Medrad® Intego PET Infusion System

System, Intego, INT SYS 200, Rdms, Upgraded (86184486)

Registry build 21.09.26
5manufacturers in China registered for this device type
12catalogue numbers in this listing
6recalls on this code

Who Else Makes It

Concentrated in Shanghai (2), Guangdong (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FRN
Manufacturer City Province Registered as Device types
Sanmina Kunshan Jiangsu Contract manufacturer 15
Dongguan Honfield Precision Parts Co., Ltd. Zhangmutou, Dongguan Guangdong Contract manufacturer 8
JDI Electronics Factory Dongguan Guangdong Contract manufacturer 7
Zyno Electric & Machinery Ltd, Shanghai Shanghai Shanghai Contract manufacturer 1
Sterigenics Shanghai E Beam Ltd. Shanghai Shanghai Contract manufacturer 14

Record

Regulatory record for Medrad® Intego PET Infusion System
Listed by Bayer Medical Care Inc., United States
FDA product code FRN
Device type Pump, Infusion
Device class Class 2
Regulation 21 CFR 880.5725
Establishment Contract manufacturer, Remanufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K100798
Record published 2016-09-24
Record revised 2022-07-04 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Handling environment temperature -20 to 60 °C; Handling environment humidity 5 to 100 % RH; Handling environment atmospheric pressure 57 to 106 KiloPascal

Catalogue Numbers

Catalogue numbers for Medrad® Intego PET Infusion System
Catalogue number Size Status
Intego In distribution
INT VS BLK In distribution
Intego In distribution
Intego In distribution
INT VS GLD In distribution
INT VS GRN In distribution
INT VS VLT In distribution
Intego In distribution
Intego In distribution
INT VS BRN In distribution
INT VS SLV In distribution
INT VS BLU In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Port Access Infusion SET Sb-Kawasumi Laboratories, Inc. 76
Cadd ICU Medical, Inc 56
Flow Control Tubing GO Medical Industries PTY. Ltd. 39
Curlin Administration Set Zevex, Inc. 30
ambIT Summit Medical Products, Inc. 27
Beeline motIV Rex Pj Tech LLC 24
RMS Precision Flow Rate TubingTM Repro-Med Systems, Inc. 24
Medfusion ICU Medical, Inc 24
Volumat™ Line Fresenius Kabi AB 24
Outlook® B. Braun Medical Inc. 21
Alaris CareFusion 303, Inc 19
Alpha Source Battery Alpha Source Inc. 17

Showing 12 of 191. All products under Pump, Infusion

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Medrad® Intego PET Infusion System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Bayer Medical Care Inc. 510(k) number 2022-11-30 Class II Under Investigation by firm Black specks may be present on the packaged needles 2840 units
Bayer Medical Care Inc. 510(k) number 2016-09-30 Class II Process control The Source Administration Sets (SAS) used with the Medrad Intego PET Infusion System do not meet pressure testing specifications in an occlusion situation when the product is more than one year past manufacturing date. 165,127 (79,714 units in U.S.) 2017-03-24
Bayer Medical Care Inc. 510(k) number 2015-11-30 Class II Nonconforming Material/Component The firm’s investigation of the Medrad Intego indicates that the inner diameter of the saline tubing is out of
specification and may result in the system failing to position the dose correctly
during extraction, potentially leading to a low
198,598 2016-11-18

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-11-07 Class II Under Investigation by firm Bayer has determined that all current Source Administration Sets (SAS) used with the Medrad Intego Pet Infusion System may produce particulates in radiopharmaceutical (RP) vials when the needle is inserted. 178,982 (86,172 units in U.S.) 2017-10-18
2012-04-18 Class II Nonconforming Material/Component Bayer HealthCare is recalling all MEDRAD(R) Continuum MF Infusion System tubing sets (macrobore and microbore), catalog numbers MIK200A, MIL 200B, 3015153, 3015155, 3015156, 3015157, 3015158, 3015159, and 3015161. The firm is initiating th 1,229 Pumps total 2015-08-17
2005-03-22 Not classified Other Customer complaint that a continuum infusion pump was attracted to an MR scanner due to customer not completely engaging the pump into the bracket. 461 units 2005-08-17

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer