LMT nomag® IC 3.0 LMT Medical Systems Gmbh 2
Disposable Skin Temperature Probes Flexicare Medical Ltd. 2
Filter Element E(10 pcs/pkg) For V-808/V-850TR/V-80TR Atom Medical Corporation 1
Advanced Transport Incubator Advanced Instrumentations, Inc. 1
V-808 Main Unit Only(120 V) Atom Medical Corporation 1
Oxygen Sensor For V-808 Atom Medical Corporation 1
Isolette TI500 Transport Incubator Draeger Medical Systems, Inc. 1

Showing 12 of 18. All products under Incubator, Neonatal Transport

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K220742 2022-07-15
K103523 2011-05-11
K103525 2011-05-11
K103524 2011-04-15
K103527 2011-04-15
K081399 2008-06-06
K022876 2002-09-11

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker