Novum IQ

The Novum IQ Syringe Pump is software controlled Syringe infusion pump system that provides delivery of fluids into a patient in a controlled manner, as identified in 21 CFR 880.5725.

Registry build 21.09.26
5manufacturers in China registered for this device type
7catalogue numbers in this listing
52510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Shanghai (2), Guangdong (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FRN
Manufacturer City Province Registered as Device types
Sanmina Kunshan Jiangsu Contract manufacturer 15
Dongguan Honfield Precision Parts Co., Ltd. Zhangmutou, Dongguan Guangdong Contract manufacturer 8
JDI Electronics Factory Dongguan Guangdong Contract manufacturer 7
Zyno Electric & Machinery Ltd, Shanghai Shanghai Shanghai Contract manufacturer 1
Sterigenics Shanghai E Beam Ltd. Shanghai Shanghai Contract manufacturer 14

Record

Regulatory record for Novum IQ
Listed by Baxter Healthcare Corporation, United States
FDA product code FRN
Device type Pump, Infusion
Device class Class 2
Regulation 21 CFR 880.5725
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K211122
Record published 2025-08-25
Record revised 2025-07-08 (version 3)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries serial number
Storage Storage environment temperature -10 to 49 °C; Storage environment humidity 10 to 80 % RH; Special storage condition: KEEP DRY. KEEP AWAY FROM SUNLIGHT.
Packaging Case

Catalogue Numbers

Catalogue numbers for Novum IQ
Catalogue number Size Status
40700BAXUSD In distribution
40700BAXUSRF In distribution
40800BAXUS In distribution
40700BAXUSRP In distribution
40800BAXUSRP In distribution
40700BAXUS In distribution
40700BAXUSL In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Port Access Infusion SET Sb-Kawasumi Laboratories, Inc. 76
Cadd ICU Medical, Inc 56
Flow Control Tubing GO Medical Industries PTY. Ltd. 39
Curlin Administration Set Zevex, Inc. 30
ambIT Summit Medical Products, Inc. 27
Beeline motIV Rex Pj Tech LLC 24
RMS Precision Flow Rate TubingTM Repro-Med Systems, Inc. 24
Medfusion ICU Medical, Inc 24
Volumat™ Line Fresenius Kabi AB 24
Outlook® B. Braun Medical Inc. 21
Alaris CareFusion 303, Inc 19
Alpha Source Battery Alpha Source Inc. 17

Showing 12 of 191. All products under Pump, Infusion

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K251640 2025-07-28
K251636 2025-07-28
K242390 2024-09-05
K211122 2024-03-29
K230041 2023-03-31
K230022 2023-03-31
K222048 2022-09-06
K211125 2022-08-30
K220417 2022-04-29
K173084 2018-05-11
K133801 2014-05-07
K070125 2007-04-16
K052973 2007-01-25
K040985 2004-11-30
K041738 2004-07-09
K041191 2004-06-25
K010566 2001-05-15
K003616 2000-12-12
K002679 2000-09-18
K002380 2000-09-05
K002211 2000-07-28
K993387 1999-11-01
K961703 1996-07-08
K953098 1995-12-22
K945942 1995-07-10
K940147 1994-04-15
K923224 1994-02-24
K915499 1992-03-06
K915523 1992-02-28
K915522 1992-02-28
K913895 1991-10-21
K905778 1991-07-12
K910934 1991-06-24
K910024 1991-05-31
K911289 1991-05-21
K910428 1991-04-08
K910425 1991-04-01
K910523 1991-03-21
K903343 1990-11-21
K900699 1990-04-10
K891289 1990-02-02
K884505 1989-07-14
K884014 1988-12-12
K880625 1988-04-19
K873746 1988-01-06
K852358 1985-07-05
K830486 1983-04-14
K821069 1982-06-10
K813590 1982-01-28
K813473 1982-01-22
K782034 1979-02-27
K761307 1977-01-06

Recalls Naming This Product

8 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Novum IQ
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Baxter Healthcare Corporation 510(k) number 2026-08-11 Class II Software design A software issue that may occur during a Volume/Time (VOT) multi-syringe infusion when a syringe reaches empty and is replaced while a Volume To Be Infused (VTBI) remains. 14601 units
Baxter Healthcare Corporation 510(k) number 2026-08-11 Class II Software design A software issue that may occur during a Volume/Time (VOT) multi-syringe infusion when a syringe reaches empty and is replaced while a Volume To Be Infused (VTBI) remains. 4 units
Baxter Healthcare Corporation 510(k) number 2025-08-04 Class I Software design (manufacturing process) Baxter Healthcare Corporation is issuing an Urgent Medical Device Correction for the Novum IQ Large Volume Pump (LVP) and Novum IQ Syringe Pump (SP) due to software anomalies that may result in a blank Run screen (LVP and SP) and/or false m 43,922 units
Baxter Healthcare Corporation 510(k) number 2025-08-04 Class I Software design (manufacturing process) Baxter Healthcare Corporation is issuing an Urgent Medical Device Correction for the Novum IQ Large Volume Pump (LVP) and Novum IQ Syringe Pump (SP) due to software anomalies that may result in a blank Run screen (LVP and SP) and/or false m 10,101 units
Baxter Healthcare Corporation 510(k) number 2025-07-14 Class I Device Design Baxter is issuing an Urgent Medical Device Correction for the Novum IQ large volume pump (LVP) due to the potential for underinfusion when transitioning from a flow rate to a higher flow rate that is more than double. (e.g., rate change or 36705 units
Baxter Healthcare Corporation 510(k) number 2025-05-12 Class II Device Design Baxter has identified a design issue which may cause the pump to detect the presence of a syringe flange when no syringe is loaded. When this issue occurs, the pumps ‘user interface becomes stuck on the “Remove Syringe” screen when an infus 8027 units
Baxter Healthcare Corporation 510(k) number 2025-04-24 Class I Device Design There is a potential for the Novum IQ LVP due to the potential for underinfusion following use of the “standby mode” feature or if the device is powered off with the set loaded. 34,524 units
Baxter Healthcare Corporation 510(k) number 2025-03-03 Class II Process control Baxter Healthcare Corporation is issuing an Urgent Medical Device Recall for the Novum IQ syringe pumps listed below due to an incorrectly installed gasket. A gasket failure could lead to potential fluid ingress due to cleaning, or as a res 149 units

Recalls

14 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-01-13 Class II Employee error Pumps were released without full testing being performed, including occlusion alarm testing. 5
2025-11-28 Class II Nonconforming Material/Component Certain pumps have potentially been released from service with defective grease applied to the cam and motor gears. Due to its low viscosity, the defective grease may lead to the device having insufficient lubrication on the cam, which coul 585 units
2025-08-04 Class I Software design (manufacturing process) Baxter Healthcare Corporation is issuing an Urgent Medical Device Correction for the Novum IQ Large Volume Pump (LVP) and Novum IQ Syringe Pump (SP) due to software anomalies that may result in a blank Run screen (LVP and SP) and/or false m 22703 units
2025-07-14 Class II Nonconforming Material/Component Baxter has identified that certain pumps have potentially been released with the grease applied to the cam and motor gears that will break down quickly. The breakdown of the grease will lead to the device having insufficient or ineffective 6 units
2025-02-05 Class I Under Investigation by firm There is the potential for missing motor mounting screws, which may have occurred during the servicing process. 323 units
2025-02-05 Class I Under Investigation by firm There is the potential for missing motor mounting screws, which may have occurred during the servicing process. 66 units
2024-11-19 Class II Process control Devices were identified as released after repair without full testing being performed, which includes flow testing. 1 units
2024-11-19 Class II Process control Devices were identified as released after repair without full testing being performed, which includes flow testing. 1 unit
2024-10-02 Class II Process control The door on the Spectrum IQ Infusion pump may not be able to fully close. 8 units
2024-07-17 Class II Under Investigation by firm The Spectrum WBM may fail to auto-document infusion status information back to the hospital’s Electronic Medical Record (EMR) system. This software issue only impacts customers where the Spectrum V8 or Spectrum IQ infusion system is integra 17,377 units
2024-07-17 Class II Under Investigation by firm The Spectrum WBM may fail to auto-document infusion status information back to the hospital’s Electronic Medical Record (EMR) system. This software issue only impacts customers where the Spectrum V8 or Spectrum IQ infusion system is integra 17,377 units
2024-06-14 Class II Under Investigation by firm Improperly performed testing prior to release 1 unit
2024-04-09 Class II Under Investigation by firm There is a potential for cracks on the mount of the front panel of the device. 9 units
2024-03-20 Class II Nonconforming Material/Component One device was improperly performed testing prior to release from a Service Center. 1 pump
2023-10-13 Class I Under Investigation by firm Baxter is issuing an Urgent Medical Device Correction for the Novum IQ Syringe Pump. Baxter identified that after multiple downstream occlusion alarms, the pump may display an Infusion Complete alarm even though uninfused fluid remains in 2023 units
2023-06-15 Class I Under Investigation by firm A medical device correction is being issued for SIGMA Spectrum Infusion System (V8 Platform) and Spectrum IQ Infusion System with Dose IQ Safety Software infusion pumps due to an increase in reported false upstream occlusion alarms followin 3306 units
2023-06-15 Class I Under Investigation by firm A medical device correction is being issued for SIGMA Spectrum Infusion System (V8 Platform) and Spectrum IQ Infusion System with Dose IQ Safety Software infusion pumps due to an increase in reported false upstream occlusion alarms followin 19861 units
2021-12-29 Class I Device Design There is the potential for reduced or non-delivery of medication, in some cases without alerting the user via pump alarm. This may occur as a result of incorrect administration set setup and/or incomplete resolution of upstream occlusion al 146,502 units
2021-12-29 Class I Device Design There is the potential for reduced or non-delivery of medication, in some cases without alerting the user via pump alarm. This may occur as a result of incorrect administration set setup and/or incomplete resolution of upstream occlusion al 241,304 units
2021-07-07 Class I Software design Software issue: The defect creates a mismatch between linked drug identifiers (IDs) in the Dose IQ user interface (UI) and the binary drug library (BDL) loaded onto the Spectrum IQ pump. 61 units 2024-06-20
2021-06-04 Class I Software design System errors were noted following changes the customers implemented to the configuration of their network and server systems. Gateway Server System performance anomalies resulted in excessive Spectrum IQ pump connectivity errors. 130135 units 2024-09-25
2021-03-19 Class II Device Design Potentially defective component in the AC power adapter which may fail over time. 408 units 2022-07-15
2021-01-06 Class II Under Investigation by firm Battery performance issues related to prolonged storage. 589,704 total units 2026-05-04
2020-11-23 Class II Under Investigation by firm There is a potential software error during programming. 9,353 devices
2020-11-23 Class II Under Investigation by firm There is a potential software error during programming. 140,006 devices
2020-11-23 Class II Under Investigation by firm There is a potential software error during programming. 112,463 devices
2020-11-23 Class II Under Investigation by firm There is a potential software error during programming. 293,926 devices
2020-06-30 Class I Labeling design Baxter is updating the device IFU for safety communication regarding cleaning practices. 9352 units 2024-04-29
2020-06-30 Class I Labeling design Baxter is updating the device IFU for safety communication regarding cleaning practices. 152,539 units 2024-04-29
2020-06-30 Class I Labeling design Baxter is updating the device IFU for safety communication regarding cleaning practices. 146,224 units 2024-04-29
2020-06-30 Class I Labeling design Baxter is updating the device IFU for safety communication regarding cleaning practices. 310,969 units 2024-04-29
2018-06-21 Class II Process control The flow rate test verification was not properly executed for certain Sigma Spectrum infusion pumps prior to release. The testing was performed for less than the required minimum run time. Improperly performed flow rate testing may not iden 158 2019-05-23

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer