Comfortmate Fluid Warmer

Catalogue number FW-200, listed by Nxstage Medical, Inc., United States, under Warmer, Thermal, Infusion Fluid. 1 manufacturer in China is registered for this product code.

Registry build 21.09.26
1manufacturer
1catalogue number
1510(k) clearance

Who Else Makes It

Registered in Guangdong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code LGZ
Manufacturer City Province Registered as Device types
Dongguan BAO Kang Dian ZI KE JI Limited Dongguan Guangdong Contract manufacturer 24

Record

Regulatory record for Comfortmate Fluid Warmer
Listed by Nxstage Medical, Inc., United States
FDA product code LGZ
Device type Warmer, Thermal, Infusion Fluid
Device class Class 2
Regulation 21 CFR 880.5725
Establishment Specification developer, Complaint-file establishment, Manufacturer
Record published 2015-09-01
Record revised 2022-03-22 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Storage environment temperature 0 to 50 °C

Catalogue Numbers

Catalogue numbers for Comfortmate Fluid Warmer
Catalogue number Size Status
FW-200 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Pedigo Products, Inc. Pedigo Products, Inc. 207
Amsco Steris Corporation 38
Level 1 ICU Medical, Inc 26
Skytron warming cabinet Skytron, LLC 24
ThermaCor 1200 Infusion System Smisson-Cartledge Biomedical LLC 11
Astoflo® Plus ECO Stihler Electronic Gmbh 10
enFlow Carefusion 8
Fluido® AirGuard System The Surgical Company International B.V. 7
Smithworks Medical, Inc. Smithworks, Inc. 5
Warming Cabinet Single Compartment Counter-Top Model (Glass Door) Imperial Surgical Ltd. 4
Hang&Go PAC Rand SPA 4
enFlow™ Airlife, Inc. 4

Showing 12 of 159. All products under Warmer, Thermal, Infusion Fluid

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K012832 2001-10-24

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer