MiniMed Reservoir
Rsvr MMT-326A 10PK Pdgm 1.8ML 2L 3YR UDI
Who Else Makes It
Concentrated in Shanghai (2), Guangdong (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Dongguan Honfield Precision Parts Co., Ltd. | Zhangmutou, Dongguan | Guangdong | Contract manufacturer | 8 |
| JDI Electronics Factory | Dongguan | Guangdong | Contract manufacturer | 7 |
| Zyno Electric & Machinery Ltd, Shanghai | Shanghai | Shanghai | Contract manufacturer | 1 |
| Sterigenics Shanghai E Beam Ltd. | Shanghai | Shanghai | Contract manufacturer | 14 |
Record
| Listed by | Medtronic Minimed, United States |
|---|---|
| FDA product code | FRN |
| Device type | Pump, Infusion |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5725 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K001828 |
| Record published | 2016-10-03 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Packaging | Ct of 72 |
| Sizes | Total volume 1.8 to 3 ml |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| MMT-326A | Total Volume 1.8 ml | 10 | In distribution |
| MMT-332A | Total Volume 3.0 ml | 10 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Port Access Infusion SET | Sb-Kawasumi Laboratories, Inc. | 76 |
| Cadd | ICU Medical, Inc | 56 |
| Flow Control Tubing | GO Medical Industries PTY. Ltd. | 39 |
| Curlin Administration Set | Zevex, Inc. | 30 |
| ambIT | Summit Medical Products, Inc. | 27 |
| Beeline motIV | Rex Pj Tech LLC | 24 |
| RMS Precision Flow Rate TubingTM | Repro-Med Systems, Inc. | 24 |
| Medfusion | ICU Medical, Inc | 24 |
| Volumat™ Line | Fresenius Kabi AB | 24 |
| Outlook® | B. Braun Medical Inc. | 21 |
| Alaris | CareFusion 303, Inc | 19 |
| Alpha Source Battery | Alpha Source Inc. | 17 |
Showing 12 of 191. All products under Pump, Infusion
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K043600 | 2005-03-29 |
| K040061 | 2004-04-08 |
| K032005 | 2003-08-22 |
| K991936 | 2000-01-18 |
| K991013 | 1999-06-23 |
| K922670 | 1993-09-16 |
| K912458 | 1991-06-24 |
| K895436 | 1990-05-24 |
| K890457 | 1989-03-08 |
| K880623 | 1988-04-21 |
| K874564 | 1988-02-11 |
| K864138 | 1986-12-29 |
| K864517 | 1986-12-12 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Medtronic Minimed | 510(k) number | 2013-07-03 | Class II | Under Investigation by firm | Medtronic is recalling certain lots of Medtronic MiniMed Paradigm Reservoirs MMT-326A (1.8mL) and MMT-332A (3.0mL) used with Medtronic Paradigm insulin pumps because they may have increased risk for leaking. A leak in the reservoir may res | 669,672 units | 2014-01-16 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2015-06-19 | Class II | Under Investigation by firm | Medtronic MiniMed is recalling the MiniMed 620G and 640G insulin pumps because there are certain scenarios where the set Bolus screen will not timeout, which could cause confusion by showing a bolus amount that is no longer appropriate. | 1936 units | 2015-10-02 |
| 2014-06-16 | Class II | Under Investigation by firm | Medtronic MiniMed is recalling the Implantable Insulin Pump because there have been reports of a pump malfunction resulting in the disconnection of the delivery of insulin prior to the end of the 7 year useful life of the device. | 764 units | 2014-09-25 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.