Medrad® Intego Patient Administration Set
Intego Patient Admin Set (Intego - Patient Administration Set) (60766892)
Who Else Makes It
Concentrated in Shanghai (2), Guangdong (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Dongguan Honfield Precision Parts Co., Ltd. | Zhangmutou, Dongguan | Guangdong | Contract manufacturer | 8 |
| JDI Electronics Factory | Dongguan | Guangdong | Contract manufacturer | 7 |
| Zyno Electric & Machinery Ltd, Shanghai | Shanghai | Shanghai | Contract manufacturer | 1 |
| Sterigenics Shanghai E Beam Ltd. | Shanghai | Shanghai | Contract manufacturer | 14 |
Record
| Listed by | Bayer Medical Care Inc., United States |
|---|---|
| FDA product code | FRN |
| Device type | Pump, Infusion |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5725 |
| Establishment | Contract manufacturer, Remanufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K080297 |
| Record published | 2016-09-24 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Handling environment temperature -20 to 60 °C; Handling environment humidity 0 to 95 % RH; Storage environment temperature 0 to 40 °C; Storage environment humidity 10 to 90 % RH |
| Packaging | Pack of 50, box of 50 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| INT CPS | In distribution | |
| INT CPS | In distribution | |
| INT CPS | In distribution | |
| INT CPS | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Port Access Infusion SET | Sb-Kawasumi Laboratories, Inc. | 76 |
| Cadd | ICU Medical, Inc | 56 |
| Flow Control Tubing | GO Medical Industries PTY. Ltd. | 39 |
| Curlin Administration Set | Zevex, Inc. | 30 |
| ambIT | Summit Medical Products, Inc. | 27 |
| Beeline motIV | Rex Pj Tech LLC | 24 |
| RMS Precision Flow Rate TubingTM | Repro-Med Systems, Inc. | 24 |
| Medfusion | ICU Medical, Inc | 24 |
| Volumat™ Line | Fresenius Kabi AB | 24 |
| Outlook® | B. Braun Medical Inc. | 21 |
| Alaris | CareFusion 303, Inc | 19 |
| Alpha Source Battery | Alpha Source Inc. | 17 |
Showing 12 of 191. All products under Pump, Infusion
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Bayer Medical Care Inc. | 510(k) number | 2016-09-30 | Class II | Process control | The Source Administration Sets (SAS) used with the Medrad Intego PET Infusion System do not meet pressure testing specifications in an occlusion situation when the product is more than one year past manufacturing date. | 165,127 (79,714 units in U.S.) | 2017-03-24 |
Recalls
4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-11-30 | Class II | Under Investigation by firm | Black specks may be present on the packaged needles | 2840 units | |
| 2016-11-07 | Class II | Under Investigation by firm | Bayer has determined that all current Source Administration Sets (SAS) used with the Medrad Intego Pet Infusion System may produce particulates in radiopharmaceutical (RP) vials when the needle is inserted. | 178,982 (86,172 units in U.S.) | 2017-10-18 |
| 2015-11-30 | Class II | Nonconforming Material/Component | The firm’s investigation of the Medrad Intego indicates that the inner diameter of the saline tubing is out of specification and may result in the system failing to position the dose correctly during extraction, potentially leading to a low | 198,598 | 2016-11-18 |
| 2012-04-18 | Class II | Nonconforming Material/Component | Bayer HealthCare is recalling all MEDRAD(R) Continuum MF Infusion System tubing sets (macrobore and microbore), catalog numbers MIK200A, MIL 200B, 3015153, 3015155, 3015156, 3015157, 3015158, 3015159, and 3015161. The firm is initiating th | 1,229 Pumps total | 2015-08-17 |
| 2005-03-22 | Not classified | Other | Customer complaint that a continuum infusion pump was attracted to an MR scanner due to customer not completely engaging the pump into the bracket. | 461 units | 2005-08-17 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.