NeoMagic
3.0Fr x 60cm Single Lumen PICC, 10cm Tearaway, 0.018 x 80cm guide-wire, 7cm Safety GWI
5manufacturers in China registered for this device type
28catalogue numbers in this listing
Who Else Makes It
Concentrated in Guangdong (3), Zhejiang (1), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Hantech Medical Device Co., Ltd. | Cixi | Zhejiang | Contract manufacturer | 18 |
| Turnxon Precision Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 17 |
| Taijia Medical Electronics (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| Chison Medical Technologies Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 5 |
| Haolang Technology (Foshan) Limited Corporation | Foshan | Guangdong | Contract manufacturer | 6 |
Record
| Listed by | NEO Medical Inc., United States |
|---|---|
| FDA product code | LJS |
| Device type | Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5970 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K953300 |
| Record published | 2016-09-24 |
| Record revised | 2025-07-22 (version 6) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: Keep Away From Sunlight; Special storage condition: Keep Dry |
| Packaging | Case of 10, case of 5 |
| Sizes | Catheter gauge 1.9 to 4 Fr; length 25 to 60 cm; needle gauge 23 G; catheter length 25 to 50 cm; pressure 300 psi |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 3929-2650 | Length 50 cm | In distribution |
| 3029-1660 | Length 60 cm | In distribution |
| 1944-1640 | Length 40 cm | In distribution |
| 3591-1660 | Catheter Gauge 3.5 Fr | In distribution |
| 355-72 | Needle Gauge 23 G | In distribution |
| 3039-1660 | Length 60 cm | In distribution |
| 4029-1660 | Length 60 cm | In distribution |
| 350-01 | Catheter Gauge 2.0 Fr | In distribution |
| 2539-1650 | Length 50 cm | In distribution |
| 1942-1640 | Length 40 cm | In distribution |
| 2525-2650 | Catheter Gauge 2.5 Fr | In distribution |
| 1944-1625 | Length 25 cm | In distribution |
| 1944-1630 | Catheter Gauge 1.9 Fr | In distribution |
| 307-166 | Length 60 cm | In distribution |
| 1946-1625 | Catheter Length 25 cm | In distribution |
| 1946-1640 | Catheter Gauge 1.9 Fr | In distribution |
| 355-70 | Catheter Gauge 1.9 Fr | In distribution |
| 3091-1640 | Pressure 300 psi | In distribution |
| 350-00 | Length 40 cm | In distribution |
| 3539-2660 | Length 60 cm | In distribution |
| 1943-1625 | Length 25 cm | In distribution |
| 3929-2660 | Length 60 cm | In distribution |
| 355-75 | Catheter Gauge 1.9 Fr | In distribution |
| 1944-1650 | Catheter Gauge 1.9 Fr | In distribution |
| 300-166 | Length 60.0 cm | In distribution |
| 360-01 | In distribution | |
| 3043-1660 | Catheter Gauge 3 Fr | In distribution |
| 1943-1640 | Length 40 cm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arrow | Teleflex Medical LLC | 1,548 |
| BioFlo | Navilyst Medical, Inc. | 658 |
| PowerPICC | Bard Access Systems, Inc. | 477 |
| PowerPICC Solo | Bard Access Systems, Inc. | 333 |
| PowerPICC Provena | Bard Access Systems, Inc. | 312 |
| Xcela | Navilyst Medical, Inc. | 271 |
| PRO-Picc® CT | Medical Components Inc | 157 |
| Vascu-Picc® | Medical Components Inc | 135 |
| Turbo-Ject | Cook Incorporated | 94 |
| Cook Spectrum Turbo-Ject | Cook Incorporated | 73 |
| Vascu-Picc®and Midline Catheters | Medical Components Inc | 55 |
| Synergy | Health Line International Corporation | 53 |
Showing 12 of 194. All products under Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.