Statlock

StatlockTM Stabilization devices (PICC Plus, Pediatric, Teddy Bear Foam Pad, Sliding Post Retainer)

Registry build 21.09.26
33manufacturers in China registered for this device type
74catalogue numbers in this listing
4recalls on this code

Who Else Makes It

Concentrated in Zhejiang (13), Jiangsu (5), Shandong (4). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KMK
Manufacturer City Province Registered as Device types
Hubei V-Medical Products Co., Ltd. Xiantao Hubei Contract manufacturer 46
Zhejiang Longterm Medical Technology Co., Ltd. Huzhou Zhejiang Contract manufacturer 26
Henso Medical (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 19
Hubei Junyan Medical Science & Technology Co., Ltd. Huanggang Hubei Contract manufacturer 5
Shandong Shinrise Medical Supplies Co., Ltd. Zibo Shandong Contract manufacturer 5
Shandong Shinemed Technology Co., Ltd. Zibo Shandong Contract manufacturer 2
Boen Healthcare Co., Ltd. Suzhou Jiangsu Specification developer 263
Zhejiang Lidesen Medical Instrument Co., Ltd. Hangzhou Zhejiang Contract manufacturer 100
Anji Spenq Industrial Co., Ltd. Huzhou Zhejiang Manufacturer 85
Jcmed Tianjin Import AND Export Co., Ltd. Tianjin Tianjin Manufacturer 51
Hangzhou Fushan Medical Appliance Co., Ltd. Hangzhou Zhejiang Contract manufacturer 44
Joykey Industrial (Pinghu) Limited Pinghu Zhejiang Contract manufacturer 43

Showing 12 of 33. All 33 manufacturers in China registered for Device, Intravascular Catheter Securement

Record

Regulatory record for Statlock
Listed by Bard Access Systems, Inc., United States
FDA product code KMK
Device type Device, Intravascular Catheter Securement
Device class Class 1
Regulation 21 CFR 880.5210
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2023-12-13
Record revised 2026-05-18 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date
Storage Storage environment temperature 15 to 30 °C
Packaging Case of 10, shelfpack of 50, shelfpack of 25, pack or inner pack of 25, pack or inner pack of 50, case of 50

Catalogue Numbers

Catalogue numbers for Statlock
Catalogue number Size Per pack Status
DI0120 In distribution
VCDC2 In distribution
10045560 In distribution
S04020010 500 In distribution
VPPPSP In distribution
IVK0120 In distribution
CV0220CE In distribution
VPPDFP In distribution
D10120CE In distribution
SEC2404321 500 In distribution
VNN2 In distribution
IVK0100 In distribution
VUPD1416 In distribution
IVK0129 In distribution
CV0321 In distribution
VDS2 In distribution
IV0520CE In distribution
CV0223 In distribution
VUPD1214 In distribution
IV0631 In distribution
CV0224 In distribution
IVK0115 In distribution
IB0200 In distribution
VCDPC In distribution
IVK0104 In distribution
IV0220 In distribution
NN0300 In distribution
VCDP In distribution
VMPDC In distribution
VIFP4 In distribution
IVK0175 In distribution
IV0630 In distribution
MP0120 In distribution
VPPDFPCE In distribution
IV0528 In distribution
PIC0222 In distribution
IV0634 In distribution
D05000002A 500 In distribution
IVK0105 In distribution
IV0500 In distribution
VPPBFP In distribution
PIC0220 In distribution
CV0226 In distribution
IVK0132 In distribution
CV0220 In distribution
VCDPS In distribution
IV0568 In distribution
VEDC In distribution
IVK0108 In distribution
NN0202 In distribution
NN0400 In distribution
VUPD68 In distribution
IV0636 In distribution
VUPD1012 In distribution
IV0570 In distribution
IV0520 In distribution
IV0632 In distribution
IVK0114 In distribution
VPPCSP In distribution
VCDC In distribution
IV0501 In distribution
VPPBSP In distribution
0684000493 In distribution
VADAC In distribution
5083 1,000 In distribution
VCDPP In distribution
VFS In distribution
VHD In distribution
IV0569 In distribution
NN0201 In distribution
IV0579 In distribution
NN0200 In distribution
0684000472 In distribution
IV0577 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Centurion Centurion Medical Products Corporation 190
CathGrip Argentum Medical, LLC 120
Grip-Lok Tidi Products, LLC 44
3M™ Tegaderm™ 3M Company 33
FlexGRIP Bedal International NV 30
3M™ Tegaderm™ 3M Deutschland GmbH 21
LifeBubble Novonate Inc 15
Clik-FIX Starboard Medical, Inc. 12
DeRoyal Deroyal Industries, Inc. 10
Clik-Fix® B. Braun Medical Inc. 10
Medline Medline Industries, Inc. 9
Bedal Bedal International NV 9

Showing 12 of 97. All products under Device, Intravascular Catheter Securement

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-04-25 Class II Process control StatLockTM IV Premium Catheter Stabilization Device may contain an incorrectly sized retainer clip. 4,500 units 2017-08-21
2016-12-09 Class II Process design Bard Access Systems announces a voluntary field action for the StatLock Catheter Stabilization Devices because some single unit pouches have been released without unique product identifiers (product code, lot number, expiration date, etc.). 30,000 units total 2017-05-26
2016-12-09 Class II Process design Bard Access Systems announces a voluntary field action for the StatLock Catheter Stabilization Devices because some single unit pouches have been released without unique product identifiers (product code, lot number, expiration date, etc.). 14,500 units total 2017-05-26
2013-06-10 Class II Packaging BARD Access Systems is recalling lot JUWJF283 of StatLock CV Plus Stabilization Butterfly Devices due to incorrect pad assembly used during manufacture. The absence of the hydrocolloid strip on the bottom may pose an incremental risk includ 3,875 units. 2014-05-21

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer