Omnipod Go Insulin Delivery Device 35u/day

Catalogue number POD-INS-I1-3525, listed by Insulet Corporation, United States, under Pump, Infusion, Insulin. 7 manufacturers in China are registered for this product code.

Registry build 21.09.26
7manufacturers in China registered for this device type
1catalogue number
13510(k) clearances naming this product code
14recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Guangdong (3), Shanghai (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LZG
Manufacturer City Province Registered as Device types
Sanmina Kunshan Jiangsu Contract manufacturer 15
Providence Enterprise Limited Shenzhen Guangdong Contract manufacturer 9
Flextronics Industrial (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 5
Advance Technology Ltd Shenzhen Guangdong Contract manufacturer 3
Sterigenics Shanghai ETO Ltd. Shanghai Shanghai Contract manufacturer 65
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Viant Medical Suzhou EPZ Co., Ltd. Jiangsu Jiangsu Contract manufacturer 3

Record

Regulatory record for Omnipod Go Insulin Delivery Device 35U/day
Listed by Insulet Corporation, United States
FDA product code LZG
Device type Pump, Infusion, Insulin
Device class Class 2
Regulation 21 CFR 880.5725
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K223372
Record published 2023-08-18
Record revised 2025-12-04 (version 3)

Specifications

Specifications
MRI safety MR Unsafe
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Packaging 5 pack box of 5

Catalogue Numbers

Catalogue numbers for Omnipod Go Insulin Delivery Device 35U/day
Catalogue number Size Status
POD-INS-I1-3525 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
OneTouch Ping Animas Corp. 12
Easy Release Sooil Development Co., Ltd. 9
V-Go Disposable Insulin Delivery Mannkind Corporation 6
Accu-Chek Combo Roche Diabetes Care, Inc. 5
Superline Sooil Development Co., Ltd. 4
t:slim Cartridge, t:lock, 10 Pack Tandem Diabetes Care, Inc. 3
Dana Diabecare Sooil Development Co., Ltd. 3
Accu-Chek Spirit Cartridge Roche Diabetes Care, Inc. 2
t:slim X2 Insulin Pump Tandem Diabetes Care, Inc. 2
Omnipod Insulet Corporation 2
Soft-Release-ST Sooil Development Co., Ltd. 2
t:slim Insulin Pump, Replacement Tandem Diabetes Care, Inc. 1

Showing 12 of 53. All products under Pump, Infusion, Insulin

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K223372 2023-04-24
K211575 2021-08-13
K192659 2019-10-21
K182630 2019-01-08
K180045 2018-06-01
K162296 2017-04-18
K160252 2016-04-27
K140439 2014-11-13
K131294 2013-08-29
K122953 2012-12-07
K111669 2011-12-15
K042792 2005-01-03
K031373 2003-12-19

Recalls

7 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-05-20 Class I Process design External soft cannula damage during manufacturing that results in insulin leaking around the Pod instead of being delivered to the user regardless of basal or bolus delivery. The primary failure mode is pump under-delivery due to loss of in 1,790,784 units
2026-05-20 Class I Process design External soft cannula damage during manufacturing that results in insulin leaking around the Pod instead of being delivered to the user regardless of basal or bolus delivery. The primary failure mode is pump under-delivery due to loss of in 289,046 units
2022-10-17 Class I Device Design The firm has become aware of PDM battery issues, including battery swelling, fluid leaking from the battery, and extreme overheating, which may pose a fire hazard. The firm has received a complaint alleging fire as a result of thermal energ 248,288 US; 167,802 OUS 2024-09-17
2021-02-01 Class II Labeling design Certain foreign user guides include a misprint which could lead to an incorrect bolus delivery and hypoglycemia. Only Outside the US (OUS): Error in the Omnipod DASH User Guide text, page 6 of the User Guide, the text states that the comma 21,723 guides 2023-02-08
2020-04-02 Class II Device Design After the device has been in use for about 2 months, data processing in the PDM can be slowed such that the Bolus Calculator fails to accurately subtract the correct amout of IOB before suggesting a bolus amount. 400 2021-09-14
2020-04-02 Class II Device Design After the device has been in use for about 2 months, data processing in the PDM can be slowed such that the Bolus Calculator fails to accurately subtract the correct amout of IOB before suggesting a bolus amount. 1773 2021-09-14
2020-02-13 Class II Software design In certain scenarios, the Omnipod DASH PDM may suggest an inaccurate bolus amount based on a blood glucose value that is more than 10 minutes old when the user does not exit the bolus calculator as designed or when a system alarm interrupt 32756 (US), 1420 (International) 2021-09-14
2018-12-18 Class II Software design There is a potential for a communication interruption following a bolus command that may result in inaccurate information presented in insulin on board (IOB), last bolus field or bolus history. 264 2020-05-13
2015-11-02 Class I Process change control Pod’s needle mechanism fails to deploy or there is a delay in the deployment of the needle mechanism. 5,179.0 boxes 2017-03-07
2015-11-02 Class I Process change control Pod’s needle mechanism fails to deploy or there is a delay in the deployment of the needle mechanism. 26,230.9 boxes 2017-03-07
2015-07-13 Class I Nonconforming Material/Component OmniPods (Pods) have a higher rate of failure causing:
Cannula fails to deploy/retract causing insulin to be pumped or the audible alarm is displayed on the PDM and pod will not deliver insulin
24829 boxes Expanded: 26,230.9 boxes 2017-01-26
2015-07-13 Class I Nonconforming Material/Component OmniPods (Pods) have a higher rate of failure causing:
Cannula fails to deploy/retract causing insulin to be pumped or the audible alarm is displayed on the PDM and pod will not deliver insulin
16,017 boxes. Expanded Recall: 5,179.0 boxes 2017-01-26
2013-09-27 Class II Labeling design Alcohol Prep Pads contained within the kit are not properly labeled. 5,050 kits 2014-03-04
2013-09-27 Class II Labeling design Alcohol Prep Pads contained within the kit are not properly labeled. 1,719 starter kits 2014-03-04

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer