Dignity® Low Profile CT Port

6.6F Plastic Dignity® LOW Profile CT Port W/Silicone Filled Suture Holes W/PRE- Attached Chronoflex® Polyurethane Catheter W/5F Micro-Stick® Introducer SET

Registry build 21.09.26
2manufacturers in China registered for this device type
45catalogue numbers in this listing
2510(k) clearances naming this product code
8recalls on this code

Who Else Makes It

Concentrated in Guangdong (1), Jiangsu (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LJT
Manufacturer City Province Registered as Device types
Turnxon Precision Co., Ltd. Dongguan Guangdong Contract manufacturer 17
Forefront Medical Technology (Jiangsu) Co., Ltd. Changzhou Jiangsu Contract manufacturer 14

Record

Regulatory record for Dignity® Low Profile CT Port
Listed by Medical Components Inc, United States
FDA product code LJT
Device type Port & Catheter, Implanted, Subcutaneous, Intravascular
Device class Class 2
Regulation 21 CFR 880.5965
Establishment Contract manufacturer, Reprocessor, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2015-10-22
Record revised 2022-07-15 (version 7)

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Packaging Box of 5, box
Distribution end date 2019-11-29

Catalogue Numbers

Catalogue numbers for Dignity® Low Profile CT Port
Catalogue number Size Status
MRCTI66041 In distribution
MRCTI66041BW In distribution
MICTI66841 Withdrawn
MRDP80PLS Withdrawn
MICTI5084S Withdrawn
MIDP80ALS Withdrawn
MICTI8004S Withdrawn
MRDP80PLN Withdrawn
MRCTI50841 Withdrawn
MICTI66041 Withdrawn
MRDP66PLN Withdrawn
MICTI80041 Withdrawn
MICTI6684S Withdrawn
MRDP80ALN Withdrawn
MRCTI6684S Withdrawn
MRCTI80041 Withdrawn
MRDP50ALS Withdrawn
MICTI6604S Withdrawn
MIDP66ALS Withdrawn
MIDP50PLS Withdrawn
MRCTI80841 Withdrawn
MICTI50841 Withdrawn
MIDP50ALS Withdrawn
MICTI50041 Withdrawn
MRCTI5004T Withdrawn
MRDP66ALN Withdrawn
MRCTI8084S Withdrawn
MRCTI6604S Withdrawn
MRDP66PLS Withdrawn
MRCTI8004S Withdrawn
MIDP66PLS Withdrawn
MIDP66ALN Withdrawn
MRDP50PLS Withdrawn
MIDP66PLN Withdrawn
MRCTI50041 Withdrawn
MIDP80PLN Withdrawn
MRDP50PLN Withdrawn
MICTI80841 Withdrawn
MRDP80ALS Withdrawn
MICTI8084S Withdrawn
MRCTI5004S Withdrawn
MRCTI66841 Withdrawn
MRCTI5084S Withdrawn
MRDP66ALS Withdrawn
MRDP50ALN Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Dignity® Medical Components Inc 168
Deltec ICU Medical, Inc 130
NorPort Vascular Access Port Norfolk Medical 106
BioFlo Vortex AngioDynamics, Inc. 60
BioFlo Vortex Navilyst Medical, Inc. 59
Dignity® MID-Sized CT Port Medical Components Inc 55
TidalPort Vascular Access Port Norfolk Medical 52
Pro-Fuse® Low Profile CT Port Medical Components Inc 45
Dignity® Mini CT Port Medical Components Inc 44
Medcomp GEN III Power Injectable Portmedcomp GEN III Power Injectable Port Medical Components Inc 29
PRO-Fuse® Medical Components Inc 28
Xcela Navilyst Medical, Inc. 28

Showing 12 of 96. All products under Port & Catheter, Implanted, Subcutaneous, Intravascular

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K130923 2013-07-31
K120281 2012-09-17

Recalls

6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2021-01-13 Class II Employee error The 5F Dignity CT Port kits were packaged with the incorrect size port. The kits include a 6.6F port instead of the correct 5F port. The inability to connect the catheter lumen to the port stem because of the incorrect size may not be noted 96 pieces total (updated 3/11/2021 additional 72 pieces)
2017-11-22 Class II Mixed-up of materials/components The kit was packaged with the incorrect guidewire. The label indicates the kit contains a marked guidewire. The kits were packaged with an unmarked guidewire. 24 Eaches 2018-07-11
2017-05-25 Class II Mixed-up of materials/components The kit was packaged with the incorrect introducer needle size. The label indicates the kit contains an 18G Needle w/Echo Tip. The kits were packaged with a 21G Needle w/Echo Tip. 65 units 2018-09-04
2017-02-23 Class II Unknown/Undetermined by firm The 9.6F port kits were packaged with the incorrect valved peelable introducer. The label states the kit contains a 10F valved peelable introducer. The kit is packaged with a 9F valved peelable introducer. The port lumen will not fit throug 71 units 2018-02-02
2015-01-28 Class II PMA The dual port with catheters was not covered under FDA clearance. 325 2017-01-06
2012-04-12 Not classified Employee error 50 trays of Dignity Low Profile CT Port were labeled as Dignity Mid-Sized CT Port. 50 trays 2013-07-18
2012-04-02 Class II Packaging process control Product was packaged with the incorrect port and does not match the label. The kit is labeled as an 8F Low Profile Pro-Fuse CT Port. The kit contains an 8F Midsize Dignity CT Port. 30 2013-05-20
2010-07-02 Not classified Employee error Recalled product was packaged with the incorrect port and does not match the label. The kit is labeled as a 6.6F “Dignity” Low Profile CT Port. The kit contains a 6.6F “Pro-Fuse” Low Profile CT Port. 47 units 2010-10-13

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker