Modification Kit Phototherapy

Catalogue number 2M30450, listed by Drägerwerk AG & Co. KGaA, Germany, under Unit, Neonatal Phototherapy. 1 manufacturer in China is registered for this product code.

Registry build 21.09.26
1manufacturer
1catalogue number

Who Else Makes It

Registered in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code LBI
Manufacturer City Province Registered as Device types
Amphenol (Changzhou) Connector Systems Co., Ltd. Changzhou Jiangsu Contract manufacturer 4

Record

Regulatory record for modification kit phototherapy
Listed by Drägerwerk AG & Co. KGaA, Germany
FDA product code LBI
Device type Unit, Neonatal Phototherapy
Device class Class 2
Regulation 21 CFR 880.5700
510(k) K954611
Record published 2015-10-24
Record revised 2026-01-12 (version 4)

Specifications

Specifications
MRI safety MR Unsafe
Label carries manufacturing date, serial number
Distribution end date 2026-01-09

Catalogue Numbers

Catalogue numbers for modification kit phototherapy
Catalogue number Size Status
2M30450 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
bili-hut™ Little Sparrows Technologies Inc 33
NeoBLUE blanket LED Phototherapy Natus Medical Denmark ApS 10
neoBLUE Natus Medical Incorporated 9
Bilisoft 2.0 Lumitex, Inc. 4
BiliSoft Phototherapy System Datex-Ohmeda, Inc. 3
Lamp RPI 3
Giraffe Blue Spot PT Lite Datex-Ohmeda, Inc. 2
BiliCocoon™ Nest System Neomedlight 2
BiliCocoon™ Bag System Neomedlight 2
BiliCocoon™ Nest Disposable Neomedlight 2
Unit, Neonatal Phototherapy Bistos Co., Ltd. 2
BiliCocoon™ Bag Pad Neomedlight 2

Showing 12 of 61. All products under Unit, Neonatal Phototherapy

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of modification kit phototherapy
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Draeger Medical Systems, Inc. 510(k) number 2012-07-02 Class II Other A routine internal quality check found that the Drager PT 4000 Phototherapy System is fitted with a 16 Amp rated fuse instead of the specified 1.6 Amp rated fuse. This may mean that the internal fuse would not trip promptly in the event of 65 2013-07-01

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer