Intravia

INTRAVIA Container, 1000 mL Capacity

Registry build 21.09.26
7manufacturers in China registered for this device type
7catalogue numbers in this listing
8510(k) clearances naming this product code
10recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (2), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KPE
Manufacturer City Province Registered as Device types
Ming FAI Industrial (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 17
Yangzhou Xingwei Medical Technology Co., Ltd. Yangzhou Jiangsu Contract manufacturer 5
Wanying Health & Technology (Zhongshan) Co., Ltd. Zhongshan Guangdong Contract manufacturer 3
GRI Medical & Electronic Technology Co., Ltd. Jiaxing Zhejiang Contract manufacturer 71
Ming FAI Enterprise International Co., Ltd. Kowloon Hong Kong Exporter 18
Yangzhou Weideli Trading Co., Ltd. Yangzhou Jiangsu Contract manufacturer 10
Beijing L&Z Medical Technology Development Co., Ltd. Beijing Beijing Manufacturer 2

Record

Regulatory record for Intravia
Listed by Baxter Healthcare Corporation, United States
FDA product code KPE
Device type Container, I.V.
Device class Class 2
Regulation 21 CFR 880.5025
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K964853
Record published 2016-09-24
Record revised 2024-03-19 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number
Storage Special storage condition: Adhere to storage requirements of added medication.
Packaging Pack of 6, case of 8, case of 6, pack of 8

Catalogue Numbers

Catalogue numbers for Intravia
Catalogue number Size Status
2J8003 In distribution
2B8012 In distribution
2B8014 In distribution
2B8019 In distribution
2J8002 In distribution
2B8011 In distribution
2B8013 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
ChemoPlus Cardinal Health 54
Secure® Metrix Company, THE 46
EVA TPN Bags Valmed SRL 45
ChemoPlus Cardinal Health 200, LLC 44
Container, I.V. Metrix Company, THE 27
EcoFLX™ Empty Mixing Container Douglas Medical Products, Inc 22
Cormix Metrix Company, THE 21
PiSA BioPharm Pisa Biopharm Inc. 20
Pinnacle® B. Braun Medical Inc. 20
Apex® B. Braun Medical Inc. 18
Acta Medical Acta Medical, LLC 17
McKesson Mckesson Medical-Surgical Inc. 14

Showing 12 of 59. All products under Container, I.V.

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K111217 2011-06-14
K090096 2009-01-30
K020485 2002-03-12
K983294 1998-11-03
K964853 1997-03-31
K945193 1995-05-12
K932477 1994-06-10
K922214 1993-03-26

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Intravia
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Baxter Healthcare Corporation 510(k) number 2017-07-27 Class II Process control A leak may allow for microbial contamination of the sterile fluid path. 29,088 units 2020-11-03
Baxter Healthcare Corporation 510(k) number 2014-09-16 Class I Equipment maintenance Particulate matter found inside the fluid path. 94,224 2017-06-21
Baxter Healthcare Corporation 510(k) number 2014-09-16 Class I Equipment maintenance Particulate matter found inside the fluid path. 20448 2017-06-21

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-09-12 Class II Process control Potential ability to leak once used for compounding. 158,163 units 2020-11-02
2018-09-12 Class II Process control Potential ability to leak once used for compounding. 281,350 units 2020-11-02
2018-09-12 Class II Process control Potential ability to leak once used for compounding. 110,134 units 2020-11-02
2018-09-12 Class II Process control Potential ability to leak once used for compounding. 136,800 units 2020-11-02
2018-09-12 Class II Process control Potential ability to leak once used for compounding. 456,071 units 2020-11-02
2010-02-15 Not classified Nonconforming Material/Component Routine stability testing of the evacuated container product, along with trending of results, indicates that the pH will exceed the upper specification limit prior to the expiration date of this product. 64,560 units 2012-01-29
2010-02-15 Not classified Nonconforming Material/Component Routine stability testing of the evacuated container product, along with trending of results, indicates that the pH will exceed the upper specification limit prior to the expiration date of this product. 79,308 units 2012-01-29

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer