V-Cath
4.0Fr x 60cm Single Lumen PICC with Stylet and OTN Introducer
5manufacturers in China registered for this device type
9catalogue numbers in this listing
Who Else Makes It
Concentrated in Guangdong (3), Zhejiang (1), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Hantech Medical Device Co., Ltd. | Cixi | Zhejiang | Contract manufacturer | 18 |
| Turnxon Precision Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 17 |
| Taijia Medical Electronics (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| Chison Medical Technologies Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 5 |
| Haolang Technology (Foshan) Limited Corporation | Foshan | Guangdong | Contract manufacturer | 6 |
Record
| Listed by | NEO Medical Inc., United States |
|---|---|
| FDA product code | LJS |
| Device type | Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5970 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K953300 |
| Record published | 2016-09-24 |
| Record revised | 2025-07-22 (version 5) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: Keep Away From Sunlight; Special storage condition: Keep Dry |
| Packaging | Case of 10 |
| Sizes | Length 60 cm; catheter gauge 3 to 5 Fr |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 380-75 | Length 60.0 cm | In distribution |
| 390-76 | Length 60.0 cm | In distribution |
| 380-01 | In distribution | |
| 385-75 | Length 60.0 cm | In distribution |
| 407-166 | Length 60 cm | In distribution |
| 5029-2660 | Length 60.0 cm | In distribution |
| 304-166 | Length 60.0 cm | In distribution |
| 5029-1660 | Length 60.0 cm | In distribution |
| 507-166 | Length 60.0 cm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arrow | Teleflex Medical LLC | 1,548 |
| BioFlo | Navilyst Medical, Inc. | 658 |
| PowerPICC | Bard Access Systems, Inc. | 477 |
| PowerPICC Solo | Bard Access Systems, Inc. | 333 |
| PowerPICC Provena | Bard Access Systems, Inc. | 312 |
| Xcela | Navilyst Medical, Inc. | 271 |
| PRO-Picc® CT | Medical Components Inc | 157 |
| Vascu-Picc® | Medical Components Inc | 135 |
| Turbo-Ject | Cook Incorporated | 94 |
| Cook Spectrum Turbo-Ject | Cook Incorporated | 73 |
| Vascu-Picc®and Midline Catheters | Medical Components Inc | 55 |
| Synergy | Health Line International Corporation | 53 |
Showing 12 of 194. All products under Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.