BD® Alaris™ Pump Module, Model 8100

BD Alaris™ Pump Module, Model 8100 v12.1.2

Registry build 21.09.26
5manufacturers in China registered for this device type
1catalogue number
4510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Shanghai (2), Guangdong (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FRN
Manufacturer City Province Registered as Device types
Sanmina Kunshan Jiangsu Contract manufacturer 15
Dongguan Honfield Precision Parts Co., Ltd. Zhangmutou, Dongguan Guangdong Contract manufacturer 8
JDI Electronics Factory Dongguan Guangdong Contract manufacturer 7
Zyno Electric & Machinery Ltd, Shanghai Shanghai Shanghai Contract manufacturer 1
Sterigenics Shanghai E Beam Ltd. Shanghai Shanghai Contract manufacturer 14

Record

Regulatory record for BD® Alaris™ Pump Module, Model 8100
Listed by CareFusion 303, Inc, United States
FDA product code FRN
Device type Pump, Infusion
Device class Class 2
Regulation 21 CFR 880.5725
Establishment Specification developer, Complaint-file establishment, Manufacturer
Record published 2021-10-08
Record revised 2025-08-12 (version 7)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries serial number
Storage Storage environment atmospheric pressure 50 to 101 KiloPascal; Storage environment temperature -4 to 140 °F; Storage environment humidity 5 to 90 % RH

Catalogue Numbers

Catalogue numbers for BD® Alaris™ Pump Module, Model 8100
Catalogue number Size Status
8100 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Port Access Infusion SET Sb-Kawasumi Laboratories, Inc. 76
Cadd ICU Medical, Inc 56
Flow Control Tubing GO Medical Industries PTY. Ltd. 39
Curlin Administration Set Zevex, Inc. 30
ambIT Summit Medical Products, Inc. 27
Beeline motIV Rex Pj Tech LLC 24
RMS Precision Flow Rate TubingTM Repro-Med Systems, Inc. 24
Medfusion ICU Medical, Inc 24
Volumat™ Line Fresenius Kabi AB 24
Outlook® B. Braun Medical Inc. 21
Alaris CareFusion 303, Inc 19
Alpha Source Battery Alpha Source Inc. 17

Showing 12 of 191. All products under Pump, Infusion

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K243855 2025-04-25
K211218 2023-07-21
K133532 2014-08-21
K110535 2012-03-26

Recalls Naming This Product

3 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of BD® Alaris™ Pump Module, Model 8100
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
CareFusion 303, Inc UDI-DI 2025-11-06 Class II Under Investigation by firm Due to a number of modules flashed with a date and time associated with the daylight savings time (DST) adjustment that may cause connectivity issue with hospital networks. This issue only affects the Interoperability workflow for devices w 189 devices
CareFusion 303, Inc UDI-DI 2025-10-17 Class I Device Design If infusion pump is dropped or severely jarred this may damage the pump module bezel assembly, which can cause under-infusion, over-infusion, unregulated flow, or pump module failure to calibrate; so dropped/jarred pumps should be removed f 2,574,396
CareFusion 303, Inc UDI-DI 2025-07-08 Class I Under Investigation by firm Infusion pump module used with compatible pump infusion sets may perform outside the established performance ranges for flow rate and bolus accuracy, downstream and upstream occlusion time to alarm, and post-occlusion bolos volume. 33,162,680 units total

Recalls

23 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-02-11 Class II Under Investigation by firm Due to product labeling not indicating which Transport Layer Security (TLS) version that must be enabled on hospital network to ensure secure Wi-Fi communication with Point-of-Care Units 1,025,567
2025-07-08 Class I Under Investigation by firm Infusion pump module used with compatible pump infusion sets may perform outside the established performance ranges for flow rate and bolus accuracy, downstream and upstream occlusion time to alarm, and post-occlusion bolos volume. 33,162,680 units total
2025-01-23 Class II Under Investigation by firm Due to User Manual/Direction for Use incorrectly instructing user to leave the safety clamp in the open position when reloading an infusion set. This issue potentially could result in an accidental over infusion if the roller clamp is left 242,098 systems
2024-08-15 Class II Process control Due to affected devices that may have bent female IUI connector and may not be operable and potentially cause delays in the start of the infusion or monitoring. 20145
2024-08-15 Class II Process control Due to affected devices that may have bent female IUI connector and may not be operable and potentially cause delays in the start of the infusion or monitoring. 10460
2024-08-15 Class II Process control Due to affected devices that may have bent female IUI connector and may not be operable and potentially cause delays in the start of the infusion or monitoring. 180
2024-08-15 Class II Process control Due to affected devices that may have bent female IUI connector and may not be operable and potentially cause delays in the start of the infusion or monitoring. 192964
2024-08-15 Class II Process control Due to affected devices that may have bent female IUI connector and may not be operable and potentially cause delays in the start of the infusion or monitoring. 125017 device (finished devices and kits)
2024-05-21 Class II Under Investigation by firm Due to a software issue the PC unit may not connect to the server which could impact wireless data transmission to and from the server. 168 software version
2023-09-15 Class I Under Investigation by firm Alaris PCA Module 8120, Patient Controlled Analgesia infusion pump: compatible syringes labeling contains syringes that have not been validated. 86,393 units
2023-09-15 Class I Under Investigation by firm Alaris PCA Module 8120, Patient Controlled Analgesia infusion pump: compatible syringes labeling contains syringes that have not been validated. 133,727 units
2023-09-15 Class I Under Investigation by firm Alaris PCA Module 8120, Patient Controlled Analgesia infusion pump: compatible syringes labeling contains syringes that have not been validated. 867,362 units
2023-01-24 Class II Software Design Change Infusion pump PCs with specific software/network cards/IP addresses can have network/wireless connection failure. Could cause inability to receive new datasets and inability to transfer retrospective analytics data to connected systems. Use 83,185
2021-03-03 Class I Process design Pump Module keypad lifting, and Fluid ingress could result in 1) Unresponsive keys: module continues infusion, PC unit will not alarm and must be used for programming changes, may necessitate a different Pump Module. May result in infusion 160300
2020-08-04 Class I Device Design Pump Module keypad may exhibit keys that are unresponsive or stuck as a result of fluid ingress potentially resulting in a delay to the start of infusion or interruption of infusion. Delays in an infusion or interruption can cause serious i 248,519
2020-08-04 Class I Component design/selection The Alaris PC unit can display incorrect syringe type and/or syringe sizes. This could result in delays in infusion, under-infusion, or over-infusion. 180,186 parts & devices
2020-08-04 Class I Reprocessing Controls The pump module keypad may exhibit keys that are unresponsive or stuck as a result of fluid ingress potentially resulting in a delay to the start of infusion, interruption of infusion, or inability to titrate medication. For high-risk pati 313740
2020-08-04 Class I Reprocessing Controls The pump module keypad may exhibit keys that are unresponsive or stuck as a result of fluid ingress potentially resulting in a delay to the start of infusion, interruption of infusion, or inability to titrate medication. For high-risk pati 28346
2020-06-30 Class I Nonconforming Material/Component If one or more screws or washers are loose or missing causing the battery not to be properly secured to the PC Unit, that is running on battery power, the system may experience a power loss with a prolonged, non-silenceable alarm. Power los 824277 2024-04-22
2020-06-30 Class I Device Design Broken elements on pump module platen such as broken upper hinge post, lower hinge, and membrane frame can occur when the door is forcefully closed on an object, the device is dropped, or if improper cleaners are used on the membrane frame 1093588 2024-04-23
2020-06-30 Class II Device Design LED display, which provides infusion or patient monitoring values, on the module may have segments that appear dim. 1442097
2020-06-30 Class II Device Design LED display, which provides infusion or patient monitoring values, on the module may have segments that appear dim. 89497
2020-06-30 Class I Device Design Cleaning agents may damage Inter-Unit Interface (IUI) Connectors, which may lead to interruption of communication or power between PC Unit and modules, which may result in an infusion that stops with a CHANNEL DISCONNECTED message, and an a 37141 2024-04-22
2020-06-30 Class II Device Design LED display, which provides infusion or patient monitoring values, on the module may have segments that appear dim. 130612
2020-06-30 Class I Device Design Cleaning agents may damage Inter-Unit Interface (IUI) Connectors, which may lead to interruption of communication or power between PC Unit and modules, which may result in an infusion that stops with a CHANNEL DISCONNECTED message, and an a 83532 2024-04-22
2020-06-30 Class I Nonconforming Material/Component If one or more screws or washers are loose or missing causing the battery not to be properly secured to the PC Unit, that is running on battery power, the system may experience a power loss with a prolonged, non-silenceable alarm. Power los 37141 2024-04-22
2020-06-30 Class I Device Design Cleaning agents may damage Inter-Unit Interface (IUI) Connectors, which may lead to interruption of communication or power between PC Unit and modules, which may result in an infusion that stops with a CHANNEL DISCONNECTED message, and an a 824277 2024-04-22
2020-06-30 Class II Device Design LED display, which provides infusion or patient monitoring values, on the module may have segments that appear dim. 8558
2020-06-30 Class I Device Design Cleaning agents may damage Inter-Unit Interface (IUI) Connectors, which may lead to interruption of communication or power between PC Unit and modules, which may result in an infusion that stops with a CHANNEL DISCONNECTED message, and an a 122423 2024-04-22
2020-06-30 Class I Device Design Cleaning agents may damage Inter-Unit Interface (IUI) Connectors, which may lead to interruption of communication or power between PC Unit and modules, which may result in an infusion that stops with a CHANNEL DISCONNECTED message, and an a 1332354 2024-04-22
2020-06-30 Class I Device Design Cleaning agents may damage Inter-Unit Interface (IUI) Connectors, which may lead to interruption of communication or power between PC Unit and modules, which may result in an infusion that stops with a CHANNEL DISCONNECTED message, and an a 7854 2024-04-22
2020-06-30 Class I Device Design Cleaning agents may damage Inter-Unit Interface (IUI) Connectors, which may lead to interruption of communication or power between PC Unit and modules, which may result in an infusion that stops with a CHANNEL DISCONNECTED message, and an a 38982 2024-04-22
2020-06-30 Class II Device Design LED display, which provides infusion or patient monitoring values, on the module may have segments that appear dim. 40671
2020-06-30 Class I Device Design Cleaning agents may damage Inter-Unit Interface (IUI) Connectors, which may lead to interruption of communication or power between PC Unit and modules, which may result in an infusion that stops with a CHANNEL DISCONNECTED message, and an a 17767 2024-04-22
2020-02-04 Class I Device Design 1)Error 255-XX-XXX results in inability to edit settings 2)Delay options programming may result in no KVO rate/therapy interruption 3)Software errors results in no low battery alarm/infusion stopping 4)Medium priority KVO/End of Infusion al 870070
2020-02-04 Class I Device Design 1)Error 255-XX-XXX results in inability to edit settings 2)Delay options programming may result in no KVO rate/therapy interruption 3)Software errors results in no low battery alarm/infusion stopping 4)Medium priority KVO/End of Infusion al 83015
2020-02-04 Class I Device Design 1)Error 255-XX-XXX results in inability to edit settings 2)Delay options programming may result in no KVO rate/therapy interruption 3)Software errors results in no low battery alarm/infusion stopping 4)Medium priority KVO/End of Infusion al 114835

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer