BG 323 Pump

Catalogue number 100-603XSA, listed by CME America, LLC, under Pump, Infusion. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
1catalogue number
10recalls on this code

Who Else Makes It

Concentrated in Shanghai (2), Guangdong (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FRN
Manufacturer City Province Registered as Device types
Sanmina Kunshan Jiangsu Contract manufacturer 15
Dongguan Honfield Precision Parts Co., Ltd. Zhangmutou, Dongguan Guangdong Contract manufacturer 8
JDI Electronics Factory Dongguan Guangdong Contract manufacturer 7
Zyno Electric & Machinery Ltd, Shanghai Shanghai Shanghai Contract manufacturer 1
Sterigenics Shanghai E Beam Ltd. Shanghai Shanghai Contract manufacturer 14

Record

Regulatory record for BG 323 Pump
Listed by CME America, LLC
FDA product code FRN
Device type Pump, Infusion
Device class Class 2
Regulation 21 CFR 880.5725
Record published 2016-09-15
Record revised 2022-07-04 (version 6)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Storage environment temperature -13 to 122 °F
Distribution end date 2020-10-15

Catalogue Numbers

Catalogue numbers for BG 323 Pump
Catalogue number Size Status
100-603XSA Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Port Access Infusion SET Sb-Kawasumi Laboratories, Inc. 76
Cadd ICU Medical, Inc 56
Flow Control Tubing GO Medical Industries PTY. Ltd. 39
Curlin Administration Set Zevex, Inc. 30
ambIT Summit Medical Products, Inc. 27
Beeline motIV Rex Pj Tech LLC 24
RMS Precision Flow Rate TubingTM Repro-Med Systems, Inc. 24
Medfusion ICU Medical, Inc 24
Volumat™ Line Fresenius Kabi AB 24
Outlook® B. Braun Medical Inc. 21
Alaris CareFusion 303, Inc 19
Alpha Source Battery Alpha Source Inc. 17

Showing 12 of 191. All products under Pump, Infusion

Recalls

2 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-07-30 Class II Other Multiple reasons:
1) Due to wear and tear of pump motor block mechanism – may cause under infusion situations without the pump alarm being generated.
2) Due to cracks, pump hardware may be damaged by fluid used during the cleaning process.
Total pumps = 4,182 (all models) 2022-03-08
2020-07-30 Class II Other Multiple reasons:
1) Due to wear and tear of pump motor block mechanism – may cause under infusion situations without the pump alarm being generated.
2) Due to cracks, pump hardware may be damaged by fluid used during the cleaning process.
Total pumps = 4,182 (all models) 2022-03-08
2020-07-30 Class II Other Multiple reasons:
1) Due to wear and tear of pump motor block mechanism – may cause under infusion situations without the pump alarm being generated.
2) Due to cracks, pump hardware may be damaged by fluid used during the cleaning process.
Total pumps = 4,182 (all models) 2022-03-08
2020-07-30 Class II Other Multiple reasons:
1) Due to wear and tear of pump motor block mechanism – may cause under infusion situations without the pump alarm being generated.
2) Due to cracks, pump hardware may be damaged by fluid used during the cleaning process.
Total pumps = 4,182 (all models) 2022-03-08
2020-07-30 Class II Other Multiple reasons:
1) Due to wear and tear of pump motor block mechanism – may cause under infusion situations without the pump alarm being generated.
2) Due to cracks, pump hardware may be damaged by fluid used during the cleaning process.
Total Pumps = 4,182 (all models) 2022-03-08
2020-07-30 Class II Other Multiple reasons:
1) Due to wear and tear of pump motor block mechanism – may cause under infusion situations without the pump alarm being generated.
2) Due to cracks, pump hardware may be damaged by fluid used during the cleaning process.
Total pumps = 4,182 (all models) 2022-03-08
2020-02-27 Class II Employee error The wall charger may not properly charge the infusion pump battery. 27 chargers 2022-01-26
2020-01-07 Class I Device Design Infusion Pump Systems may have a delivery inaccuracy of up to 13%, which may result in 1) faster than expected drug delivery when infusing at a very low rate (0.1 mL/h), or 2) slower than expected drug delivery when infusing at high flow ra 30,596 pumps 2022-04-14
2019-09-16 Class I Nonconforming Material/Component When using a specific tubing set with infusion pump system, may result in under deliver of fluids. 69400 infusion sets 2022-04-13
2015-01-16 Class II Software design CME America is recalling the BodyGuard and BodyGuard 323 Infusion pumps due to the potential for an over delivery. 3,186 2017-03-31

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer