Ranger™

3M™ Ranger™ Irrgation Warming Unit, Model 247, 120V-ENG-E , 1 each, 24700

Registry build 21.09.26
1manufacturer
3catalogue numbers in this listing
1recall

Who Else Makes It

Registered in Guangdong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code LGZ
Manufacturer City Province Registered as Device types
Dongguan BAO Kang Dian ZI KE JI Limited Dongguan Guangdong Contract manufacturer 24

Record

Regulatory record for Ranger™
Listed by 3M Company, United States
FDA product code LGZ
Device type Warmer, Thermal, Infusion Fluid
Device class Class 2
Regulation 21 CFR 880.5725
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
Record published 2016-09-24
Record revised 2026-03-16 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Ranger™
Catalogue number Size Per pack Status
24750 10 In distribution
24700 In distribution
24750 10 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Pedigo Products, Inc. Pedigo Products, Inc. 207
Amsco Steris Corporation 38
Level 1 ICU Medical, Inc 26
Skytron warming cabinet Skytron, LLC 24
ThermaCor 1200 Infusion System Smisson-Cartledge Biomedical LLC 11
Astoflo® Plus ECO Stihler Electronic Gmbh 10
enFlow Carefusion 8
Fluido® AirGuard System The Surgical Company International B.V. 7
Smithworks Medical, Inc. Smithworks, Inc. 5
Warming Cabinet Single Compartment Counter-Top Model (Glass Door) Imperial Surgical Ltd. 4
Hang&Go PAC Rand SPA 4
enFlow™ Airlife, Inc. 4

Showing 12 of 159. All products under Warmer, Thermal, Infusion Fluid

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2025-04-22 Class II Device Design Notice was issued to clarify flow rates related to the inlet fluid temperature. 186,880 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer