Hyperthermia Pump, 120v

The Belmont Hyperthermia Pump raises the temperature of the thoracic or peritoneal cavity by circulating warmed sterile solution through it. The physician selects the treatment protocol and…

Registry build 21.09.26

The Belmont Hyperthermia Pump raises the temperature of the thoracic or peritoneal cavity by circulating warmed sterile solution through it. The physician selects the treatment protocol and target temperature. The system combines pumping and fluid warming for continuous lavage of the cavity.

Microprocessor controls regulate fluid delivery and warming. The system monitors fluid and patient temperatures, line pressure and air in the fluid path. Its touchscreen displays flow rate, total fluid pumped, temperatures, pressure and status information so the operator can follow treatment.

Backup Operation

An internal battery supports transport while pumping and safety monitoring continue. Fluid warming is disabled during battery operation. A separate hardware override protects against unsafe operation if the computer fails.

1manufacturer
1catalogue number
6510(k) clearances naming this product code

Who Else Makes It

Registered in Guangdong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code LGZ
Manufacturer City Province Registered as Device types
Dongguan BAO Kang Dian ZI KE JI Limited Dongguan Guangdong Contract manufacturer 24

Record

Regulatory record for Hyperthermia Pump, 120V
Listed by Belmont Instrument Corp., United States
FDA product code LGZ
Device type Warmer, Thermal, Infusion Fluid
Device class Class 2
Regulation 21 CFR 880.5725
510(k) K152208
Record published 2016-09-23
Record revised 2023-11-08 (version 4)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Hyperthermia Pump, 120V
Catalogue number Size Status
902-00001 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Pedigo Products, Inc. Pedigo Products, Inc. 207
Amsco Steris Corporation 38
Level 1 ICU Medical, Inc 26
Skytron warming cabinet Skytron, LLC 24
ThermaCor 1200 Infusion System Smisson-Cartledge Biomedical LLC 11
Astoflo® Plus ECO Stihler Electronic Gmbh 10
enFlow Carefusion 8
Fluido® AirGuard System The Surgical Company International B.V. 7
Smithworks Medical, Inc. Smithworks, Inc. 5
Warming Cabinet Single Compartment Counter-Top Model (Glass Door) Imperial Surgical Ltd. 4
Hang&Go PAC Rand SPA 4
enFlow™ Airlife, Inc. 4

Showing 12 of 159. All products under Warmer, Thermal, Infusion Fluid

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K152208 2015-09-02
K131519 2013-11-06
K090089 2009-02-12
K070654 2007-06-08
K032778 2003-09-22
K032674 2003-09-16

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Hyperthermia Pump, 120V
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Belmont Medical Technologies 510(k) number 2025-03-31 Class II Process design Potential crack in the female connector located on the Heat Exchanger in the set, which will lead to a fluid leak through the crack during priming of the rapid infuser. 158 sets
Belmont Medical Technologies 510(k) number 2025-03-31 Class II Process design Potential crack in the female connector located on the Heat Exchanger in the set, which will lead to a fluid leak through the crack during priming of the rapid infuser. 208 sets
Belmont Medical Technologies 510(k) number 2025-03-31 Class II Process design Potential crack in the female connector located on the Heat Exchanger in the set, which will lead to a fluid leak through the crack during priming of the rapid infuser. 136 sets

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer