Vial Adaptor

Vial Adapter 13mm Long FLL w/25μm filter- VF 5 Pack

Registry build 21.09.26
8manufacturers in China registered for this device type
26catalogue numbers in this listing
5510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Concentrated in Zhejiang (3), Jiangsu (3), Hong Kong (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LHI
Manufacturer City Province Registered as Device types
GRI Medical & Electronic Technology Co., Ltd. Jiaxing Zhejiang Contract manufacturer 71
Suzhou Jinsheng Plastic Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Ming FAI Industrial (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 17
Gcmedica Enterprise Ltd.(Wuxi) Wuxi Jiangsu Contract manufacturer 55
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Ming FAI Enterprise International Co., Ltd. Kowloon Hong Kong Exporter 18
Zhejiang Medtec Medical devices Co., Ltd. Hangzhou Zhejiang Manufacturer 10
Hangzhou Qiantang Longyue Biotechnology Co., Ltd. Hangzhou Zhejiang Manufacturer 7

Record

Regulatory record for Vial Adaptor
Listed by West Pharma. Services IL, Ltd., Israel
FDA product code LHI
Device type Set, I.V. Fluid Transfer
Device class Class 2
Regulation 21 CFR 880.5440
Establishment Specification developer, Manufacturer
510(k) K963583
Record published 2016-05-01
Record revised 2023-06-30 (version 8)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Radiation Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging Pack of 4, pack of 150, pack of 1500, pack of 1300, pack of 40, pack of 432
Distribution end date 2023-06-29

Catalogue Numbers

Catalogue numbers for Vial Adaptor
Catalogue number Size Status
8070315 In distribution
8072045 In distribution
8070106 In distribution
8072004 In distribution
8070202 In distribution
8072003 In distribution
8070109 In distribution
8072005 In distribution
8070110 In distribution
8072103 In distribution
8072109 In distribution
8072104 In distribution
8072035 In distribution
8070308 In distribution
8070002 In distribution
8070211 In distribution
8072030 In distribution
8072118 In distribution
8072113 In distribution
8072043 In distribution
8070209 In distribution
8070311 In distribution
8070301 Withdrawn
8072120 Withdrawn
8070118 Withdrawn
8072116 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Kenaflexx Kentron Healthcare, Inc. 49
Set, I.V. Fluid Transfer Mps Medical, Inc. 27
Vial Adapter West Pharma. Services IL, Ltd. 22
Extension SET MPS Pharma & Medical, Inc. 19
Vial Adapter Medic’up Union Plastic 17
Exactamix Baxter Healthcare Corporation 16
Mix2Vial Transfer Device West Pharma. Services IL, Ltd. 15
Arisure Yukon Medical, LLC 13
ViaLok Yukon Medical, LLC 12
ICU Medical ICU Medical, Inc 12
Codan Codan US Corp. 10
SmartSite Yukon Medical, LLC 10

Showing 12 of 233. All products under Set, I.V. Fluid Transfer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K231071 2024-01-19
K232875 2023-12-14
K230988 2023-12-01
K230464 2023-05-22
K213513 2022-08-31

Recalls

3 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-12-26 Class I Device Design Adverse events have been reported with the use of oxytocin in conjunction with the 13mm Vial2Bag DC in pregnant women. Vial2Bag is recalled due to similarities with 13mm Vial2Bag DC. 4.9 million units 2022-07-20
2018-12-26 Class I Device Design Adverse events have been reported with the use of oxytocin in conjunction with the product in pregnant women. There is a possibility that the device may cause inadequate admixing of drug with the solution in the IV bag. This could lead to 3.9 million units 2022-07-20
2018-12-26 Class I Device Design Adverse events have been reported with the use of oxytocin in conjunction with the 13mm Vial2Bag DC in pregnant women. Vial2Bag DC 20mm is recalled due to similarities with 13mm Vial2Bag DC. 30 million units 2022-07-20
2017-10-06 Class II Process control Medimop is recalling certain lots of this product Vial2Bag DC due to the potential of the IV Port separating from the Via12Bag
DC body during the drug reconstitution I IV Set attachment process.
453,600 units 2024-01-23

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker