Ivenix Infusion System

Large Volume Pump (LVP) Software (order 1 per pump), version 5.0.0

Registry build 21.09.26
5manufacturers in China registered for this device type
7catalogue numbers in this listing
3510(k) clearances naming this product code

Who Else Makes It

Concentrated in Shanghai (2), Guangdong (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FRN
Manufacturer City Province Registered as Device types
Sanmina Kunshan Jiangsu Contract manufacturer 15
Dongguan Honfield Precision Parts Co., Ltd. Zhangmutou, Dongguan Guangdong Contract manufacturer 8
JDI Electronics Factory Dongguan Guangdong Contract manufacturer 7
Zyno Electric & Machinery Ltd, Shanghai Shanghai Shanghai Contract manufacturer 1
Sterigenics Shanghai E Beam Ltd. Shanghai Shanghai Contract manufacturer 14

Record

Regulatory record for Ivenix Infusion System
Listed by Fresenius Kabi AB, Sweden
FDA product code FRN
Device type Pump, Infusion
Device class Class 2
Regulation 21 CFR 880.5725
Establishment Contract manufacturer, Contract steriliser, Manufacturer
510(k) K183311
Record published 2023-08-07
Record revised 2023-08-21 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number, serial number
Storage Special storage condition: Provided in the IFU
Distribution end date 2023-07-19

Catalogue Numbers

Catalogue numbers for Ivenix Infusion System
Catalogue number Size Status
030-0028-07 In distribution
030-0028-06 In distribution
5.0.0 In distribution
030-0028-08 In distribution
LVP-0004 In distribution
3.0.0 In distribution
030-0028-06 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Port Access Infusion SET Sb-Kawasumi Laboratories, Inc. 76
Cadd ICU Medical, Inc 56
Flow Control Tubing GO Medical Industries PTY. Ltd. 39
Curlin Administration Set Zevex, Inc. 30
ambIT Summit Medical Products, Inc. 27
Beeline motIV Rex Pj Tech LLC 24
RMS Precision Flow Rate TubingTM Repro-Med Systems, Inc. 24
Medfusion ICU Medical, Inc 24
Volumat™ Line Fresenius Kabi AB 24
Outlook® B. Braun Medical Inc. 21
Alaris CareFusion 303, Inc 19
Alpha Source Battery Alpha Source Inc. 17

Showing 12 of 191. All products under Pump, Infusion

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K210074 2022-03-01
K210073 2022-03-01
K121613 2013-05-01

Recalls Naming This Product

21 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Ivenix Infusion System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Fresenius Kabi USA, LLC 510(k) number 2026-05-06 Class I Software design (manufacturing process) Potential software anomaly that can cause the pump to report a false battery-health value (typically 69%) and trigger a battery-depletion alarm that will shut down the pump unless it is reconnected to AC mains power. 32 systems
Fresenius Kabi USA, LLC 510(k) number 2026-05-06 Class I Device Design Fresenius Kabi has been made aware via customer complaints that dropping or severe jarring of the Ivenix LVP may cause damage to internal components that may not be apparent or readily visible and the devices therefore remained in service. 18,444
Fresenius Kabi USA, LLC 510(k) number 2026-02-04 Class II Device Design Potential for the Cassette Loading Lever to break. 18,444 installed bases
Fresenius Kabi USA, LLC 510(k) number 2025-11-21 Class II Use error Emphasizing instructions for LVP duration programming located in the IFU. 30 units
Fresenius Kabi USA, LLC 510(k) number 2025-11-14 Class I Software design Software version 5.10.1 and earlier contain anomalies that have the potential to cause serious patient harm or death. 30 units
Fresenius Kabi USA, LLC 510(k) number 2025-11-03 Class I Process control Incorrect assembly of specific lot of LVP Primary Administration Set that could result in serious patient injury. 483 cases (12,075 eaches)
Fresenius Kabi USA, LLC 510(k) number 2025-11-03 Class II Labeling design Downstream Occlusion alarms may occur during procedures using low flow infusion rates when a check valve* is added to the Ivenix Administration Set. 15,862 units
Fresenius Kabi USA, LLC 510(k) number 2025-09-03 Class II Process change control Potential issue that can cause the device to register “phantom” touches in the lower-left corner of the touchscreen during operation. 6 units
Fresenius Kabi USA, LLC 510(k) number 2025-06-24 Class II Process design Potential for external cassette leaks 19,225 units
Fresenius Kabi USA, LLC 510(k) number 2025-06-24 Class II Process design Potential for external cassette leaks 14,280 units
Fresenius Kabi USA, LLC 510(k) number 2025-06-24 Class II Process design Potential for external cassette leaks 35,925 units
Fresenius Kabi USA, LLC 510(k) number 2025-06-24 Class II Process design Potential for external cassette leaks 348,150 units
Fresenius Kabi USA, LLC 510(k) number 2025-01-10 Class I Software Design Change Large Volume Pump Software, version 5.9.2 and earlier has potential for the following anomalies:
1. The pump may become nonfunctional if during an alarm condition the Pause Audio option is repeated 70 time or more.
2. If a secondary infus
23 systems
Fresenius Kabi USA, LLC 510(k) number 2024-12-06 Class I Process control Potential pneumatic valve failure that may cause the LVP to stop an active infusion and/or could prevent the pump from being used. 1,520 units
Fresenius Kabi USA, LLC 510(k) number 2024-08-30 Class I Software design The software has anomalies that have the potential to cause alarms, nonfunctioning pump, or unresponsive screen while continuing therapy. These could cause serious patient harm or death. 17 units
Fresenius Kabi USA, LLC 510(k) number 2024-03-07 Class I Software Design Change Software has anomalies that have the potential to cause underdose, overdose, or delay in therapy which could lead to serious patient harm or death. 17 units
Fresenius Kabi USA, LLC 510(k) number 2023-11-29 Class I Process change control The device may experience mechanical interference on the Fluid Valve pins, which will trigger a Pump Problem alarm. The issue may lead to delay or interruption of therapy. Depending on the therapy and duration of delay/interruption, the iss 938 US
Fresenius Kabi USA, LLC 510(k) number 2023-05-10 Class II Software design Retroactively reported corrections from 2023: 1) A software defect may cause an incorrect (Fail-Stop) alarm when an administration set is loaded or coupled while the pump is executing the power-up sequence. May lead to delay in therapy. 2) 6 US
Fresenius Kabi USA, LLC 510(k) number 2023-03-10 Class I Process control Fluid ingress that can cause a loss of electrical funtion and failure of the Set ID Sensory, resulting in the prevention of infusion or halt of infusion. 1,546 units
Fresenius Kabi USA, LLC 510(k) number 2022-09-16 Class II Software design Retroactively reported correction from 2022: A software defect may cause an incorrect (Fail-Stop) Alarm when an administration set is loaded with an upstream occlusion present, resulting in a non-recoverable (Fail-Stop) Pump Problem alarm. 3
Fresenius Kabi USA, LLC 510(k) number 2022-04-22 Class II Device Design Start-up time for the flow rate range greater than 50 ml/hr, and less than 200 ml/hr may exceed the specified 6 minutes, depending on the characteristics of air bubble entrapment within the Intermediate Pumping Chamber (IPC) of the administ 1344 pumps

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker