Ivenix, Inc.

Large Volume Pump (LVP) Software (order 1 per pump), version 2.0

Registry build 21.09.26
5manufacturers in China registered for this device type
3catalogue numbers in this listing
3510(k) clearances naming this product code

Who Else Makes It

Concentrated in Shanghai (2), Guangdong (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FRN
Manufacturer City Province Registered as Device types
Sanmina Kunshan Jiangsu Contract manufacturer 15
Dongguan Honfield Precision Parts Co., Ltd. Zhangmutou, Dongguan Guangdong Contract manufacturer 8
JDI Electronics Factory Dongguan Guangdong Contract manufacturer 7
Zyno Electric & Machinery Ltd, Shanghai Shanghai Shanghai Contract manufacturer 1
Sterigenics Shanghai E Beam Ltd. Shanghai Shanghai Contract manufacturer 14

Record

Regulatory record for Ivenix, Inc.
Listed by Fresenius Kabi AB, Sweden
FDA product code FRN
Device type Pump, Infusion
Device class Class 2
Regulation 21 CFR 880.5725
Establishment Contract manufacturer, Contract steriliser, Manufacturer
Record published 2020-08-06
Record revised 2023-08-21 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number, serial number
Distribution end date 2021-03-03

Catalogue Numbers

Catalogue numbers for Ivenix, Inc.
Catalogue number Size Status
BKT-0004 In distribution
2.0 Withdrawn
LVP-0003 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Port Access Infusion SET Sb-Kawasumi Laboratories, Inc. 76
Cadd ICU Medical, Inc 56
Flow Control Tubing GO Medical Industries PTY. Ltd. 39
Curlin Administration Set Zevex, Inc. 30
ambIT Summit Medical Products, Inc. 27
Beeline motIV Rex Pj Tech LLC 24
RMS Precision Flow Rate TubingTM Repro-Med Systems, Inc. 24
Medfusion ICU Medical, Inc 24
Volumat™ Line Fresenius Kabi AB 24
Outlook® B. Braun Medical Inc. 21
Alaris CareFusion 303, Inc 19
Alpha Source Battery Alpha Source Inc. 17

Showing 12 of 191. All products under Pump, Infusion

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K210074 2022-03-01
K210073 2022-03-01
K121613 2013-05-01

Recalls Naming This Product

10 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of Ivenix, Inc.
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Fresenius Kabi USA, LLC UDI-DI 2026-05-06 Class I Software design (manufacturing process) Potential software anomaly that can cause the pump to report a false battery-health value (typically 69%) and trigger a battery-depletion alarm that will shut down the pump unless it is reconnected to AC mains power. 32 systems
Fresenius Kabi USA, LLC UDI-DI 2025-11-21 Class II Use error Emphasizing instructions for LVP duration programming located in the IFU. 30 units
Fresenius Kabi USA, LLC UDI-DI 2025-11-14 Class I Software design Software version 5.10.1 and earlier contain anomalies that have the potential to cause serious patient harm or death. 30 units
Fresenius Kabi USA, LLC UDI-DI 2025-01-10 Class I Software Design Change Large Volume Pump Software, version 5.9.2 and earlier has potential for the following anomalies:
1. The pump may become nonfunctional if during an alarm condition the Pause Audio option is repeated 70 time or more.
2. If a secondary infus
23 systems
Fresenius Kabi USA, LLC UDI-DI 2024-08-30 Class I Software design The software has anomalies that have the potential to cause alarms, nonfunctioning pump, or unresponsive screen while continuing therapy. These could cause serious patient harm or death. 17 units
Fresenius Kabi USA, LLC UDI-DI 2024-03-07 Class I Software Design Change Software has anomalies that have the potential to cause underdose, overdose, or delay in therapy which could lead to serious patient harm or death. 17 units
Fresenius Kabi USA, LLC UDI-DI 2023-05-10 Class II Software design Retroactively reported corrections from 2023: 1) A software defect may cause an incorrect (Fail-Stop) alarm when an administration set is loaded or coupled while the pump is executing the power-up sequence. May lead to delay in therapy. 2) 6 US
Fresenius Kabi USA, LLC UDI-DI 2022-09-16 Class II Software design Retroactively reported correction from 2022: A software defect may cause an incorrect (Fail-Stop) Alarm when an administration set is loaded with an upstream occlusion present, resulting in a non-recoverable (Fail-Stop) Pump Problem alarm. 3
Fresenius Kabi USA, LLC UDI-DI 2022-09-08 Class I Software design The display screen may become frozen and unresponsive to user input, triggering an alarm that is evidenced by a buzzer sound and flashing red LEDs as a secondary notification. However, as the screen goes blank it does not indicate an alarm 4 instances 2024-09-10
Fresenius Kabi USA, LLC UDI-DI 2022-04-22 Class II Device Design Start-up time for the flow rate range greater than 50 ml/hr, and less than 200 ml/hr may exceed the specified 6 minutes, depending on the characteristics of air bubble entrapment within the Intermediate Pumping Chamber (IPC) of the administ 1344 pumps

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer